• Title/Summary/Keyword: 음향파워 측정

Search Result 69, Processing Time 0.026 seconds

Calculation of the ultrasonic radiation force acting on a rigid circular cone and the study on the metrology for the acoustic power measurement (강체원뿔표적에 대한 초음파 방사힘 계산과 음향파워측정모델에 관한 연구)

  • Kyungmin Baik;Jooho Lee;Elmina B. C. Fritzie;Yong Tae Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.335-343
    • /
    • 2024
  • This paper came up with the theoretical modelling of the metrology for the acoustic power using ultrasonic radiation force and showed some theoretical results. In order to do this, a scattering model for a rigid circular cone based upon the Kirchhoff approximation was made, which was followed by the calculation of acoustic power, and then, was converted to the radiation force. From these works, it provided the accuracy and limitation of the conventional method using a circular cone, and the expanded metrology modelling that can be applied to a circular cone with arbitrary apex angle. Using these, this study provided the dependence of the metrology for the acoustic power using ultrasonic radiation force on the frequency and the size of the target. As a result, the correction was yielded in the value of the acoustic power calculated by the suggested International Electrotechnical Commission (IEC) method, which needs to be added when the frequency and the size of the target was considered.

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Sound Intensity Measurement in Near Field of Thin Plate Using Strain Gauge Bridge (스트레인 게이지 브리지를 이용한 얇은 평판의 근접장 음향 인텐시티 측정 방법론)

  • 김용조;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.71-76
    • /
    • 1996
  • 스트레인 게이지 브리지와 한개의 진동변위 탐촉자를 이용하여 평판의 근접장에서 음향 인텐시티를 측정하는 방법에 대하여 설명하였다. 또한 구조감쇠의 모델링을 통하여 음향방사파워에 대한 내부손실파워의 비를 나타내는 계수를 정의하여 내부손실파워의 정도를 평가하는 척도로 사용할 수 있음을 설명하였다. 임의의 경계조건을 가지는 평판에서 2개의 마이크로폰과 1개의 가속계를 이용하여 근사적으로 측정된 음향 인텐시티와 본고에서 제시한 방법으로 측정한 음향 인텐시티가 거의 일치함을 보이므로써 제시된 측정방법의 타당성을 검증하였다. 실험에 사용된 계(system)는 일반적인 해석에서 유체부하를 무시할 수 있는 계로 평판내부의 에너지 흐름에 비하여 외부로 방사되는 소음의 에너지 흐름이 매우 작기 때문에 평판내부의 에너지 흐름으로부터 방사되는 소음의 에너지 흐름을 알아내는 것이 매우 어려울 것으로 예상되었으나 본고에 제시된 방법으로 좋은 결과를 얻을 수 있었다. 앞으로 본 방법의 측정 오차에 대한 면밀한 고찰이 있어야 할 것이다. 그리고 평판의 내부손실이 비교적 큰 경우에 본 방법의 실험적으로 검증이 필요할 것이다. 또한 실질적인 문제에 응용되어 얼마만큼 유용한 정보를 제공할 것인가를 살펴보아야 할 것이다.

  • PDF

A Study to Estimate the Emitted Sound Power from the Rolling Stock (철도차량에서 방사되는 음향파워 추정에 관한 연구)

  • Lee, Young-Yeob;Kim, Jae-Chul;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.3
    • /
    • pp.211-215
    • /
    • 2011
  • Generally, sound power is one of the most significant factors to predict and assess noise from sound sources. However, many researchers developed indirect methods to calculate the sound power with noise level because it is impossible to measure sound power directly while a train is running. In this paper, we propose a method to estimate sound power generated due to wheel/rail interaction and propulsive equipment from the measurement of noise emitted from rolling stocks and verify the estimation method by comparing with the other sound power estimation formula. We also analyze the sound power of rolling stocks which are operating in domestic lines such as EMU, Mukoonghwa, KTX using the method proposed in this paper.

Measurement of Acoustic Power Radiating from Each Channel of Linear Array Transducer for Diagnostic Ultrasonic Imaging System (초음파 영상 진단기용 선형 어레이 변환기의 채널별 음향파워 측정)

  • Yun Yong Hyeon;Jho Moon Jae;Kim Yong Tae;Lee Myoung Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.351-352
    • /
    • 2004
  • 본 논문에서는 초음파 영상 진단기용 선형어레이 변환기를 장착할 수 있는 수조 와 128 채널의 스위칭 회로를 제작하여 변환기의 각 채널별 음향파워를 측정하였다. 실험은 128 채널 중 하나의 채널이 불량인 어레이 프로브를 대상으로 수행되었다. 측정 결과, 불량 채널의 음향 파워가 다른 채널에 비해 현저히 작게 나타남을 확인하였다.

  • PDF

Radiation Conductance Determination of Ultrasonic Transducer using the Laser Interferometry (레이저 간섭계를 이용한 초음파 변환기의 방사 컨덕턴스 결정)

  • 조문재
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.174-178
    • /
    • 1993
  • 초음파 변환기의 방사 컨덕턴스를 결정하기 위해서는 변환기로부터 방사된 음향파워와 입력전압의 정밀측정을 요구하게 된다. 음\ulcorner파워는 초음파를 거의 완전 반사시킬 수 있는 표적을 사용하여 변환기로부터 방사된 음압에 의해 표적에 가해진 힘을 수동맞저울과 레이저 간섭계로 측정하여 구하였으며, 입력전압을 열 변환기와 전압계를 한 시스템으로 하여 정밀 측정하였다. 방사 컨덕턴스의 최대 측정오차는 $\pm$4% 이내로 평가되었다.

  • PDF

Numerical comparative study on high-fidelity prediction of aerodynamic noise from centrifugal fan system (원심팬 시스템의 공력소음 고신뢰 예측을 위한 수치 비교 연구)

  • Seo-Yoon, Ryu;Minseung, Jung;Younguk, Song;Cheolung, Cheong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.713-722
    • /
    • 2022
  • In this paper, the flow performance and aero-acoustic noise generated by the target centrifugal fan system were investigated numerically and experimentally. Also, the numerical method for Computational Aero-Acoustics were evaluated by comparing each method. To analyze the performance of the centrifugal fan experimentally, the acoustic power level was measured in the semi-anechoic chamber using microphones, and the active frequency range for the noise performance was identified and that frequency range was applied for Computational Aero-Acoustics (CAA) techniques as sampling frequency. Then, Navier-Stokes equation and the Ffowcs Williams&Hawking equations were used to analyze the flow and sound power numerically, respectively, and a virtual acoustic radiation plane was designed and used for the implementation of the sound field. The accuracy and numerical characteristics of the numerical methods were validated by comparing simulated acoustic power levels with acoustic power levels measured.

Comparison Between Radiation Power and Beamforming Power of plate (평판에서의 음향 방사파워와 구면파 모델을 이용한 빔형성 파워와의 비교)

  • Kim, Young-Key;Kim, Yang-Hann
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.12-18
    • /
    • 1997
  • Beamforming method has a limited spatial resolution because of finite aperture size, so that the estimated source distributions are smoothed within the resolution. Especially for low frequency noise such as mechanical noise, this limitation often diminishes the direct use of beamforming method. In this study, the relation between smoothed beamforming and radiation power distribution of plate has been addressed. By adjustment of aperture size of array, the smoothed beamforming power shows radiation power distribution of plate. Numerical simulations are carried for simply supported plate.

  • PDF

Prediction Method of Control Valve Noise (잔향실을 이용한 콘트롤 밸브 소음 예측 방법)

  • 이용봉;윤병로;박경암;이두희;유선학
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.703-707
    • /
    • 2002
  • This paper proposes new method for predicting sound power emitted from the control valve and piping system. The sound power level measurement method using the reverberation chamber is much easy to apply in the field compared to the method using the anechoic chamber. Measured sound power was used to determine the coefficients of the equation predicting sound power level. The noise prediction equation was developed at relative flow coefficient, 0.11. The sound power level predicted is in good agreement with the measured value. Proposed method can be used to express the noise characteristics of the control valves.