• Title/Summary/Keyword: 유압 시스템

Search Result 741, Processing Time 0.025 seconds

Pressure Ripple Reduction of Hydraulic Pump-Motor in HST (HST용 유압폄프.모터의 압력맥동 저감 특성)

    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.117-123
    • /
    • 2003
  • This paper deals with pressure ripple and noise reduction characteristics for a hydrostatic transmission(HST) consisting of a variable axial piston pump connected in an open loop to a fixed displacement axial piston motor. Pressure ripples in HST is major source of vibration, which can lead to fatigue failure of components and cause noise. In order to reduce the pressure ripple, an annular tube type hydraulic filter proposes to absorb pressure ripples with the high frequencies components to achieve better noise attenuation in HST. The basic principle tube is applied to propagation of pressure wave, reflection, absorption in cross section of discontinuity and resonance in the hydraulic pipeline. It is experimently confirmed that a hydraulic filter is absorbed to be about 30∼40dB of pressure ripple with high frequencies. These results will assist in modeling and design of noise reduction in hydraulic control systems, and here, should provide a means of designing a quieter HST.

  • PDF

Development of an Algorithm for Regulation of Inlet Blood Flow in Electrohydraulic Left Ventricular Assist Device Using Fuzzy Logic (퍼지로직을 이용한 전기유압식 좌심실 보조장치의 유입혈류량 조절 알고리즘의 개발)

  • Choi, Jae-Soon;Choi, Won-Woo;Jo, Yong-Ho;Park, Seong-Keun;Min, Byoung-Goo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.387-392
    • /
    • 1995
  • 전기 유압식 좌심실 보조장치에서 모터 전류 파형을 정보로 하여 작동기의 이완기 속도를 조절함으로써 좌심방으로부터 유입되는 혈류량을 조절하는 알고리즘을 개발하였다. 좌심실 보조장치(Left Ventricular Assist Device, LVAD)는 허혈성 심장질환 등으로 좌심실 의 혈액 박출 기능이 저하된 환자에게 시술하여 정상 상태의 심박출량을 유지할 수 있도록 하는 보조 혈액 박출 기능이이다. 전기 유압식 좌심실 보조장치에서는 혈액의 유입이 능동 적으로 이루어지므로, 좌심방 함몰로 인한 심근 손상 및 외부 공기 유입으로 인한 색전증을 방지하기 위해 유입혈류량을 현재 좌심방내의 상태에 따라 적절히 조절해 주어야 한다. 좌 심방 내의 혈액량 정도는 혈액을 유입해 내는 작동기의 이완기 동작 시에 소모되는 에너지 크기에 반영되고, 작동기를 구동하는 모터에 들어가는 전류의 크기는 작동기에 공급되는 에 너지에 비례하므로, 이전류 파형의 정보들을 통해 좌심방내의 상태를 추정해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 정보들을 통해 좌심방 내의 상태를 추정 해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 이상 유무를 판단한 뒤 에에 따라 작동기의 이완기 속도를 조절하는 알고리즘을 개발하여 모의순환장치 실험을 통해 그 실효성을 검증한 결과를 정리하였다.

  • PDF

Pipe Design for Hydraulic System in Construction Heavy Equipment by Numerical Analysis (수치해석을 통한 건설중장비 유압시스템용 파이프설계에 대한 연구)

  • Shin, Yoo In;Yi, Chung Seob;Han, Sung Gil;Lee, Ho Seong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.64-71
    • /
    • 2019
  • We herein propose a systematic design method of hydraulic pipes used in heavy construction equipment. We found that even though many design studies have been conducted regarding major hydraulic components such as pumps, cylinders, and control valves, studies regarding the optimal design of hydraulic pipes are scarce. In this study, the design of four types of pipes is considered: two high-pressure and two low-pressure pipes. First, fluid flow analysis was conducted based on oil flow and pressure for various radii of curvature. For a check-valve pipe, we considered the location of an inlet pipe. We could visualize fluid flow inside the pipe according to the flow velocity and pressure distribution. Based on fluid flow analysis, we conducted a structural analysis that revealed the stress distribution and concentration for each pipe design. We selected the best design parameters for each pipe design, fabricated the pipes, and subsequently tested them for validity.

Determination of No-Failure Test Times for the Life Test of Hydraulic System Components (유압시스템 구성품의 수명시험을 위한 무고장 시험시간의 산출)

  • Lee, S.R.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.8-13
    • /
    • 2006
  • It is very important for the manufacturers to predict the life of hydraulic system components according to the results of life tests. Since it takes too much time to test the hydraulic system components until failure, the no-failure test method is applied for the life test of them. If the shape parameter of Weibull distribution, the number of samples, the confidence level, and the assurance life are given, the no-failure test times of hydraulic system components can be calculated by given equation. Here, the procedures to obtain the no-failure test times of the hydraulic system components such as hydraulic motors and pumps, hydraulic cylinders, hydraulic valves, hydraulic accumulators, hydraulic hoses, and hydraulic filters are described briefly.

  • PDF

Comparison of Control Performance in Electro.hydraulic Servo Systems (전기.유압 서보 시스템의 제어성능 비교)

  • Kim, D.T.;Park, K.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.2
    • /
    • pp.14-20
    • /
    • 2006
  • A controller design procedure for an electro-hydraulic positioning systems has been developed using $H{\infty}$ control. The generalized plant models and weighting function for multiplicative uncertainty modelling error was presented along with $H{\infty}$ controller designs in order to investigate the robust stability and performance. Both disturbance rejection and command tracking performances were improved with the $H{\infty}$ controller, and the better uniformity of time response is achieved across wide range of operating conditions than the PID, LQR and LQG control scheme. The multiplicative uncertainty case was specifically suited for the design of an electro-hydraulic positioning control systems using $H{\infty}$ control.

  • PDF

Model Indentification and Discrete-Time Sliding Mode Control of Electro-Hydraulic Systems (전기-유압 서보 시스템의 모델규명 및 이산시간 슬라이딩 모드 제어)

  • 엄상오;황이철;박영산
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.94-103
    • /
    • 2000
  • This paper describes the model identification and the discrete-time sliding mode control of electro-hydraulic servo systems which are composed of servo valves, double-rod cylinder and load mass. The controlled plant is identified as a 3th-order discrete-time ARMAX model obtained from the prediction error algorithm, where a nominal model and modeling errors are zuantitatively constructed. The discrete sliding mode controller for 3th-order ARMAX model is designed in discrete-time domain, where all states are observed from Kalman filter. The discrete sliding mode controller has better tracking performance than that obtained from continuous-time sliding mode controller, in experiment.

  • PDF

Dynamic Analysis on the Tail Gate System for Vehicle with the Energy Regenerative Brake of Hydraulic Driven Systems (유압 구동계 에너지 재생 브레이크를 적용한 자동차 테일게이트 개폐장치에 대한 동특성 해석)

  • Choi, Soon-Woo;Huh, Jun-Young
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 2010
  • The typical trunk lid system for vehicle is composed of a hinge having 4-bar link and gas lifter. Here, the energy regenerative brake of hydraulic driven systems is applied to the tail gate system for vehicle and removed the gas lifter. The new tail gate system is composed of a hydraulic pump by electric motor, a hydraulic motor, four check valves, an accumulator, a relief valve and a directional control valve. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action. The capacity selection method of accumulator by mathematical model is based upon trial and error approach and computer simulation by AMEsim software is carried out.

  • PDF

A Parameter Sensibility Analysis of a Hydraulic Suspension System Using a Sliding Mode Control (슬라이딩 모드제어에 의한 유압 현가시스템의 설계변수 민감도 해석)

  • Kim, J.Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.2
    • /
    • pp.20-26
    • /
    • 2008
  • The most vehicle active suspension system is activated by a hydraulic source and transmission system which has nonlinear characteristics. Even though we have designed a proper controller for this system, it sometimes cannot show remarkable performance characteristics because of many factors that undercut the performance of the hydraulic system, such as nonlinearity, modelling errors, parameter variations etc. So, the robust controller that prevents a system from lowering its performance is needed. In this study, the sliding mode control which is the representative one of robust controllers is adopted to investigate system parameter sensibility. As a result, the sliding mode controller shows robustness to the system parameters variations relative to the other controllers.

  • PDF

Control of the Hydraulic System Using the Global Sliding Mode Control (전역슬라이딩모드 제어를 이용한 전기유압 시스템의 제어)

  • 최형식;김명훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.218-228
    • /
    • 2003
  • A hydraulic system is modeled as the second order differential equation with uncertain system parameters and disturbance composed of modeling errors. To Position the load of the hydraulic system to a desired point. the servo valve of the hydraulic system is controlled. As a control scheme. a global sliding mode control(GSMC) is Proposed Since the servo valve has a torque limit. the GSMC is designed to coordinate the position of the load along the minimum time trajectory within the torque limit. The Proposed control scheme can be designed with ranges of parametric uncertainties and specified torque limits. By the proposed control scheme, the closed form solution of the arriving time at the desired position can be estimated.

A Hydraulic Power Steering System Based on Electro Hydrostatic Actuator (전기 정유압 구동기를 적용한 유압식 동력 조향 시스템)

  • Li, Z.M.;Lee, J.M.;Park, S.H.;Kim, J.S.;Park, Y.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.86-94
    • /
    • 2011
  • In this paper, an electro hydraulic power steering system based on electro hydrostatic actuator (EHA) is proposed. A detailed steering model for the proposed electro hydraulic power steering system including mechanical and hydraulic subsystems is established. A conventional electro hydraulic power steering system is also modeled to evaluate the performance of the proposed power steering system such as responsiveness, assist force, command tracking and steering feel by computer simulation. From the computer simulation results, it is found that the proposed power steering system based on EHA has desirable performance.