Browse > Article
http://dx.doi.org/10.4491/KSEE.2017.39.12.714

A Study on Verification of Delivery Ratio Methodology for Basic Plan at TPLMs(Total Pollutant Load Management System)  

Lee, Sung Jun (Water Environmental Research Department, National Institute of Environmental Research)
Rhee, Han Pil (ETWATERS Inc.)
Park, Ji Hyung (Water Environmental Research Department, National Institute of Environmental Research)
Kim, Yong Seok (Water Environmental Research Department, National Institute of Environmental Research)
Hwang, Ha Sun (Water Environmental Research Department, National Institute of Environmental Research)
Publication Information
Abstract
The TPLMs is a system to manage the total amount of pollutants discharged from the watershed in order to achieve the target water quality of the river. In this process, the pollutant load can be classified into generation, discharge and delivery load. When using equation 2, the discharge coefficient should be 1. In case of using equation 3, it is considered that the discharge coefficient defined in the Technical Guideline should be applied. The delivery load is calculated as the product of the discharge load and the delivery ratio, and the delivery ratio is defined as the rate at which the pollutant discharged from the watershed reaches a specific point in the stream. In this study, the delivery ratio estimation method proposed by Hwang (2016) was applied to the Yonggang watershed in the Nakdong river. And the input data of QUALKO2 model was generated by using the estimated delivery ratio (equation 3) and the validation study was conducted by comparing with DRave (equation 2). As a result of the study, it is possible to use both the equation 2 and the equation 3, but it is necessary to change the methodology according to the application of the discharge coefficient.
Keywords
TPLMs; Discharge Load; Delivery Load; Delivery Ratio; Water Quality Model;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Hwang, H. S., Rhee, H. P., Park, J. H., Kim, Y. S., Lee, S. J. and Ahn, K. H., "Study on Estimatioon and Application of Discharge Coefficient about Nonpoint Source Pollutants using Watershed Model," J. Korean Soc. Water Environ., 31(6), 653-664(2015).   DOI
2 National Institute of Environmental Research, "The technical guideline for Total water Pollutant Load Management System," NIER, NIER-GP2014-057(2014).
3 Hwang, H. S., Rhee, H. P., Ahn, K. H., Park, J. H., Kim, Y. S. and Lee, S. J., "A Study on Estimated Pollutant Delivery Load for the Basic Plan of TPLC," J. Korean Soc. Water Environ., 32(4), 375-383(2016).   DOI
4 Park, J. W., Kim, K. S., Hwang, K. S., Lee, Y. W. and Lim, B. J. "Application of Load Duration Using Discharge-Load Rating Curve at Jiseok Stream Watershed," J. Korean Soc. Water Environ., 29(4), 523-530(2013).
5 Choi, D. H., Jung, J. W., Lee, K. S., Choi, Y. J., Yoon, K. S., Cho, S. H., Park, H. N., Lim, B. J. and Chang, N. I., "Estimation of Pollutant Load Delivery Ratio for Flow Duration Using L-Q Equation from the Oenam-cheon watershed on Junam Lake," J. Environ. Sci., 21(1), 31-39(2012).
6 Jung, J. W., Lim, B. J., Choi, D. H., Choi, Y. J., Lee, K. S., Kim, Y. J., Kim, K. S., Chang, N. I. and Yoon, K. S., "Evaluation of Flow-Pollutant Load Delivery Ratio Equation on Main Subwatersheds within Junam Lake," J. Environ. Sci., 21(10), 1235-1244(2012).
7 Park, J. H., Hwang, H. S., Rhew, D. H. and Kwong, O. S., "Estimation of Delivery Ratio Based on BASINS/HSPF Model for Total Maximum Daily Load," J. Korean Soc. Water Environ., 28(6), 833-842(2012)
8 Kang, J. H., Hong, J. J., Kim, S. G., Son, M. S., Lee, Y. J. and Lim, B. J., "A Study Calculating of Delivery Ratio Daily WinHSPF/BASINS Model," J. Korean Soc. Water Sci. and Technol., 18(5), 19-28(2010).
9 Gyeongsanbuk-do., "The Third Stage Basic Plan of Gyeongsanbuk-do TMDL in Nakdong River," Gyeongsanbuk-do(2015).
10 Shon, T. S., Park, J. B. and Shin, H. S., "A Study on Estimation of the Delivery Ratio by Flow Duration in a Small-Scale Test Bed for Managing TMDL in Nakdong River." J. Korean Soc. Water Qual., 25(5), 792-802(2009).