• Title/Summary/Keyword: 유체 주입

Search Result 204, Processing Time 0.027 seconds

A Study on the Atomization Characteristics of Effervescent Atomizer with PDPA (PDPA를 이용한 기체주입미립화기의 미립화 특성에 관한 연구)

  • Kim, Hyung-Gon;Yano, Toshiaki;Song, Kyu-Keun;Jung, Byong-Koog;Jung, Jae-Youn;Cho, Tae-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1316-1321
    • /
    • 2004
  • An experimental study is performed on atomization characteristics and stable operating condition for injection of high viscous waste vegetable oil using effervescent atomizer with two aerator tubes. Consideration is given to the effects of ALR and liquid viscosity on the velocity and mean diameter of the injected droplet. It is found that (i) as ALR increases, the axial velocity of the droplet is increased, while half-velocity width and SMD are decreased regardless of the change in liquid viscosities, (ii) the rate of fine drop distribution occupied in the total spray field is increased with an increasing in ALR, and (iii) the effect of viscosity on atomization characteristics is minor.

  • PDF

Ethanol Concentration Sensor Using Microfluidic Metamaterial Absorber (에탄올의 농도를 검출하기 위한 미세유체 메타물질 흡수체)

  • Kim, Hyung Ki;Yoo, Minyeong;Lim, Sungjoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.506-513
    • /
    • 2015
  • In this paper, we proposed a novel ethanol concentration sensor using microfluidic metamaterial absorber. The metamaterial absorber comprises a split-ring-cross resonator(SRCR) and a microfluidic channel. The SRCR can generate LC resonance that is very sensitive to changes in the effective dielectric constant around the capacitive gap. In addition, microfluidic channels can change the effective dielectric constant of the dielectric substrate by using an infinitesimal quantity of a liquid on the order of microliters. The proposed absorber can detect the electrical properties of different concentration of ethanol. The performance of the proposed absorber is demonstrated using the absorption measurements of a fabricated prototype sample with waveguides. In addition, the simulated results and measurement results show good agreement.

Fabrication of a Micro Fluidic Device for Micro-FACS and Test of Electroosmosis (Micro-FACS용 미세 유첼 소자의 저작 및 전기삼투 구동 시험)

  • Choi, Eun-Soo;Kim, Geun-Young;Park, Tae-Gyu;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.69-71
    • /
    • 2001
  • 본 논문에서는 FACS(fluorescence activated cell sorting)의 초소형화를 위한 미세 유체소자들을 플라스틱 기판에 집적하여 제작하고 전기삼투를 이용해서 세포가 일렬로 이송되는 특성을 시험한다. 제작된 미세 유체 소자는 유리 하부 기판과 플라스틱 상부 기판 및 전원장치로 구성된다. 상부기판은 세포를 주입하기 위한 샘플 측 레저버와 세포를 운반 및 일렬 이송이 가능하게 하는 버퍼를 저장할 두 개의 레저버가 있고 이들이 배출되는 레저버로 구성된다. 마이크로머시닝 기술을 이용하여 실리콘 기판 위에 미세 채널 몰드를 제작한 후 PDMS(polydimethylsiloxane)로 주물을 제작한다. $O_2$ 플라즈마를 이용하여 유리 기판과 PDMS 주물을 접합하며 제작된 채널에 적색 잉크와 bead를 샘플 측에 충전하고 버퍼 측에 sodium borate를 충전한 후 전기삼투로 구동시킨다. bead가 일렬로 이송되도록 전장을 조절하고 이때의 유속과 유량을 측정한다. 다양한 전장에 따른 실험을 통하여 채널의 구조를 최적화한다.

  • PDF

A Study on the Flow Characteristics of Fluidic Valve (Fluidic Valve의 유동 특성에 관한 연구)

  • Yoo, Seong-Yeon;Jie, Myoung-Seok;Kim, Ki-Hyung;Kim, Man-Woong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.425-432
    • /
    • 2001
  • Fluidic valve is adopted in APR1400 to control passively the flow rate of cooling water from the safety injection tank. It is necessary to establish independent evaluation guideline for the flow characteristics of fluidic valve in order to secure safety. Three dimensional numerical model for fluidic valve is developed and numerical results are compared with experimental data obtained at KAERI in order to verify numerical simulation. Also influence of the grid number and the turbulence model were investigated. In addition, variation of flow rate is investigated at various elapsed times after valve operating, and flow characteristics are analyzed at low and high flow rate conditions, respectively.

  • PDF

Disposable Microfluidic Infusion Pump using Elastomeric Blister Actuator (탄성 블리스터 액츄에이터를 이용한 일회용 미세유체 주입펌프)

  • Jang, Woong Ki;Kim, Hyung Jin;Kim, Byeong Hee;Seo, Young Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.235-240
    • /
    • 2013
  • This paper presents a disposable microfluidic infusion pump using the restoring force of elastomeric membrane of Polydimethylsiloxane. Microfluidic infusion pump consists of hydraulic resistance control part, elastomeric blister actuator part, drug inlet and outlet. Expanded elastomeric blister actuator continuously pushes liquid in the chamber to outlet. At same time, microchannel diameter near the outlet was controlled by thin elastomeric membrane in hydraulic resistance control part. Eventually flow rate of infused liquid is controlled by air pressure. In experimental study, the amount of the filled liquid in the blister is precisely controlled by the height of the blister. Flow rate of infused liquid could be controlled, that is, controlled release of the drug over time was possible by adjusting hydraulic resistance and restoring pressure with the blister actuator.

Heat Transfer Characteristics of the U-shape Heat Pipe using Working Fluid of PFC (PFC 작동유체 사용 U형 히트파이프의 열전달특성 연구)

  • 이기우;박기호;전원표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.796-802
    • /
    • 2001
  • The purpose of the present study is to examine the heat transfer characteristics of the U-shape heat pipe for the cooling of semiconductor in subway train. Perflouro-carbon(PFC) was used as working fluid. Temperature distribution on the surface and heat transfer coefficients were investigated according to the working fluid volume percent and heating rate. The results were as follows; Optimum volumetric percent of working fluid was from 80% to 90%, and hat transfer coefficients of evaporation and condensation were as follows, respectively. $\hbar_ie=0.37\times(\frac{P_i}{P_O})$l_c}^0.3$,$\hbar_ic-4.2(\frac{\kappa_l^3p_l^2gh_fg}{\mu_lq_c_l_c}^\frac{1}{3}

  • PDF

Numerical Study on Operating Factors Affecting Performance of Surfactant-Enhanced Aquifer Remediation Process (계면활성제 증진 대수층 복원 프로세스에 영향을 미치는 운영 인자들에 대한 수치 연구)

  • Lee, Kun-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.7
    • /
    • pp.690-698
    • /
    • 2010
  • Contamination of groundwater resources by organic chemicals has become an issue of increasing environmental concern. Surfactant-enhanced aquifer remediation (SEAR) is widely recognized as one of the most promising techniques to remediate organic contaminations in-situ. Solutions of surfactant or surfactant with polymer are used to dramatically expedite the process, which in turn, may reduce the treatment time of a site compared to use of water alone. In the design of surfactant-based technologies for remediation of organic contaminated aquifers, it is very important to have a considerable analysis using extensive numerical simulations prior to full-scale implementation. This study investigated the formation and flow of microemulsions during SEAR of organic-contaminated aquifer using the finite difference model UTCHEM, a three-dimensional, multicomponent, multiphase, compositional model. The remediation process variables considered in this study were the sequence of injection fluids, the injection and extraction rate, the concentrations of polymer in surfactant slug and chase water, and the duration of surfactant injection. For each variable, temporal changes in injection and production wells and spatial distributions of relative saturations in the organic phase were compared. Cleanup time and cumulative organic recovery were also quantified. The study would provide useful information to design strategies for the remediation of nonaqueous phase liquid-contaminated aquifers.

Reservoir Modeling for Carbon Dioxide Sequestration and Enhanced Oil Recovery (이산화탄소 지중저장과 원유 회수증진 공정을 위한 저류층 모델링)

  • Kim, Seung-Hyok;Lee, Jong-Min;Yoon, En-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.35-41
    • /
    • 2012
  • Manifold researches for carbon capture and storage (CCS) have been developed and large scale-carbon capture system can be performed recently. Hence, the technologies for $CO_2$ sequestration or storage become necessary to handle the captured $CO_2$. Among them, enhanced oil recovery using $CO_2$ can be a solution since it guarantees both oil recovery and $CO_2$ sequestration. In this study, the miscible flow of oil and $CO_2$ in porous media is modeled to analyze the effect of enhanced oil recovery and $CO_2$ sequestration. Based on Darcy-Muskat law, the equation is modified to consider miscibility of oil and $CO_2$ and the change of viscosity. Finite volume method is used for numerical modeling. As results, the pressure and oil saturation changes with time can be predicted when oil, water, and $CO_2$ are injected, respectively, and $CO_2$ injection is more efficient than water injection for oil recovery.

자성유체 윤활제의 개발 동향

  • 김영규;심우전;김청균
    • Tribology and Lubricants
    • /
    • v.12 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • 자성유체는 자연에서 추출한 것이 아니라 자화성(Magnetizability)과 유도성(Flowability)을 동시에 갖도록 합성한 특수액체이다. 자성유체는 1960년대 중반에 미국의 NASA에서 처음 개발된 이후로 윤활, 밀봉, 감쇄, 의료 등의 분야에서 응용연구가 많이 진행되었기 때문에 고도의 정밀도를 요하는 항공, 우주산업, 컴퓨터와 반도체 분야 등에서 실용화가 크게 진전되고 있다. 특수물질일 자성유체는 전기적으로 도체인 10nm 정도의 미세한 자기입자(Magnetic particles)에 코팅을 한 후, 이것을 물, 탄화수소, 플루오르카본, 에스터 등의 매개유체(Carrier Fluids)에 혼합시켜서 콜로이드 상태로 사용하게 된다. 자성유체는 미세한 자기입자들이 매개유체내에서 서로 충돌하면서 반발력을 발생시켜서 상호간에 늘 콜로이드 상태를 유지하고 있으며, 이 특수유체가 자기장의 영향을 받게 되면 점도가 증가하면서 특이한 성질을 갖게 된다. 상대 접촉 운동면에 경계마찰이나 혼합마찰을 하게 되면 윤활상태는 비교적 나쁘다. 이러한 마찰지역에 콜로이드상의 자성유체 윤활제를 공급하면 기존의 윤활제에 비하여 대단히 효과적으로 윤활을 할 수 있게 된다. 그러나 자성유체 윤활제가 마찰부위에 원활하게 공급하기 위해서는 미끄럼 마찰부에서 자기장을 잘 형성시킬 수 있는 도체이어야 하기 때문에 특별한 윤활 시스템 설계가 제시되어야 한다. 자성유체 윤활제는 합성으로 제조된 특수물질로 여러가지 장점을 갖고는 있으나 기존 윤활유와의 적합성, 마찰열, 밀봉압력 등의 조건에서 제한적으로 사용될 수 밖에 없으므로 항공, 우주 산업이나 석유 화학분야와 같이 특수 환경에서만 사용되고, 또한 기존의 광유계 윤활제에 비하여 대단히 고가하는 문제점을 갖고 있다. 그러나 윤활 마찰면의 다양화와 가혹한 사용조건은 자성유체 윤활제의 연구개발 필요성을 크게 증대시키고 있다.xed Effects Model)을 결정하고, 각각에 해당하는 통계모형을 구축하였다. 이 결과 (1) 업종 및 기업규모별로 그룹간에 유의한 특성이 발견되었으며, (2) R&D 및 광고투자는 기업의 시장성과를 설명하는 중요한 변수이나, (3) R&D 투자의 경우는 광고에 비해 불확실성이 존재하는 것으로 나타났고, (4) 수리모형에서 도출된 한계원리가 통계모형에서도 유효한 것으로 드러났다.등을 토대로 한 10대 산업을 육성하기 위하여 과학기술부는 기술수요조사를 바탕으로 49개 주요기술을 도출하여, 과학기술 일류 국가 실현, 국민소득 2만불 달성이라는 국가적 슬로건을 내걸고 “차세대 성장동력” 창출을 위한 범정부차원의 기획과 연구비의 집중투자를 추진하고 있다.달성하기 위해서는 종합류류 전산망의 시급한 구축과 함께 화물차의 적재율을 높이고 공차율을 낮출 수 있는 운송체계의 수립이 필요한 것으로 판단된다. 그라나 이러한 화물전용차선의 효과는 단기적인 치유책일 수밖에 없기 때문에 물류유통 시설의 확충을 위한 사회간접자본의 구축을 서둘러 시행하여야 할 것이다.으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압주입시험에서도 확인된다.. It was resulted from increase of weight of single cocoon. "Manta"2.5ppm produced 22.2kg of cocoon. It is equal to 9% increase in index, as compared to that of control. In case

Design and Assessment of an Oil-treatment Process for Bitumen Separation (비투멘 유체 분리를 위한 오일처리공정의 설계와 평가)

  • Jeong, Moon;Lee, Sang-Jun;Shin, Heung-Sik;Jo, Eun-Bi;Hwang, In-Ju;Kang, Choon-Hyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.5-9
    • /
    • 2016
  • The purpose of this paper is to define criteria to be used as part of the engineering design for an oil sands plant equipped with the steam assisted gravity drainage process. In this effort, the oil treatment process of an oil sands plant on a pilot scale was focused for detailed investigation. The thermodynamic properties of the process fluid, which is mainly composed of bitumen and water, were estimated with the CPA model. The commercial tool aspen HYSYS was used for the analysis throughout this work along with the provided input data and some necessary assumptions. From the simulation results, the heat and mass balances for a 300 BPD plant were established in order to define standard data for its modular design. In particular, the basis of design for equipment size, heat transfer areas, capital cost and operation cost was extensively discussed.