• Title/Summary/Keyword: 유방확대

Search Result 42, Processing Time 0.021 seconds

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Effects of soft tissue stretching using negative pressure on women's breast augmentation (음압원리를 이용한 연부조직 스트레칭이 여성의 유방 확대에 미치는 영향)

  • Kim, Kyung-Yun;Lee, Eun-Ju
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.285-291
    • /
    • 2020
  • There is a growing interest in breast augmentation surgery, which can most effectively maximize femininity, among modern women around the world. However, breast augmentation surgery is considered one of the most terrifying surgeries many women are afraid of, as many cases of its side effects have been reported. As a way to provide a complementary method to deal with it, this study investigated the effects of a non-surgical breast enhancement program by stretching soft tissue of the breast. According to the results, there was no change in body weight and breast elasticity, but there were marked increases in breast cup size, breast diameter and volume of the women who used this program. The external soft tissue expansion system was found to be effective in Korean women's change of breast shape. On the other hand, users should use this system regularly for some period of time, and this would limit their social activities. Therefore, for the effective use of this system, its users should make individual efforts.

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Breast Type Classification of Breast Augmented Patients Using Photogrammetric Ratio Measurements(PRM) (유방확대 수술환자 사진의 비율 측정치를 이용한 유방유형 분류)

  • Yi, Kyong-Hwa;Sohn, Boo-hyun
    • Journal of Fashion Business
    • /
    • v.21 no.2
    • /
    • pp.61-77
    • /
    • 2017
  • Although three-dimensional measurement systems for the human body have been studied, there is still an error between the measurements by the two-dimensional measurement method and the three-dimensional scanning method. Especially, in the case of the breast, the outline is not clear. The breast is made up of subcutaneous fat and mammary gland tissue, and it is easy to deform, making it difficult to grasp the exact shape. It is also more difficult to measure photogrammetry or three-dimensional measurement because it is difficult to obtain subjects because of the shame they are reluctant to expose. In this study, the angle and length of the line connecting the measurement points of the breast detail measurement items were compared with the unchanged measurement items such as breast width and center front length using the frontal and lateral photographs taken before and after breast enlargement surgery. The results of the study are as follows. The types of breast before and after surgery were classified into two groups and showed high accuracy rate. Therefore, it was possible to classify the breast type using the frontal and lateral views of the breast, and it was found that The PRM method can distinguish the characteristics of the breast type. Therefore, it can be useful for classifying and discriminating breast types.

Radiologic Findings of Polyacrylamide Gel Mammoplasty and Its Complications: A Report of Four Case Series and Review of Literature (폴리아크릴 아마이드겔을 이용한 유방확대술과 부작용: 네 개의 증례 보고 및 문헌 고찰)

  • Jong Hee Kim;Ji-Young Hwang;Jin Hee Moon;Ik Yang;Ji Young Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.230-238
    • /
    • 2022
  • Polyacrylamide gel (PAAG) has been used for augmentation mammoplasty in certain countries, such as China or Eastern European countries. However, owing to various complications, its use is currently banned in most countries. Nevertheless, because of the migratory stream of female from these countries, we also encounter patients with PAAG mammoplasty in Korea. Owing to the various imaging features of PAAG mammoplasty, it may interfere with the identification of malignancy or other pathologic conditions. Therefore, it is important to identify the imaging findings related to PAAG mammoplasty. However, there is limited literature on the radiologic findings of complications related to PAAG mammoplasty in Korea. Herein we report four cases of PAAG mammoplasty, the complications faced, and depict various radiologic features through multimodality imaging.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

Brassiere Pattern Development for Augmentation Mammaplasty Patients (유방 확대수술 환자용 브래지어 패턴 개발)

  • Sohn, Boo-hyun;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.4
    • /
    • pp.646-660
    • /
    • 2017
  • This study provides basic data to develop a brassiere pattern that can cover the big breast of breast enlargement patients. In this study, we also showed areas of the brassiere cup pattern and the body surface of the breast on a breast enlargement patient. The results of the study are as follows. Correlation analysis was obtained between volume and body surface area and breast detail dimensions. After the correction process, we proposed a research bra pattern for breast augmentation patients. The cup-boundary in bra patterns of breast enlargement surgery patients is longer than the bra patterns of the general breast; therefore, the height of the inner and outer edges of the upper cups is higher. Also, it is necessary to set the new breast upper point when measuring the upper length in patients with breast augmentation surgery because the points of circumference of the breast are marked higher than chest circumference.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Simultaneous Nuss Operation and Mammoplasty in an Adult Patient with Pectus Excavatum - A case report - (성인 여자 오목가슴 환자에서 유방 확대술과 동시에 시행한 너스 수술 - 1예 보고 -)

  • Kim, Kyung-Soo;Cho, Deog-Gon;Cho, Kyu-Do;Jo, Min-Seop;Kang, Chul-Ung
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.523-526
    • /
    • 2008
  • Minimally Invasive repair of pectus excavatum using a metal bar, as advocated by Nuss, has been broadly accepted recently for its aesthetic aspect. There are and various treatment methods, as welt. Pectus excavatum may be accompaniedso many modified repair methods have been developed and performed. We report a case of a 33-year-old woman with pectus excavatum and breast hypoplasia, which were simultaneously corrected using a substernal steel bar and mammoplasty.