• 제목/요약/키워드: 응집부상

검색결과 68건 처리시간 0.024초

AOF공정 중 응집제와 오존 농도가 가축분뇨 처리효율에 미치는 영향 (Effects of Coagulants and Ozone Concentration on the Livestock Manure Treatment Efficiency of AOF Process)

  • 정승철;윤린
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.311-315
    • /
    • 2016
  • The efficiency of manure treatment was investigated in terms of the pH, BOD, COD, SS, T-N and TP with a variation in the injection amount of PAC, polymer and ozone. The wastewater flow rate to the AOF is of $7.4m^3/hr$ with a reaction time of 30 minutes. The amount of PAC and polymer changed by 30, 35, 40 ml/min, and 30, 40, 50 ml/min, respectively. The amount of ozone injected varied from 110, 125, and $150kg-O_3/hr$. The optimum manure treatment performance was found for a PAC of 35 ml/min for the COD and SS, with polymer of 30 ml/min, and ozone injection of $150kg-O^3/hr$. A substantially optimum dose for each PAC, polymer, and ozone was also found to exist.

천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성 (Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant)

  • 장여주;정진홍;임현만;장향연;김원재
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.

상하수처리를 위한 새로운 고효율 응집/여과 장치 (A Novel High Rate Flocculator/Filter in Water and Wastewater Treatment)

  • ;;권대영
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.149-154
    • /
    • 2005
  • Conventionally used flocculation tanks require large space and high energy requirement for mixing. Static flocculators using gravel bed filter operate at a lower flow rate ($5-10m^3/m^2{\cdot}h$). Further, the cleaning of this system is difficult. A novel high rate static flocculator/filter developed at UTS packed with buoyant media such as polystyrene, polypropylene has been found to operate at higher filtration rates (30-45 $5-10m^3/m^2{\cdot}h$). They can easily be cleaned with minimal energy. Detailed experiments conducted with an artificial kaolin clay solution show that buoyant media is an excellent static flocculator in producing uniform filterable microflocs (12-15 m) even when it is operated at a high rate of 30-40 m/h. Detailed filtration experiments were conducted in a wastewater treatment plant to treat the biologically treated effluent with a floating media of depth of 120 cm. This filter was able to remove majority of phosphorus and remaining solids. It reduced significantly the fecal coliforms and fecal streptoccoci, thus requiring less amount of chlorine for disinfection. The advantage of this system is the low energy and water requirement for cleaning of filter bed. The periodic backwash adopted 30 seconds air and water and 30 seconds water cleaning every 90 minutes filter operation. Thisis equivalent to 1-2% of filtered water production. Mechanical cleaning system on the other hand, requires very low energy requirement (<1% of filtered water production).

슬러리 양돈분뇨의 최적 고액분리 방안 연구 (A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot)

  • 박성균;최재길;정윤진
    • 유기물자원화
    • /
    • 제8권2호
    • /
    • pp.60-70
    • /
    • 2000
  • 현재 국내에서 처리에 어려움을 겪고 있으며 사회적으로 문제가 되고 있는 양돈 분뇨의 처리중 생물학적 처리를 위한 전처리 공정의 일환으로 비육돈 슬러리 돈사에서 발생하는 분뇨를 대상으로 고액분리에 관한 연구를 수행하였다. 최적의 고액 분리를 위하여 적정 응집제 선정 및 첨가량을 도출하였으며, 현장 규모의 고액 분리 장치를 통하여 규모별 최적 고액 분리 공정을 도출하였다. 이 결과 탈수성 개량을 위한 적정 응집제로는 Polyarcylamide 계열의 양이온 고분자 응집제인 E-851이 적합하였으며, 단위 고형물당 0.24~0.6%가 요구되었다. 본 연구에서 검토된 공정으로는 Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, 고속 Screw Decanter, 저속 Screw Decanter 및 DAF 공정을 조합하여 검토하였다. 그 결과 최적 공정으로는 중 소규모의 1차 고액 분리 공정으로는 Screw Press(응집제 첨가)와 대규모 및 공공처리장 규모에서는 저속 Screw Decanter(응집제 첨가)가 적정 공정으로 도출되었으며 2차 처리 공정으로는 가압부상조가 가장 안정적인 것으로 나타났다. 한편 고액 분리 유무에 따라 수분조절제 및 유기물 부하량 감소는 각각 94.8, 84.7%로 나타났으며 슬러리 양돈분뇨의 정화방안으로는 고액분리가 반드시 필요한 것으로 나타났다.

  • PDF

상수원수의 혼화 및 응집 조건에 따른 DAF pump 장치의 부상분리효율 (Flotation Efficiency of the DAF Pump System for Mixing and Coagulation Conditions in Raw Drinking Water)

  • 안갑환;이창한
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.639-645
    • /
    • 2011
  • This study found that flotation efficiencies for removing algae and micro particles in raw water were optimized on mixing intensity and time of the mixing and flocculation conditions with a continuous DAF system. It is more efficient for mixing intensity at 23.1 $s^{-1}$ and time at 660 s(Gt value : 15246) to float flocculated floc with the raw water in M water treatment plant. Flotation efficiency was more than about 0.9 when operated pressure and A/S ratio were sustained at 5 $kg_f{\cdot}cm^{-2}$ and up to 0.056 $mL{\cdot}mg^{-1}$. The continuous DAF system made by the study could be continuously operated for 20 days and sustained not exceeding 4 NTU with raw water with low turbidity(13.4~9.8 NTU).

고급알코올에 의한 토너의 응집처리가 부유부상 탈묵효과에 미치는 영향 (Effects of Agglomeration of Toner Particles with Fatty Alcohol on Flotation Deinking Efficiency)

  • 허용성;이학래
    • 펄프종이기술
    • /
    • 제36권2호
    • /
    • pp.33-38
    • /
    • 2004
  • Toner particles used in laser and xerographic printing process is fused on paper surface so strongly that they tend not to detach easily from the recylced paper surface during pulping. Furthermore, the removal efficiency of detached toner particles by conventional screening and flotation process has limitation due to the platy shape and large size of detached toner particles. It has been shown that the removal efficiency of toners in the screening process can be increased by agglomerating the toner particles with fatty alcohol. It is not possible, however, to remove small and platy toner particles by screening process. These small and platy toner particles should be removed by flotation process. In this study the effect of fatty alcohol that used for toner agglomeration on flotation efficiency has been examined. It was shown that flotation efficiency decreased when fatty alcohol was used most probably due to its effect of reducing hydrophobicity of toner particles.

환경관련 특허동향 - 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템(주식회사 대성그린테크)

  • 한국환경기술인연합회
    • 환경기술인
    • /
    • 통권324호
    • /
    • pp.86-93
    • /
    • 2013
  • 본 발명은 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템에 관한 것으로서, 더욱 상세하게는 건축물에서 배출되는 오수의 유입량을 제어하면서, 산기장치를 이용하여 상기 오수에 일정량의 에어를 공급하여 슬러지의 침강과 부패방지를 유도하는 유량조정조와, 상기 유량조정조를 거친 오수를 응집 및 침전처리하고 가압부상에의해 슬러지를 처리하는 가압부상조와, 상기 가압부상조를 거친 오수에 포함되어 있는 질소, 인을 처리하는 무산소조와, 상기 무산소조를 거친 오수에 포함되어 있는 유기물을 수처리용 접촉 메디아(DSBB)에 의해 분해하는 생물막조와, 상기 생물막조를 거친 오수를 침전과정을 통해 침전된 슬러지를 외부로 배출하는 침전조와, 상기 침전조를 거친 오수를 분리막에 통과시켜 오수에 포함되어 있는 미생물, 세균등의 미세입자들을 제거하는 분리막조와, 상기 분리막조를 거친 오수에 포함되어 있는 미처리 미세입자를 여과기에 통과시켜 처리하는 여과조와, 상기 여과조를 거친 오수를 오존($O_3$) 또는 UV 살균 처리하는 소독조와, 상기 소독조를 거쳐 최종적으로 처리된 처리수를 일정시간 동안 체류시켰다가 건축물의 중수로 재이용하기 위해 방출시키는 저수조를 포함하여 이루어지는 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템에 관한 것이다.

  • PDF

전기응집-전기부상 2단계 공정을 이용한 TiO2 제거 (TiO2 Removal using Electrocoagulation-electroflotation Two-step Process )

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제32권5호
    • /
    • pp.385-394
    • /
    • 2023
  • There is a need for a method that can effectively remove wastewater containing small-sized particles such as TiO2. In this study, we attempted to remove TiO2 wastewater using electrocoagulation-electroflotation two-step separation. The TiO2 wastewater was effectively removed via batch electrocoagulation-electroflotation separation. However, in the batch process, the simultaneous operation of electrocoagulation and electoflotation was challenging due to the high residual turbidity. In the continuous operation, electrocoagulation and electoflotation reactors were kept separate. The turbidity removal in continuous operation was similar to that in the batch process, nevertheless, the residual Al concentration was high, leading to the conclusion that counterterm ensures against residual Al were necessary.

TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험 (Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment)

  • 이규범;장윤영
    • 환경영향평가
    • /
    • 제28권3호
    • /
    • pp.332-345
    • /
    • 2019
  • 이 연구의 목적은 TPH 또는 $Cr^{6+}$이 함유된 오염 지하수의 처리 가능성을 평가하는 데 있다. 오일과 물의 분리, 용존 공기 부유 (DAF), 응고 및 침전, 모래와 활성탄으로 각각 여과를 위한 실험실 규모 테스트가 수행되었다. 총 40 분간의 분리 시간 동안 오일과 물의 분리 시험을 2 회 실시한 결과 TPH 제거율은 90.2 %였다. 높은 농도의 TPH 샘플에 대한 DAF 테스트의 경우, TPH 제거율은 미세 기포 크기의 변화에 따라 크게 변하지 않았다. 그러나 낮은 TPH 샘플에 대한 테스트는 미세 기포가 작을수록 TPH 제거율이 증가함을 보여준다. DAF 테스트를 위해 응집제를 샘플에 첨가했을 때 TPH 제거율은 12.3 % 증가했다. DAF에 의한 SS 제거율은 $16{\sim}40{\mu}m$에서 97.9 %였으며 미세 기포의 크기가 감소함에 따라 증가했다. 지하수에서 $Cr^{6+}$의 제거를 평가하기 위해 응집 및 침전 시험을 수행했다. $FeSO_4$ 투여량을 증가하였을때 응집 및 침전 공정에서 $Cr^{6+}$ 제거율이 증가하였다. 필터 매체에서 활성탄의 비율이 높을수록 여과공정에서 TPH 제거율이 증가한다. 여과에 의한 SS 제거율은 DAF 공정 시험 결과와 비슷한 96.7 %였다. 여과 과정은 TPH와 SS 농도가 감소하였다. 모래의 크기가 $425{\sim}850{\mu}m$이고 활성탄과 모래의 비율이 50:50일때 최적의 처리효율을 나타냈다.

마이크로 버블 부상 공정에 의한 염료폐수의 색도 제거 (Colour Removal from Dyestuff Wastewater by Micro Bubbles Flotation Process)

  • 김명주;한신호
    • 공업화학
    • /
    • 제33권6호
    • /
    • pp.606-612
    • /
    • 2022
  • 수용액에서 수용성 염료를 소수성 염료로 전환시킨 후 마이크로 버블을 이용한 침전 및 부상응집에 의한 염료를 제거하는 연구를 수행하였다. 양이온성 염료에 음이온 collector를 반응시키며, 또한 음이온성 염료에 양이온 collector를 첨가하여 소수성으로 변환시켰다. 소수성으로 전환된 염료 용액을 회분식 반응기에 저장하여 마이크로 버블을 분사시켜 색을 제거하였다. 염료 용액을 제조하기 위해 Basic Yellow 1 및 Direct Orange 10을 사용하였으며, sodium dodecyl sulfate, oleic acid sodium salt 및 amine류와 같은 음이온 및 양이온 collector를 사용하면 색 제거에 효과적이었으며, 모든 색은 8분 이내에 제거되었다. 색 제거는 collector의 첨가량과 수용액 pH의 영향을 받으며, 염료농도에 비해 극히 소량의 계면활성제를 첨가하였을 경우에는 pH에 의존하였으나, 염료농도와 비슷한 collector 양을 첨가하였을 경우에는 pH에 의존하지 않았음을 알 수 있었다. 그 이유는 collector와 염료가 1:1M로 반응하여 소수성이 완전히 부여되어야 제거됨을 알 수 있었다.