• Title/Summary/Keyword: 음이온교환

Search Result 360, Processing Time 0.027 seconds

Adsorption characterisctics of mixed resins for perchlorate ion (혼합수지를 이용한 과염소산 이온의 흡착 특성)

  • Park, Su-Min;Jeon, Byong-Hun;Jeong, Hyuk;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.429-436
    • /
    • 2010
  • The present research evaluates the efficiency of mixed resins between anion exchange resin and active carbon. We expected synergic effect from advantages of both adsorbents. Especially, this research focused on the removal of high cencentrated perchlorate ion from demilitarization solution. The total amount of the adsorbed perchlorate ion is increased considerably with mixed resins between mono functional anion exchange resin and granular active carbon from a single adsorbent. Results demonstated that this process not only improve the efficiency of adsorbing perchlorate, but save the time, space and cost for treating perchlotrate waste solution, because of reducing organic contaminant removing process. The interference effects from coexisting anions are not significant and can successfully applied to real demilitarization sample.

Preparation and Properties of Aminated Poly(ethersulfone) Ion-Exchange Membrane by UV Irradiation Method (UV 조사에 의한 아민화 Poly(ethersulfone) 이온교환막의 제조 및 특성)

  • Choi, Kuk-Jong;Hwan, Eui-Hwan;Rhee, Young-Woo;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.70-76
    • /
    • 2008
  • The PES-g-BTCA membrane was synthesized by UV irradiation method and then used to be modified into the PES anion exchange membrane by the amination reaction. Their chemical structures and adsorption properties were investigated. The degree of grafting and amination were increased with increasing the reaction time and had the maximum values of 138% and 1.20 mmol/g at 80 min, respectively. The initial thermal degradation temperature of PES membrane was $400^{\circ}C$. Which was reduced as the surface modification reaction had proceeded. The values of contact angle for PES membrane were decreased from 68.1 to $40.2^{\circ}$ with increasing the extent of amination, the water up-take and ion exchange capacity were also increased with increasing UV irradiation time until 80 min. The average pore size and BET surface area were decreased in order of PES, PES-g-BTCA, and aminated PES ion exchange membrane. Their average pore sizes were 624.8, 359.7, and 138.5 ${\AA}$, and their surface areas were 10.1,9.7 and 1.7 $m^2/g$, respectively.

Electrochemical Method for Measurement of Hydroxide Ion Conductivity and CO2 Poisoning Behavior of Anion Exchange Membrane (음이온 교환막의 정확한 OH-전도도 및 CO2 피독 효과 분석을 위한 전기화학적 측정법)

  • Kim, Suyeon;Kwon, Hugeun;Lee, Hyejin;Jung, Namgee;Bae, Byungchan;Shin, Dongwon
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2022
  • The anion exchange membrane used in alkaline membrane fuel cells transports hydroxide ions, and ion conductivity affects fuel cell performance. Thus, the measurement of absolute hydroxide ion conductivity is essential. However, it is challenging to accurately measure hydroxide ion conductivity since hydroxide ions are easily poisoned in the form of bicarbonate by carbon dioxide in the atmosphere. In this study, we applied electrochemical ion exchange treatment to measure the absolute hydroxide ion conductivity of the anion exchange membrane. In addition, we investigated the effect of carbon dioxide poisoning of hydroxide ions on electrochemical performance by measuring bicarbonate conductivity. Commercial anion exchange membranes (FAA-3-50 and Orion TM1) and polyphenylene-based block copolymer (QPP-6F) were used.

Synthesis of Amin-type Anion Exchanger from Acrylic Acid Grafted Polypropylene Nonwoven Fabric and Its Ion-exchange Property(II) (아크릴산 그라프트 폴리프로필렌 부직포로부터 아민형 음이온 교환체의 합성 및 이온교환특성(II))

  • Na, Choon-Ki;Park, Hyun-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.775-782
    • /
    • 2009
  • PP-g-AA-Am nonwoven fabric, which possess anionic exchangeable function, was prepared by chemical modification of carboxyl (-COOH) group of PP-g-AA nonwoven fabric to amine ($-NH_2$) group using diethylene triamine (DETA). Its adsorption characteristics for anionic nutrients including isotherm, kinetics and co-anions were studied by batch adsorption experiments. Adsorption equilibriums of $PO_4$-P on PP-g-AA-Am fabric were well described by the Langmuir isotherm model, and their adsorption energies were ranged 10.3 kJ/mol indicating an ion-exchange process as primary adsorption mechanism. The adsorption selectivity of PP-g-AA-Am nonwoven fabric for anions under competition with each other was in following order: $SO_4\;^{2-}$>$PO_4\;^{3-}$>$NO_3\;^-$>$NO_2\;^-$. Also, all results obtained from this study indicate that the $PO_4$-P removal capacity of PP-g-AA-Am nonwoven fabric was extremely superior to that of PA308 anion-exchange resin.

유가금속 회수공정 폐액중 셀레늄 제거에 관한 연구

  • Han, Sang-Uk;Lee, Hak-Seong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.495-498
    • /
    • 2008
  • 여러 가지 흡착제를 사용한 회분식 흡착성능 측정 실험에서 흡착성능은 음이온교환수지 > 입상활성탄 > Biomass > 분말활성탄 > 제올라이트 순으로 나타났으며, 모든 흡착제는 30분 안에 흡착평형 상태에 도달 하였다. 음이온교환수지를 이용한 회분식 흡착실험에서 최대흡착량은 pH 10에서 0.0483 mmol/g로 가장 높았고, 대체적으로 pH가 높은 범위에서 흡착이 잘 되는 것으로 밝혀졌다. 이것은 산화물 상태의 셀레늄이 pH 6 이하의 영역에서는 HSeO$_3^{-}$가 존재하며, PH 6$\sim$10 영역에서는 HSeO$_3^{-}$와 SeO$_3^{-2}$가 공존하며, pH 10 이상에서는 SeO$_3^{-2}$만 존재함을 알 수 있는데, 실험에서도 유사한 결과가 나온 것으로 사료된다. 입상활성탄을 이용한 흡착실험에서 최대흡착량은 pH 4.5에서 0.0574 mmol/g으로 가장 높았다. pH 4.5$\sim$6.5 범위에서는 대체적으로 비슷한 성능을 나타내었다. 입상활성탄의 표면전위 특성상 음이온으로 존재하는 셀레늄과 정전기적 반발력으로 인해 흡착이 거의 일어나지 않는 것으로 보이지만, 음이온 상태로 존재하는 셀레늄 이외의 금속간 화합물이나 물리적인 결합상태의 미세입자들이 흡착된 것으로 보인다.

  • PDF

Effect of Silicotungstic Acid as Inorganic Filler on the Properties of Anion Exchange Composite Membranes (무기첨가제 규소텅스텐산이 음이온교환 복합막 특성에 미치는 영향)

  • LEE, KYU HA;YOO, DONG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.28-37
    • /
    • 2022
  • In this study, we synthesized a poly(pheneylene oxide) (PPO)-based organic/inorganic composite membrane having silicotungstic acid (STA) for the development of an anion exchange membrane with excellent ionic conductivity and physicochemical stability. The organic/inorganic composite membranes were prepared by introducing different STA contents (0 wt%, 10 wt%, 30 wt%, and 50 wt%) into the quaternizaed(Q)-PPO matrix. The prepared anion exchange membranes were subjected to structural analysis by proton neclear magnetic resonance and Fourier transform infrared, and thermal behavior of membranes was confirmed by thermogravimetric analysis. Among the prepared composite membranes, the ion conductivity of Q-PPO/STA-50 (40.5 mS cm-1) showed 1.46 times compared to that of the pristine membrane (27.6 mS cm-1). Therefore, these results demonstrated that organic/inorganic composite membranes are promising candidates for application of anion exchange membranes.

Sequencing Chemical Equilibrium Modeling for Ion Exchange in ETA and ${NH}_{3}$ Aqueous Solutions (ETA 및 암모니아 수용액에서 연속화학평형 모델을 이용한 이온교환 모델링)

  • 이인형;안현경;김상대
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.325-327
    • /
    • 2003
  • 원자력 발전소 2차계통수에는 pH를 조절하여 부식을 억제하기 위해 pH제어제로 암모니아를 사용하였으나 상변화 지역에서 액상의 pH가 낮아 부식생성물이 생성, 증기발생기로 유입되어 진열관의 부식을 촉진 시킨다. pH 제어제로 암모니아 대신 ETA를 도입하여 pH를 증가시키고 증기발생기로 유입되는 부식생성물의 양을 감소하여 진열관의 부식을 억제시키고 있다. 그러나 암모니아에서 ETA로 변경함에 따라 증기 발생기취출수계통의 탈염의 운진기간이 단축되었다. 따라서 본 연구의 목적은 탈염기의 수지 교체주기도 연장시키고 안전성도 확보할 수 있는 탈염기내 양ㆍ음이온 이온교환수지 조성 비율을 최적화하는데 있다. 연속화학평형모델을 이용한 결과 양ㆍ음이온 이온교환수지 비율이 10:1일 경우 최적인 것으로 조사되었다.

  • PDF

Controlling Water Splitting Characteristics of Anion-Exchange Membranes by Coating Imidazolium Polymer (이미다졸륨 고분자 코팅을 통한 음이온교환막의 물분해 특성 제어)

  • Kim, Do-Hyeong;Park, Jin-Soo;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.152-161
    • /
    • 2015
  • In this study, novel pore-filled anion-exchange membranes (PFAEMs) with low electrical resistance, high permselectivity, and low water-splitting flux property under a concentration polarization condition have been developed for the enhancement in the efficiency of electrochemical water treatment processes. The base membranes have been prepared by filling a copolymer containing quaternary ammonium groups with an excellent ion-exchange capability into a porous polyolefin substrate, showing a high performance superior to that of a commercial membrane. In addition, it was confirmed that the electrochemical membrane performances are preserved while the water-splitting flux is effectively controlled by coating an imidazolium polymer onto the surface of the base membrane. The prepared PFAEMs revealed remarkably low electrical resistances of about 1/6~1/8 compared to those of a commercial membrane, and simultaneously low water-splitting flux comparable with that of cation-exchange membranes under a concentration polarization condition.

Separation of Vanadium and Tungsten from Simulated Leach Solutions using Anion Exchange Resins (음이온교환 수지를 이용한 바나듐/텅스텐 혼합용액으로부터 바나듐/텅스텐 분리회수에 관한 연구)

  • Jong Hyuk Jeon;Hong In Kim;Jin Young Lee;Rajesh Kumar Jyothi
    • Resources Recycling
    • /
    • v.31 no.6
    • /
    • pp.25-35
    • /
    • 2022
  • The adsorption/desorption behavior and separation conditions of vanadium and tungsten ions were investigated using a gel-type anion-exchange resin. In the adsorption experiment with the initial acidity of the solution, the adsorption rate of vanadium was remarkably low in strong acids and bases. Additionally, the adsorption rate of tungsten was low in a strong base. An increase in the reaction temperature increased the adsorption reaction rate and maximum adsorption. The effect of tungsten on the maximum adsorption was minimal. The adsorption isotherms of vanadium and tungsten on the ion-exchange resin were suitable for the Langmuir adsorption isotherms of both the ions. For tungsten, the adsorption isotherms of vanadium and tungsten were polyoxometalate. Both ion-exchange resins were simulated using similar quadratic reaction rate models. Vanadium was desorbed in the aqueous solutions of HCl or NaOH, the desorption characteristics of vanadium and tungsten depended on the desorption solution, and tungsten was desorbed in the aqueous solution of NaOH. It was possible to separate the two ions using the desorption process. The desorption reaction reached equilibrium within 30 min, and more than 90% recovery was possible.

Ion Exchange of Gold(III) from Ammonium Chloride Solution by Anionic Resins (염화암모늄용액에서 음이온 교환수지에 의한 금(III)의 이온교환)

  • Ahn, Hyeong Hun;Lee, Man Seung
    • Resources Recycling
    • /
    • v.27 no.2
    • /
    • pp.48-54
    • /
    • 2018
  • Batch ion exchange experiments of Au(III) were performed from ammonium chloride solution by employing strong anionic exchange resins (Amberlite IRA 402 and AG 1-X8). Au(III) was well loaded into the two resins and the loading behavior of Au(III) into AG 1-X8 was superior to that into Amberlite IRA 402. The loading of Au(III) into AG 1-X8 followed Langmuir adsorption isotherm and the experimentally determined loading capacity was 355 mg/g. Au(III) was successfully eluted by $HClO_4$ from the loaded AG 1-X8 and the elution percentage of Au(III) increased with the concentration of $HClO_4$.