• Title/Summary/Keyword: 음향파워크기

Search Result 15, Processing Time 0.022 seconds

Calculation of the ultrasonic radiation force acting on a rigid circular cone and the study on the metrology for the acoustic power measurement (강체원뿔표적에 대한 초음파 방사힘 계산과 음향파워측정모델에 관한 연구)

  • Kyungmin Baik;Jooho Lee;Elmina B. C. Fritzie;Yong Tae Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.335-343
    • /
    • 2024
  • This paper came up with the theoretical modelling of the metrology for the acoustic power using ultrasonic radiation force and showed some theoretical results. In order to do this, a scattering model for a rigid circular cone based upon the Kirchhoff approximation was made, which was followed by the calculation of acoustic power, and then, was converted to the radiation force. From these works, it provided the accuracy and limitation of the conventional method using a circular cone, and the expanded metrology modelling that can be applied to a circular cone with arbitrary apex angle. Using these, this study provided the dependence of the metrology for the acoustic power using ultrasonic radiation force on the frequency and the size of the target. As a result, the correction was yielded in the value of the acoustic power calculated by the suggested International Electrotechnical Commission (IEC) method, which needs to be added when the frequency and the size of the target was considered.

Precision Measurement of Ultrasonic Power the Milliwatt Range (밀리와트 영역의 초음파 파워 정밀 측정)

  • Jho, Moon-Jae;Hwang, Cheol-Ho;Suh, Sang-Joon;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.25-33
    • /
    • 1990
  • An ultrasonic power measurement system in milliwatt range was constructed. The ultrasonic power can be determined by measuring the radiation pressure on a target using self-compensating microbalance. Measurement was performed using a perfect reflector and a perfect absorber. In order to check the feasibility of the system, the ultrasonic power for the two targets was measured. Also, the systematic measurement errors and the reproducibility were examined. The relative error between two targets is proved to be within 2%. Also when the ultrasonic power range is larger than 10mW, the standard deviation for repeated measurement becomes smaller than ${\pm}$2%.

  • PDF

Application of Bispectral Analysis to Estimate Nonlinear Acoustic Parameter (음향 비선형 파라미터의 추정을 위한 바이스펙트럼 해석법의 적용)

  • Kim, K.C.;Jhang, K.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.85-92
    • /
    • 1999
  • The fact that material degradation can be evaluated by measuring nonlinear acoustic effect has been proposed by previous studies. The most conventional method to measure nonlinear acoustic effect is to measure the absolute magnitude of fundamental and $2^{nd}$ order harmonic frequency component in the propagated ultrasonic wave. For this aim, power spectral analysis technique has been used widely. However, the power spectral analysis has fatal disadvantage that the gaussian additive noise superimposed in the wave signal remains in the power spectrum domain. Moreover, the magnitude of $2^{nd}$ order harmonic frequency component generated by nonlinear effect is so small that it may be suppressed by the noise remained in the power spectrum. In order to overcome this problem, this paper proposes an alternative method using bispectrum analysis, which can reduce the effect of addictive gaussian noise and. the nonlinear parameter can be obtained more stably. Simulations showed that the proposed method can obtain the value of nonlinear parameter near to the true value in the case of low SNR signal. Also, in order to confirm the usefulness of our method in actual case, we compared the nonlinear parameter obtained by using both of power spectral and bispectral analysis for several specimen intentionally degraded by fatigue load.

  • PDF

The Analysis of the 3D underwater radiated noise pattern of cylinder structure using the underwater experiment (수중 실험을 통한 원통구조물의 3차원 수중 방사패턴 산출기법)

  • Yi, Jongju;Jung, Woojin;Kang, Myunghwan;Han, Seungjin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.407-408
    • /
    • 2014
  • 본 논문은 3차원 수중방사패턴 예측을 위하여 수중구조물의 표면진동장을 이용하여 3 차원 원음장 패턴을 예측한 뒤 수중구조물의 근접음장 계측데이터를 활용하여 산출된 원음장 음향파워를 이용하여 산출된 원음장 패턴의 음압크기를 보정하였고 이를 실험데이터와 비교 분석한 논문이다.

  • PDF

Noise Propagation Characteristics for Highspeed Train in Outdoors (고속철도소음의 전파특성)

  • 김정태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.73-79
    • /
    • 1996
  • 우리나라와 같이 철도의 운행위치와 소음 피해를 받는 수음자 간의 거리가 인접되어 있는 경우, 소음의 전파특성은 과도형상을 나타내는 구간에 속하게 되어 전파중에 나타나는 지표면의 다양한 물리적, 현상과 경계면 등의 이피던스 값등이 많은 영향을 끼치게 된다. 본 연구에서는 철도소음의 소음원 자체에 대한 모델링 기법과, 자유공간을 전파할 때 나타나는 거리감쇠 효과 등을 고려한 음향학적인 연속선음원 및 유한 불연속 선음원 등에 대한 검토가 이루어졌고, 특히, 소음원의 크기에 비교하여 수음자의 위치에 따라 저감되는 음향전파특성을 설명하였다. 또한, 유한한 길이를 가지고 있는 철도차량의 소음원 모델을 이용하여 향후 국내에서 운행되리라 예상되는 고속철도의 음향파워를 산출하였다. 산출된 음향파워로부터 철도변의 소음분포를 도출하였으며 고속철도의 경우 운행시 소음피해가 어느 정도인지를 예상하였다.

  • PDF

Sound Power Evaluation of Various Domestic Railroad Vehicles (국내 철도 차량의 음향발생 특성에 대한 비교 연구)

  • Kim, Jeung-Tae;Cho, Sung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.1
    • /
    • pp.28-37
    • /
    • 1999
  • Many residential areas are situated near to railroad tracks so that a railroad noise has been one of the major environmental issues. In this paper two important aspects have been investigated in order to properly evaluate the railroad vehicle noise : sound power levels for different types and sound propagation characteristics of the railroad vehicles. For noise source characteristics of railroad vehicles, sound power values for various types of trains that are in active service have been measured. In this paper, domestic railroad vehicles are measured and compared with high speed train(TGV). Based on sound power information of railway vehicles, prediction on the sound pressure level and equivalent noise level near to railway areas have been evaluated.

  • PDF

Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21 (IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개)

  • LEE, Sinlyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.241-246
    • /
    • 2021
  • Modern loudspeaker systems are changing an active loudspeaker system that have multiple input channels and power amplifier. So, we cannot measure these active loudspeakers with IEC 60268-5 standard. This paper introduces an IEC 60268-21 standard that can measure an active loudspeaker having many analog and digital and wireless or wired inputs and having various control parameters.

Characteristics Variation Analysis by Shape of Piezoelectric Ultrasonic Transducer with Non-Uniform Thickness (두께 불균일 압전 초음파 트랜스듀서의 형태에 따른 특성변화 해석)

  • Kim, Dong-Hyun;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.271-278
    • /
    • 2008
  • The electro-mechanical characteristics were theoretically analyzed for the wideband ultrasonic transducer made of non-uniform thickness piezoelectric vibrator. This paper proposes a combination of exponential functions which describes the thickness variation along the length of the vibrator to derive the input admittance and power transfer function of the transducer. The bandwidth and the power transfer function of the transducer were investigated while the lateral shape of the vibrator changes. The results showed there is an optimum shape for the wideband characteristics of the transducer, and the bandwidth has increased up to over 100% as the ratio of minimum value of thickness to maximum value decreases. However, the power transfer function had a downward trend as the ratio of thickness decreases. Also we confirmed that even though the value of transfer function increases as the length of the piezoelectric vibrator increases, the shape providing wideband characteristics is very limited. It means that precision processing is required to manufacturing a wideband ultrasonic transducer with high efficiency.

Magnitudes of the Harmonic Components Emitted from Utrasonic Contrast Agents in Response to a Diagnostic Utrasound: Theoretical Consideration (진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기: 이론적 고찰)

  • Kang Gwan Suk;Yu Ji Chul;Paeng Dong Guk;Rhim Sung Min;Choi Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.78-86
    • /
    • 2005
  • This study considers the magnitude of the harmonic components radiated from the ultrasonic contrast agents (UCA) activated by a typical diagnostic ultrasound. The nonlinear dynamic response of UCA to a 2 MHz diagnostic ultrasound pulse was predicted using Gilmore Model. The elastic property of the shell membrane of the UCA was ignored in the numerical model. Simulation was carried out for the UCA varying from 1 - 9 $\mu$m in its initial radius and the driving diagnostic ultrasound whose mechanical index (MI) ranges from 0.125 to 8. The powers of the sub. ultra and second harmonics of the acoustic signal from the UCA activated were compared with that of the fundamental component. The results show that. if the UCA is bigger than its resonant size (2 $\mu$m in radius for the present case) the sub harmonic power was much bigger than the fundamental. In particular, the 2nd harmonic component currently used as an imaging parameter for the harmonic imaging, was predicted to be lower in power than both the sub and the ultra harmonic component. This study indicates that, for obtaining harmonic imaging with UCA, the sub or ultra harmonics could be taken as imaging parameters better than the 2nd harmonic component.

Vibration of Pipes Coupled with Internal and External Fluids (내부 및 외부 유체와 연성된 파이프의 진동 해석)

  • Ryue, Jung-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.142-150
    • /
    • 2012
  • The waveguide finite element (WFE) method is a useful numerical technique to investigate wave propagation along waveguide structures which have uniform cross-sections along the length direction ('x' direction). In the present paper, the vibration and radiated noise of the submerged pipe with fluid is investigated numerically by coupling waveguide finite elements and wavenumber boundary elements. The pipe and internal fluid are modelled with waveguide finite elements and the external fluid with wavenumber boundary elements which are fully coupled. In order to examine this model, the point mobility, dispersion curves and radiated power are calculated and compared for several different coupling conditions between the pipe and internal/external fluids.