• Title/Summary/Keyword: 응력회복

Search Result 177, Processing Time 0.028 seconds

The effect of varying peripheral bone structure and bone density on the occlusal stress distribution of human premolar regions (사람 소구치부위에서 주위골의 구조 및 밀도변화가 교합력에 의한 치아의 응력분포에 미치는 영향)

  • Suh, Ye-Joon;Shim, June-Sung;Lee, Keun-Woo;Chung, Moon-Kyu;Lee, Ho-Yong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • This study used FEM(Finite Element method) based on micro-CT images to see the effects of occlusal force distribution with varying bone density and structure. the mandibular premolar region from human cadaver, thickness of 10mm was imaged using micro-CT. the cross sectional images were taken every $10{\mu}m$. these were reconstructed and the longitudinal image at the mid point of mesiodistal of the speciman was obtained for the specimen for the FEM. The stress disribution produced by a vertical force at 100N and 100N horizontal were analyzed by MSC Nastran FEM Package. according to the result of this study the occlusal force distribution depends on the structure of cancellus bone and for further information on the occlusal force distribution on the tooth and the surrounding structure requires further studies on cancellus bone structure. CEJ of all model show the highest peak and region whice meet teeth and bone show second high peak. Original model and cortical bone add model show different stress distribution. Stress distribution changed according to bone structures and densities.

A Literature Review on Cracked Teeth (균열치 증후군에 대한 문헌고찰)

  • Cho, Woong-Rae;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.305-316
    • /
    • 2011
  • Cracked teeth are a common problem with incomplete fracture that typically shows pain on biting and temperature stimuli. The most common cause of crack is known to be the masticatory accident. Predisposing factors were aging, old restoration, and iatrogenic stress concentration, etc. Accurate diagnosis is needed for detecting the extent of crack and pulp vitality. There are many diagnostic tools like bite test, direct observation with transillumination, dye penetration, and radiographs. Immediate treatment for pain relief and occlusal adjustment would be needed. Composite resin and bonded amalgam showed favorable prognosis. Moreover, cusp protection is reliable permanent treatment for cracked teeth. The purpose of this article is to review the literature about the prevention, diagnosis, and treatment for cracked teeth.

Fracture Analysis of Implant Components using Scanning Electron Microscope - Part I : Implant Fixture (임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 - Part I: 임플란트 고정체)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.297-309
    • /
    • 2010
  • The objective of the present study was to perform a fracture analysis on fractured implant fixture after use in vivo and make clear the cause & mechanisms of failure. In case of fatigue fracture, the fractured surface represents fatigue striation. Fatigue striation indicate the progression of the crack front under cyclic loading, are characteristic of stage 2 crack growth. The site of crack initiation and stage 1 crack growth were not easily identified in any of the failure, presumably because of the complex microstructural features of the polycrystalline sample. In case of fractured by overload, dimpled or cleavage surface were observed. Using the interpretation of characteristic markings(ratchet mark, fatigue striation, dimple, cleavage et al) in fracture surfaces, failure events containing the crack origin, crack propagation, material deficiency could be understand.

Development of Temper Bead Welding Process for Preemptive Weld Overlay of Alloy 82/182 Welds (Alloy 82/182 용접부의 수명 연장 오버레이를 위한 템퍼비드 용접 공정개발)

  • Byeon, Jin-Gwi;Park, Kwang-Soo
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.16-16
    • /
    • 2009
  • Alloy 82/182로 용접된 원자력 발전소 주기기의 이종 금속 용접부는 장기간 운전 후 응력부식균열(SCC : Stress Corrosion Cracking)에 의한 결함이 나타나게 된다. 2000년대 이후로 원자력 주기기 Alloy 82/182 용접부에서 PWSCC(Primary Water Stress Corrosion Cracking)에 의한 Degradation이 급격히 증가하는 추세를 보이고 있으며, 국내에서도 이와 관련하여 원자력 발전소의 안전성에 대한 Issue 및 대비책에 대한 관심이 고조되고 있다. 이러한 Alloy 600 용접부에 대한 결함을 예방하기 위한 대표적인 기술로써 수명연장 오버레이 기술이 있다. 원자력 주기기 노즐부는 저탄소강으로 제작되어 있으며, 저탄소강에는 제작 시 용접후열처리가 적용된다. 후열처리를 하는 주된 이유는 Tempering을 통해 열영향부의 인성 및 연성의 회복과 강도를 감소시켜 모재와 동등 또는 이 이상의 물성을 갖도록 하는 데 그 목적이 있다. 그러나 수명연장 오버레이의 경우 현장 작업 시에 후열처리가 어렵기 때문에, 이를 대체하기 위한 기술로 템퍼비드 용접을 적용할 경우 후열처리를 면제해 주고 있다. 본 연구에서는 수명연장 오버레이 기술 개발의 일환으로써 저 탄소강에 대한 템퍼비드 용접 기술을 확립하였다. 실험에 사용된 모재는 원자력 주기기의 노즐에 사용되는 SA508 Gr.3 Cl.1을 사용하였으며, 용가재는 Alloy 52 및 52M을 사용하였다. 최적 조건 도출을 위해서 실험 매트릭스를 이용하여 기본 실험을 수행하였으며, 실험에는 자동 GTAW 용접을 적용하였다. 기본 실험을 통해 얻은 최적 조건을 사용하여 PQ 시험을 수행하여 WPS를 확보하였다. 분석은 용접 후 조직 및 경도 시험, 물리시험(인장시험, 굽힘시험 및 충격시험)을 수행하였다.

  • PDF

Finite Element Approach to Investigate the Influence of the Jaw Bone Dimension on the Stress Around the Root Analogue Dental Implant (악골폭경이 치근형 임플란트 인접골에서의 응력에 미치는 영향에 대한 유한요소해석적 연구)

  • Jang, Ji-Man;Lee, Kyu-bok;Lee, Cheong-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.37-53
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the influences of the jaw dimension on the bone stress. Materials and Methods: Root analogue implant of Frialit-2 Synchro model in the jaw bone of various thickness from 8mm to 13mm were modelled axisymmetrically for a series of finite element analyses. As load conditions, non-axisymmetric lateral load of 20N and an oblique load of 50N, as well as an axisymmetric vertical load of 50N were taken into consideration. Results: The cervical area of implant under the axisymmetric load and the base cortical bone under the non axisymmetric load condition were the areas of main concern where the higher level of stress were likely to be obtained. Conclusion: The results indicated that at the two concerned areas drastically different stress distribution could take place as a function of the load conditions. Under the vertical load, the lower level of stress was observed for the narrow jaw bone at the cervical cortical bone whereas stress at the base cortical bone remained virtually unchanged. Under the non axisymmetric load condition, however, the stress at the base cortical bone increased very rapidly as the jaw bone width increased without inducing any significant change in the stress level at the cervical area.

Stress Distribution following Rapid Maxillary Expansion using Different Finite Element Model according to Hounsfield Unit Value in CT Image (CT상의 HU 수치에 따른 유한요소모델을 이용한 RME 사용에 따른 응력분포에 대한 연구)

  • Yoon, Byung-Sun;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.313-326
    • /
    • 2007
  • With rising prevalency of mouth breathing children caused by developing civilization and increasing pollution, there are many maxillary transverse discrepancy patients with undergrowth of maxilla. For improving this, maxillary mid-palatal suture splitting was often performed. The purpose of this study was to analyse the stress distribution on the craniofacial suture and cranium after rapid maxillary expansion by finite element model. The boy(13Y6M) was chosen for taking computed-tomography for finite element model. Three-dimensional model of maxilla, first premolar, first molar, buccal and lingual part of rapid maxillary expansion were constructed. 1. The alveolar bone adjacent to the first molar and the first premolar that was affected directly by rapid maxillary expansion was displaced laterally approximately 4.04mm at maximum. The force decreased toward anterior region and frontal alveolar bone displaced laterally about 3.18mm. 2. A forward maximum displacement was exhibited at zygomatic process middle region. 3. At maximum, maxillary median part experienced 0.973mm downward repositioning and 0.65mm upward repositioning at lateral alveolar bone. 4. Von mises stress was observed the largest stress distribution around teeth and zygomatic buttress. 5. The largest tensile force was observed around alveolar bone of teeth, while compression force was observed at zygomatic buttress.

Stress analysis according to the different angulation of the implant fixture (임플란트 고정체의 매식 경사에 따른 응력분석)

  • Lee, Tae-Yup;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.321-329
    • /
    • 2002
  • Bending moments results from offset overloading of dental implant, which may cause stress concentrations to exceed the physiological capacity of cortical bone and lead to various kinds of mechanical failures. The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different angulated placement of dental implant in mandibular posterior missing areas. The three kinds of finite element model, were designed according to 3 main configurations: Model 1(parallel typed placement of 2 fixtures), Model 2(15. distal angulated placement of one fixture on second molar area), Model 3(15. mesial angulated placement of one fixture on second molar area). The cemented crowns for mandibular first and second molars were made on the two fixtures (4mm 11.5). Three-dimensional finite element models by two fixtures were constructed with the components of the implant and surrounding bone. A 200N vertical static load were applied to the center of central fossa and the point 2mm apart from the center of central fossa on each model. The preprocessing, solving and postprocessing procedures were done by using FEM analysis software NISA/DISPLAY IV Version 10.0((Engineering Mechanics Research Corporation, USA). Von Mises stresses were evaluated and compared in the supporting bone, fixtures, and abutment. The results were as following : (1) Under the point loading at the central fossa, the direction of angulated fixture affected the stress pattern of implants. (2) Under the offset loading, the position of loading affected more on the stress concentration of implants compare to the angulated direction of implants. The results had a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the placement angulation of implant fixture is placed toward mesial or distal direction. In designing of the occlusal scheme for angulated placement, placing the occlusal contacts axially during chewing appears to have advantages in a biomechanical viewpoint.

Stress analysis according to the vertical bone level in the implant placement (임플란트 매식 시 수직골 높이에 따른 응력분석)

  • Kim, Min-Ho;Park, Young-Rok;Kay, Kee-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.

A Literature Review on Locator Attachment for Implant Overdenture (임플란트 피개의치를 위한 Locator 어태치먼트: 문헌 고찰)

  • Cha, Min-Sang;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.127-140
    • /
    • 2013
  • The Locator attachment is used widely for implant retained overdenture. It can be used solitary and needs small vertical space. Locator can be applicable for parallel implants and divergent implants. Nylon male cap allow personalized retention for each case. In this literature review, initial retention force and changes in retention force of various attachments were evaluated. Rotation freedom and stress distribution around the attachment were reviewed. Moreover, patient satisfaction and maintenance care of Locator attachment were described. From all of the researches, it was drawn that Locator attachment can be used successfully and widely in several clinical situations.

Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary First Premolar (상악 제1소구치에서 전부도재관의 finish line 형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Lee, Sang-Kwon;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.219-237
    • /
    • 2003
  • he purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown, and 0.5mm width chamfer finish lines on the maxillary first premolar. 30 sound maxillary first premolars were selected and then storaged in 5% NaOCl and saline. 15 teeth were performed preparation for each group(1.0mm rounded shoulder, 0.5mm chamfer). After 30 stone dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the natural teeth. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co., Germany)was used to measure the fracture strength, with stress loading on the occlusal surface between buccal and lingual cusp. And also, three-dimensional finite element model was used to measure the stress distribution with two types of the finish lines(1.0mm rounded shoulder, 0.5mm chamfer) and two loading conditions(both buccal and lingual cusp inclination, lingual cusp inclination only). The result of the this study were as follows. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(842N) showed higher value than that of the chamfer(590N) (p<0.05). In the three dimensional finite element analysis of all ceramic crown, metal die and natural teeth model did not show any differences in stress distribution between finish lines. Generally, when force was loaded on the occlusal inclination of buccal and lingual cusp, the stress was concentrated on the loading point and the central groove of occlusal surface. When force was loaded only on the occlusal inclination of lingual cusp, the stress was concentrated on the lingual finish line and loading point.