• Title/Summary/Keyword: 유전율 측정

Search Result 471, Processing Time 0.029 seconds

Measurement of the planar substrate dielectric constant using a microstrip line (마이크로스트립 선로를 이용한 기판의 유전율 측정)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • This paper suggested the fast and easy method of the dielectric constant measurement for planar dielectrics using a microstrip line. The complex permittivity and permeability were presented by the first reflection and transmission coefficient which were derived from the scattering parameters. This method was verified by the measurement of a known planar dielectric using a microstrip line. This method can be applied to the dielectric constant measurement of unknown planar dielectric.

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1287-1288
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe를 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2253-2254
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe클 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.621-622
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe를 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1747-1748
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe를 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

유전율을 이용한 토양오염 모니터링 기법의 제안

  • 김만일;김형수;정교철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.104-107
    • /
    • 2004
  • 지반오염을 조사하기 위해서는 시추작업을 통하여 시료를 채취하는 방법이 일반적이지만, 실시간으로 원위치에서 다양한 오염물질들의 오염도 변화를 체계적으로 모니터링하는 것은 대단히 어렵다. 본 연구에서는 Frequency Domain Reflectometry(FDR) 장비를 고안하여 지반의 유류오염을 파악하기 위한 유전율 측정법의 실험적 접근을 시도하였다. 구체적으로 포화 및 불포화 매질에 대한 오염도의 측정 및 오염도와 체적함수비의 관계를 측정하여 유전율 반응으로부터 매질의 물성치를 파악할 수 있는 것을 확인하였다.

  • PDF

Method for Measuring Dielectric Constant of Planar Dielectric Substrate (판형 유전체의 유전율 측정 방법)

  • Lee, Chang-Hyun;Kwon, Taek-Sun;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.799-804
    • /
    • 2018
  • In this paper, a method for measuring the dielectric constant of a planar dielectric substrate using the free space material constant measurement method in a general measurement environment is proposed. Two horn antennas and a network analyzer were used for S-parameter measurement and the transmission and reflection coefficients of a planar dielectric substrate were calculated from the measurement results. To obtain a reliable dielectric constant in a low-precision-measurement environment, only the magnitude of the transmission coefficient, which has a small error due to the measurement environment, is used for dielectric constant estimation. Finally, the dielectric constant is determined by comparing the measured results at different frequencies.

Evaluation and Determination of Air Void for Asphalt Concrete using a dielectric constant measurement (유전율 측정을 통한 아스팔트 콘크리트의 공극률 추정 연구)

  • Kim, Boo-Il;Kim, Yeong-Min;Cho, In-Sun
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.95-104
    • /
    • 2009
  • This study was conducted to evaluate the relationship between the dielectric constant and air void of asphalt concrete. Standard specimens that have air voids of various range $(0%{\sim}20%)$ were used to measure the dielectric constant using parallel plate method that measures low frequency dielectric constant. From the tests, dielectric constant of asphalt concrete was tend to decrease as the frequency was increased, and the decrement slope was varied with the types of asphalt binders. Dielectric constant was decreased linearly as air void was increased from zero to twenty percent. Consequently, the effect of temperature and moisture content on dielectric constants of asphalt concrete was evaluated to develop the standard curve between dielectric constant and air void of asphalt concrete. The standard curve developed in this study can be used to calibrate or develop the algorithm of non-destructive density gauge.

  • PDF

Measurement of the permittivity of insulation oil at UHF Band using TDR Method (TDR을 이용한 극초단파 대역에서 절연유 유전율 측정)

  • Goo, Sun-Geun;Ju, Hyung-Jun;Park, Ki-Jun;Han, Ki-Seon;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.173-174
    • /
    • 2008
  • Time Domain Reflectometry(TDR) 기법을 응용하여 극초단파 대역을 포함하는 광대역 주파수범위에서 절연유의 유전율을 쉽게 측정할 수 있는 기법을 제안하였다. 수 GHz 이상의 대역에서의 절연유 유전율은 전자파를 이용한 전력용 변압기 부분방전 발생위치 추정에 필수적인 정보이나 기존의 방법으로 간단히 측정할 수 없었다. 본 기법은 동축구조에서 전자파 진행속도가 절연매질 유전율의 함수로 인가된 펄스파의 매질에 대한 동축선로에서 진행시간을 계산함으로써 유전율을 구하는 간단한 방법이다. 제안한 새로운 방법을 이용해 절연유중 1종4호 신유의 경우 광대역에서의 유전율은 2.1임을 알 수 있었다.

  • PDF

The Dielectric Properties of Cancerous Tissues (종양 조직의 유전율 특성)

  • 유돈식;김봉석;최형도;이애경;백정기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.566-573
    • /
    • 2002
  • In this paper, dielectric characteristics of pathological tissues cultivated using the xenograft method were analyzed. Since cancerous tissues were extracted from the nude mouse just before the measurements, they were maintained as fresh as living tissues in the measurements. This would be one of the advantages to get more accurate and reliable results. Dielectric properties of four cancerous tissues such as brain cancer, breast cancer, colon cancer and gastric carcinoma were measured in the frequency range between 45 MHz and 5 GHz. For the measurement of the dielectric properties, 58 xenografted samples were used. It was found that all of the cancerous tissues had the similar dielectric constant values. Comparing with the normal tissues, dielectric constant values of brain cancer, breast cancer and colon cancer were higher than those of the normal tissues except gastric carcinoma in the frequency range.