• Title/Summary/Keyword: 음압 분포

Search Result 82, Processing Time 0.022 seconds

Study on the Measurements of Architectural Acoustie by Cross-Correlation Methods (상호상관법에 의한 건축음향측정에 관한 연구)

  • Park, Byoung-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.42-52
    • /
    • 1990
  • A method of measuring impulse response of acoustic system, two kinds of cross-correlation methods (the direct correlation method and the M-sequence modulation correlation method) were applied. According to the direct correlation method, by using stationary random noise source and by calculating the cross-correlation function between the sourece and the output signal, equivalent impulse response can be obtained not being influenced by the back ground noises. By applying this method, the measurement of echo-time patterns in rooms and oblique incident sound absorption characteristics of sound absorbing materials was carried out. In the case of the M-sequence modulation correlation method which was contrived by Aoshima, an intermittent random nosie modulated by M-sequence signal is used as the source signal, and the cross-correlation function between the M-sequence signal and the squared output signal is calculated. According to this method, equivalent energy impulse response (squared impulse response) of te propagation system can be obtained without being influenced by the back ground noises and the air fluctuation caused by wind. As the applcaition of this measuring method to the architectural acoustics, the meaurements of echo-time patterns, reverberation decays and sound pressure lev디 distributions in rooms and sound insulation efficiencies in buildings were carried out. From these experimental studies, it has been found that this M-sequence modulation correlation method is markedly useful especially for the field masurement of sound insulation under high back ground noise condition.

  • PDF

Prediction of Strength and Propagation Characteristics of Supersonic Flight Sonic Boom (초음속 비행체의 소닉붐 강도와 전파 특성 예측)

  • Jung, Suk Young;Ha, Jae-hyoun;Lee, Younghwan;Jin, Hyeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.497-504
    • /
    • 2020
  • A technique was developed for analysis on sonic boom created by supersonic flight and for prediction of its sound level and atmospheric propagation characteristics. It is of great importance to anticipate sound level of sonic boom because it causes environmental issue. For that purpose, the simplified sonic-boom prediction method was applied to calculate sound pressure according to physical properties and flight information of the object and distance to measurement site, in this study. Propagation characteristics of shock wave emanated from a flying object was analyzed by using line-of-sight vector and ray tracing method which dealt with refraction of wave due to atmospheric density distribution along altitude. Predicted results agreed well with measured data from real flight.

Sound Source Localization Method Based on Deep Neural Network (깊은 신경망 기반 음원 추적 기법)

  • Park, Hee-Mun;Jung, Jong-Dae
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1360-1365
    • /
    • 2019
  • In this paper, we describe a sound source localization(SSL) system which can be applied to mobile robot and automatic control systems. Usually the SSL method finds the Interaural Time Difference, the Interaural Level Difference, and uses the geometrical principle of microphone array. But here we proposed another approach based on the deep neural network to obtain the horizontal directional angle(azimuth) of the sound source. We pick up the sound source signals from the two microphones attached symmetrically on both sides of the robot to imitate the human ears. Here, we use difference of spectral distributions of sounds obtained from two microphones to train the network. We train the network with the data obtained at the multiples of 10 degrees and test with several data obtained at the random degrees. The result shows quite promising validity of our approach.

Numerical Investigation of Sunroof Buffeting for Hyundai Simplified Model (HSM의 썬루프 버페팅 수치해석)

  • Khondge, Ashok;Lee, Myunghoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.180-188
    • /
    • 2014
  • Hyundai Motor Group(HMG) carried out experimental investigation of sunroof buffeting phenomena on a simplified car model called Hyundai simplified model(HSM). HMG invited participation from commercial CFD vendors to perform numerical investigation of sunroof buffeting for HSM model with a goal to determine whether CFD can predict sunroof buffeting behavior to sufficient accuracy. ANSYS Korea participated in this investigation and performed numerical simulations of sunroof buffeting for HSM using ANSYS fluent, the general purpose CFD code. First, a flow field validation is performed using closed sunroof HSM model for 60 km/h wind speed. The velocity profiles at three locations on the top surface of HSM model are predicted and compared with experimental measurement. Then, numerical simulations for buffeting are performed over range of wind speeds, using advanced scale resolving turbulence model in the form of detached eddy simulation (DES). Buffeting frequency and buffeting level are predicted in simulation and compared with experimental measurement. With reference to comparison between experimental measurements with CFD predictions of buffeting frequency and level, conclusion are drawn about predictive capabilities of CFD for real vehicle development.

Numerical Simulation of Directivity for Probe and Surface Defect (탐촉자와 표면 결함에 대한 지향성의 수치 실험에 관한 연구)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.291-298
    • /
    • 1995
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. This paper studied the directivity of shear waves emitted from angle probes and scattered from surface defects by using visualization method. These experimental results were compared with the theory which was based on the continuous wave. The applicability of continuous wave theory was discussed in terms of the parameter $d/{\lambda}$; where d is transducer or defect size and ${\lambda}$ is the wavelength. In the case of angle probes, the experimental results show good agreement with theoretical directivity on the principal lobe. When defect size was smaller than the wavelengths, clear directivity in the reflected wave was observed. In the case of the same ratio of defect size to wavelength, the directivity of reflected waves from the defect show almost the same directivity in spite of frequency differences. When the $d/{\lambda}$ is greater than 1.5, measured directivities almost agreed with the theoretical one.

  • PDF

A Study on the Propagation Characteristics of Fire Alarm Sound in Buildings (화재비상경보음의 건물 내 전달특성에 관한 연구)

  • Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.153-160
    • /
    • 2009
  • This study aims to review the propagation characteristics of fire alarm sound in building through computer simulation. In order to achieve this goal, the sound power level of existing three different emergency alarms were measured in an anechoic chamber. Sound power level of alarm bell was 98.6dB and electronic-siren speaker was 95.7dB, and electronic-siren phon was 101.8dB at the voltage of DC 24V in the condition of anechoic chamber. As the results of acoustic simulation, it was shown that sound levels at the corridor of the building were relatively high and even. But, there were large difference in sound level at all the frequency bands between corridor and lecture rooms. This mean that alarm sound couldn't be recognized sometimes in lecture rooms. Through the computer simulation, the propagation characteristics of fire alarm sound could be forecasted and compared due to plans of buildings.

Soundness evaluation of friction stir welded A2024 alloy by non-destructive test (비파괴검사에 의한 A2024 마찰교반용접부의 건전성 평가)

  • Ko, Young-Bong;Kim, Gi-Beom;Park, Kyeung-Chae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.135-143
    • /
    • 2013
  • Friction Stir Welding (FSW) was developed, it is successfully commercialized in the field of transportation vehicles. In this study, we analyzed the defects of A2024-T4 alloy using non-destructive test of radiograph, ultrasonic, electrical conductivity and destructive test of microstructure observation, tensile strength. As the results of experiment, mapping of defects was obtained. Fine defects which were not detected in radiograph test were detected in ultrasonic test, and it enabled efficient detection of defects by difference of sound pressure and color. The values of electrical conductivity was decreased as amount of defects was increasing. Joint efficient of defect-free weldment that found by non-destructive and destructive test was 91%. Therefore it was considered that non-destructive test of friction stir welded A2024-T4 Alloy was an efficient method.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Simulation for application of pumping-and-treatment system to the recovery of non-aqueous phase liquids (NAPLs) at and below the water table (토양의 포화지대에 분포하는 고밀도비수상액체(DNAPL)와 저밀도비수상액체(LNAPL)의 펌핑 제거공정에 대한 모사)

  • 김주형;이종협
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.51-61
    • /
    • 1997
  • The objective of this study is to evaluate the feasibility of Pumping-and-Treatment system (PTS) for remediation of the saturated zones contaminated with NAPLs. A simulation is carried out for the removal of DNAPLs (denser-than-water non-aqueous phase liquids) and LNAPLS (lighter-than-water non-aqueous phase liquids) distributing at and below the water table. In the study, LNAPL and DNAPL are assumed to be n-hexane and 1,1-dichloroacetone, respectively. The model system studied consists of four heterogeneous soil layers with different permeabilities. Groundwater flows through the bottom layer and a pumping well is located under the initial water table. The time-driven deformation of the water table and removal efficiency of contaminants are estimated after vacuum application to the inlet of the well. In the calculation, FVM (Finite Volumetric Method) with SIMPLEC algorithm is applied. Results show that removal efficiencies of both DNAPL and LNAPL are negligible for the first 5 days after the PTS operation. However, when the cone-shape water table is formed around the inlet of the pumping well, the rapid removal rate is obtained since NAPLs migrate rapidly through the curvature of the water table. The removal efficiency of DNAPL is estimated to be higher than that of LNAPL due to the gravity. The results also show that the fluctuation or cone-shaped depression of the water table enhances the removal efficiency of NAPLs in saturated zones. The simulation results could provide a basis of the PTS design for the removal of NAPLs in saturated zones.

  • PDF

Effect of Diffuser Locations on the Room Acoustical Parameters in 1:25 Scale Model Hall (1:25 축소모형 홀에서 확산체의 설치부위에 따른 실내 음향지표의 변화)

  • Kim, Yong-Hee;Seo, Choon-Ki;Lee, Hye-Mi;Jeon, Jin-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.115-128
    • /
    • 2012
  • This paper investigates the effects of diffuser on the acoustical parameters in music hall with consideration of the result of scattering coefficient measurement. A scale model hall of 600 seats with orchestra shell was used for experiments. The materials of 1:50 scale model was chosen through absorption coefficient measurement based on ISO 354. The model was matched to the computer simulation model in terms of reverberation time. In order to evaluate the effect of diffuser location, the measurements were accomplished with and without diffusers according to 7 configurations by diffuser-installed region; sidewall, balcony front, ceiling and so on. The following acoustical parameters were extracted from each measurement case; Reverberation time (RT), Early decay time (EDT), Clarity (C80), Center time (Ts), Sound strength (G) and Temporal diffusion (TD) from the auto-correlation function (ACF) of impulse responses. As a result, the absorption power and diffusion power were increased with number of diffusers. Accordingly RT, EDT and G were decreased by diffuser and the redirection of reflections was occurred briskly. Averaged TD was 6.05 to 6.30 by measurement cases. RT was found to be the most related factor to diffusion power (R = 0.94). The correlation between TD and EDT was high (R = 0.73). In addition, the effects of diffuser-installed location were discussed in terms of acoustical parameter variation.