• Title/Summary/Keyword: 유량함수

Search Result 393, Processing Time 0.026 seconds

Preliminary Research of the Sedimentary Environment in Bupyeng Reservoir Region, Soyang Lake in Chuncheon - Focus on Sentinel-2 Satellite Images and in-situ data - (춘천시 소양호 상류 부평지구의 퇴적환경에 대한 선행연구 - 현장조사와 위성영상자료를 중심으로 -)

  • Kim, GeonYoung;Kim, Dain;Kim, TaeHun;Lee, JinHo;Jang, YoSep;Choi, HyunJin;Shim, WonJae;Park, SungJae;Lee, Chang-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1119-1130
    • /
    • 2018
  • Soyang Lake has been contributing to economic growth by preventing flood damage in the metropolitan area, the water level in the middle to upper flow of lake has been greatly decreased due to the drought in 2015. In order to restore the existing flow rate, Bupyungbo has been built in Bupyeong-ri, Shin Nam-myeon, Inje-gun to cause artificial changes on the sedimentary environment of Bupyeong freshwater region. Therefore, this study intends to confirm the changes of sedimentary environment since Bupyeongbo has been utilized. For this study, we used the Sentinel-2 satellite image data periodically to measure the dimension of water according to the volume of water kept near Bupyung district and analyzed the particle size and the percentage of water content of the sediments through field study. The Sentnel-2 satellite images showed us how the water surface has been changed and that during the period from September 2017 to October 2018, the minimum and maximum area of water surface was observed in June 2018 and in January 2018, respectively. In addition, we find that the smaller being the particle size, the higher having the water content and that there is higher the correlation between the water content and the grain size of the sediment layer. Hereafter, if we will acquire the drone images at Bupyung district, we expect that we will be able to measure the distribution of sediments in the same area according to different time periods and observe various kinds of sediment through field work.

Modification of WASP5 for Ungauged Watershed Management and Its Application (미계측 유역관리를 위한 WASP5 모형의 개선 및 적용성 검토)

  • Kim, Jin-Ho;Shin, Dong-Suk;Kwun, Soon-Kuk
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • This study was carried out to develop a water quality simulation model for the evaluation of an ungauged watershed. For this purpose, the WASP5 model was selected and modified. The model consists of three sub-models, LOAD-M, DYN-M, and EUT-M. LOAD-M, an empirical model, estimates runoff loadings using point and non-point source data of villages. The Geum River Estuary watershed was selected to calibrate and verify the Modified-WASP5. The LOAD-M model was established using field data of water quality and quantity at the gauging stations of the watershed and was applied to the ungauged watersheds, taking the watershed properties into consideration. The result of water quality simulation using Modified-WASP5 shows that the observed average BOD data from Gongju and Ganggyeong were 2.6 mg/L and 2.8 mg/L, and the simulated data were 2.5 mg/L and 2.4 mg/L, respectively. Generally, simulation results were in good agreement with the observed data. This study focused on formulating an integrated model for evaluating ungauged watersheds. Even though simulation results varied slightly due to limited availability of data, the model developed in this study would be a useful tool for the assessment and management of ungauged watersheds.

A Stiudy on the Deveplopment of Algorithm for the Representative Unit Hydrograph of a Watershed as a Closed Linear System. (폐선형계로 본 유역대표 단위유량도의 유도를 위한 알고리즘의 개발에 관한 연구)

  • 김재한;이원환
    • Water for future
    • /
    • v.13 no.2
    • /
    • pp.35-47
    • /
    • 1980
  • An algorithm is developed to derive a representative I hr-unit hydrograph through an analysis of rainfall-runoff relations of a watershed as a closed system. For the base flow seperation of a flood hydrograph the multi-deflection method is proposed herein, which gace better results compared with those by the existing empirical methods. A modified $\Phi$index method is also proposed in this stidy to determine the time distribution rainfall excess of a rainstorm, which is essetially a modification of the commonly used $\Phi$index method of rainfall seperation. With the so-obtained rainfall excess hyetograph and the direct runoff hydrograph a trial and error computation of the ordinates of 1 hr-unit hydrograph was executed in such a manner that the synthesized flood hydrograph closely approximates the observed one, thus resulting a unit hydrograph of a piecewise exponential function type. To verify the validity of this study the 1 hr-unit hydrographs for the Imha and Dongchon in Nagdong River basin, and Yongdam in Geum River basin were derived by this algorithm, and the results were compared with those by the conventional synthetic unit hydrograph method and the Nakayasu method. Besides, the validity of this stiudy was also tested by comparing the observed hydrograph with the one computed by applying the unit hydrograph to a specific rainfall event. To generalize the result of this study a computer program, consisited of a main and three subprograns (for rainfall excess estimation, convolution summation, and sorting), is developed as a package, which is believed to be applicable to other watersheds for the similar purpose as those in this study.

  • PDF

Framework for Optimum Scale Determination for Small Hydropower Development Using Economic Analysis (경제성분석에 의한 소수력 개발의 최적규모 결정 방안)

  • Kim, Kil-Ho;Yi, Choong-Sung;Lee, Jin-Hee;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.12
    • /
    • pp.995-1005
    • /
    • 2007
  • This study presents a framework for optimum scale determination for small hydropower development in a river basin. The framework includes the construction of hydrology and topography data, the simulation of hydropower operation, the economic analysis, and the determination of optimum scale of the small hydropower. The optimum scale of design flow and facility are determined by Net Present Value among economic analysis indices. The investment cost is estimated by the cost function derived from the construction cost of existing small hydropower plants. The benefit from power generation is estimated by the price announced by government. The presented framework is applied to the two potential sites in Cho River basin for the dam and run-of-river type of plants. Finally, the sensitivity analysis for a design flow and scale of the plant is performed for the each site. The usage of the framework presented in the study is highly expected for the estimation of potential hydropower resources or the decision support tool for a proprietor by estimating the optimum scale and economical feasibility in advance.

Scenario-based Flood Disaster Simulation of the Rim Collapse of the Cheon-ji Caldera Lake, Mt. Baekdusan (시나리오에 따른 백두산 천지의 외륜산 붕괴에 의한 홍수재해 모의)

  • Lee, Khil-Ha;Kim, Sang-Hyun;Choi, Eun-Kyeong;Kim, Sung-Wook
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.501-510
    • /
    • 2014
  • Volcanic eruptions alone may lead to serious natural disasters, but the associated release of water from a caldera lake may be equally damaging. There is both historical and geological evidence of the past eruptions of Mt. Baekdusan, and the volcano, which has not erupted for over 100 years, has recently shown signs of reawakening. Action is required if we are to limit the social, political, cultural, and economic damage of any future eruption. This study aims to identify the area that would be inundated following a volcanic flood from the Cheon-Ji caldera lake that lies within Mt. Baekdusan. A scenario-based numerical analysis was performed to generate a flood hydrograph, and the parameters required were selected following a consideration of historical records from other volcanoes. The amount of water at the outer rim as a function of time was used as an upper boundary condition for the downstream routing process for a period of 10 days. Data from the USGS were used to generate a DEM with a resolution of 100 m, and remotely sensed satellite data from the moderate-resolution imaging spectroradiometer (MODIS) were used to show land cover and use. The simulation was generated using the software FLO-2D and was superposed on the remotely sensed map. The results show that the inundation area would cover about 80% of the urban area near Erdaobaihezhen assuming a 10 m/hr collapse rate, and 98% of the area would be flooded assuming a 100 m/hr collapse rate.

A Study on Verification of Delivery Ratio Methodology for Basic Plan at TPLMs(Total Pollutant Load Management System) (수질오염총량관리계획 수립을 위한 유달율 적용방안 검증 연구)

  • Lee, Sung Jun;Rhee, Han Pil;Park, Ji Hyung;Kim, Yong Seok;Hwang, Ha Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.714-722
    • /
    • 2017
  • The TPLMs is a system to manage the total amount of pollutants discharged from the watershed in order to achieve the target water quality of the river. In this process, the pollutant load can be classified into generation, discharge and delivery load. When using equation 2, the discharge coefficient should be 1. In case of using equation 3, it is considered that the discharge coefficient defined in the Technical Guideline should be applied. The delivery load is calculated as the product of the discharge load and the delivery ratio, and the delivery ratio is defined as the rate at which the pollutant discharged from the watershed reaches a specific point in the stream. In this study, the delivery ratio estimation method proposed by Hwang (2016) was applied to the Yonggang watershed in the Nakdong river. And the input data of QUALKO2 model was generated by using the estimated delivery ratio (equation 3) and the validation study was conducted by comparing with DRave (equation 2). As a result of the study, it is possible to use both the equation 2 and the equation 3, but it is necessary to change the methodology according to the application of the discharge coefficient.

A LQR Controller Design for Performance Optimization of Medium Scale Commercial Aircraft Turbofan Engine (II) (중형항공기용 터보팬 엔진의 성능최적화를 위한 LQR 제어기 설계 (II))

  • 공창덕;기자영
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.3
    • /
    • pp.99-106
    • /
    • 1998
  • The performance of the turbofan engine, a medium scale civil aircraft which has been developing in Rep. of Korea, was analyzed and the control scheme for optimization the performance was studied. The dynamic and real-time linear simulation was performed in the previous study The result was that the fuel scedule of the step increase overshoot the limit temperature(3105 $^{\cire}R$) of the high pressure turbine and got small surge margine of the high pressure compressor. Therefore a control scheme such as the LQR(Linear Quadratic Regulator) was applied to optimizing the performance in this studies. The linear model was expected for designing controller and the real time linear model was developed to be closed to nonlinear simulation results. The system matrices were derived from sampling operating points in the scheduled range and then the least square method was applied to the interpolation between these sampling points, where each element of matrices was a function of the rotor speed. The control variables were the fuel flow and the low pressure compressor bleed air. The controlled linear model eliminated the inlet temperature overshoot of the high pressure turbine and obtained maximum surge margins within 0.55. The SFC was stabilized in the range of 0.355 to 0.43.

  • PDF

Optimization of Stream Gauge Network Using the Entropy Theory (엔트로피 이론을 이용한 수위관측망의 최적화)

  • Yoo, Chul-Sang;Kim, In-Bae
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.2
    • /
    • pp.161-172
    • /
    • 2003
  • This study has evaluated the stream gauge network with the main emphasis on if the current stream gauge network can catch the runoff characteristics of the basin. As the evaluation of the stream gauge network in this study does not consider a special purpose of a stream gauge, nor the effect from a hydraulic structure, it becomes an optimization of current stream gauge network under the condition that each stream gauge measures the natural runoff volume. This study has been applied to the Nam-Han River Basin for the optimization of total 31 stream gauge stations using the entropy concept. Summarizing the results are as follows. (1) The unit hydrograph representing the basin response from rainfall can be transferred into a probability density function for the application of the entropy concept to optimize the stream gauge network. (2) Accurate derivation of unit hydrographs representing stream gauge sites was found the most important part for the evaluation of stream gauge network, which was assured in this research by comparing the measured and derived unit hydrographs. (3) The Nam-Han River Basin was found to need at least 28 stream gauge stations, which was derived by considering both the shape of the unit hydrograph and the runoff volume. If considering only the shape of the unit hydrograph, the number of stream gauges required decreases to 23.

NPS runoff reduction analysis in accordance with the slope of the tillage method (경운방법의 경사도에 따른 비점오염원 유출 저감 효과 분석)

  • Jeon, Je Hong;Won, Chul Hee;Moon, Sang Gi;Lee, Su In;Choi, Jung Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.425-425
    • /
    • 2015
  • 본 연구는 밭에서 발생하는 비점오염원의 저감 효과를 분석하기 위하여 최적관리기법(BMPs) 중 경운방법과 침투짚단을 하여 효과를 분석하고자 하였다. 시험포 1개의 면적은 $150m^2$ (폭 5 m, 경사장 30 m)이며, 모두 사질토의 특성을 가진 토양이다. 시험포는 총 8개(경사도 3% 4개, 8% 4개)로 각각 무경운 시험포 2개와 경운 시험포 1개 그리고 침투 짚단을 설치한 경운 시험포 1개로 경사도와 영농방법을 다르게 조성하였다. 실험의 오차를 줄이기 위하여 강우지속시간과 강우량 그리고 강우강도가 일정한 인공강우 실험을 수행하였으며, 실험시 바람에 의한 강우량의 오차를 줄이기 위해 날씨가 맑은 날에 실시하였다. 또한, 선행무강우일수 7일로 유지하여 토양의 함수비를 동일한 조건이 되도록 하였다. 총 3회의 인공강우실험에서 강우강도는 30 mm/hr 이였으며, 강우로 인해 발생한 유출수는 수위를 측정한 뒤, 수위-유량곡선식을 이용하여 유량으로 환산하였으며, 이때 수질시료를 채취하였다. 채취된 수질시료는 $BOD_5$, $COD_{Cr}$, $COD_{Mn}$, TN, TP, DOC 등의 6개 항목을 분석하였다. 연구결과 경사도 3%의 침투짚단 시험포에서 오염부하는 경운 시험포 대비 $BOD_5$는 25.4%, $COD_{Cr}$은 20.5%, $COD_{Mn}$은 2.1%, DOC는 40.8%, 영양염류인 TN과 TP는 각각 23%와 8.7%가 저감되는 것으로 나타났다. 또한 경사도 3%의 무경운 시험포에서 오염부하는 경운 시험포 대비 $BOD_5$는 57.5%, $COD_{Cr}$은 59.8%, $COD_{Mn}$은 65%, TN과 TP는 65.4%와 75%로 저감되었다. 그리고 경사도 8%에서 경운 시험포대비 침투짚단 시험포의 오염부하는 $BOD_5$ 19.6%, $COD_{Cr}$$COD_{Mn}$은 각각 7.8%와 10% 그리고 영양염류인 TN은 15.5%, TP는 11.2%가 저감되는 것으로 나타났다. 경사도 8%에서 무경운 시험포에서는 경운 시험포 대비 $BOD_5$ 70.9%, $COD_{Cr}$$COD_{Mn}$은 각각 74.9%와 81.3% 그리고 영양염류인 TN은 70.2%, TP는 70.1%가 저감된 것으로 나타났다. 본 연구결과와 같이 경운을 하는 관행방법에 비해 토양의 침투능이 유지할 수 있는 무경운 방법이나 침투짚단을 활용하는 방법이 밭에서 발생하는 비점오염원을 저감할 수 있는 것으로 나타났다. 그러나, 본 연구의 결과는 3번의 인공강우 실험을 통해 분석된 결과로써 추가적인 연구를 통해 다양한 경사도와 영농방법에 따른 비점오염물질의 저감효과를 분석해야 할 것으로 보여진다.

  • PDF

Analysis of Rainfall-Runoff Characteristics in Gokgyochun Basin Using a Runoff Model (유출모형을 이용한 곡교천 유역의 강우-유출 특성 분석)

  • Hwan, Byungl-Ki;Cho, Yong-Soo;Yang, Seung-Bin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.404-411
    • /
    • 2019
  • In this study, the HEC-HMS was applied to determine rainfall-runoff processes for the Gokgyuchun basin. Several sub-basins have large-scale reservoirs for agricultural needs and they store large amounts of initial runoff. Three infiltration methods were implemented to reflect the effect of initial loss by reservoirs: 'SCS-CN'(Scheme I), 'SCS-CN' with simple surface method(Scheme II), and 'Initial and Constant rate'(Scheme III). Modeling processes include incorporating three different methods for loss due to infiltration, Clark's UH model for transformation, exponential recession model for baseflow, and Muskingum model for channel routing. The parameters were calibrated using an optimization technique with trial and error method. Performance measures, such as NSE, RAR, and PBIAS, were adopted to aid in the calibration processes. The model performance for those methods was evaluated at Gangcheong station, which is the outlet of study site. Good accuracy in predicting runoff volume and peak flow, and peak time was obtained using the Scheme II and III, considering the initial loss, whereas Scheme I showed low reliability for storms. Scheme III did not show good matches between observed and simulated values for storms with multi peaks. Conclusively, Scheme II provided better results for both single and multi-peak storms. The results of this study can provide a useful tool for decision makers to determine master plans for regional flood control management.