• Title/Summary/Keyword: 유량측정 검증시스템

Search Result 82, Processing Time 0.025 seconds

Improvement in flow and noise performances of small axial-flow fan for automotive fine dust sensor (차량용 미세먼지 센서용 소형 축류팬의 유동과 소음 성능 개선)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Inhiug Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.7-15
    • /
    • 2023
  • Recently, as interest in air quality in vehicles increases, the use of fine dust detection sensors for air quality measurement is becoming common. An axial-flow fan is inserted in the fine dust sensor installed in the air conditioning system in the vehicle to prevent dust from sinking directly on the sensor. When the sensor operates, the flow noise caused by the rotation of the axial-flow fan acts as a major noise source of the fine dust sensor. flow noise is recognized as one of the product competitiveness of fine dust sensors. In this study, the noise was gradually reduced at the same flow rate by improving the flow performance of the small axial flow fan. First, a virtual fan performance tester consisting of about 20 million grids was developed to analyze the aerodynamic performance of the target small axial-flow fan. In addition, the flow field was simulated by using compressible Large Eddy Simulation for direct computation of flow noise as well as high-accurate prediction of flow rate. The validity of numerical method are confirmed through the comparison of predicted results with experimental ones. After the effects of pitch angle on flow performance were analyzed using the verified numerical method, the pitch angle was determined to maximize the flow rate. It was found that the flow rate was increased by 8.1 % and noise was reduced by 0.8 dBA when the axial-flow fan with the optimum pitch angle was used.

Development of Correction Algorithm of Swayed Images for LSIV (LSIV를 위한 흔들리는 영상의 보정 알고리듬의 개발)

  • Yu, Kwon-Kyu;Yoon, Byung-Man;Kim, Ju-Whang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.494-499
    • /
    • 2006
  • LSIV (Large Scale Image Velocimetry)는 영상 처리 기술을 이용하여 수표면의 유속을 측정하는 장비이다. 처리가 용이한 좋은 LSIV의 영상을 만들기 위해서는 높은 고도에서 내려다 보며 영상을 획득하는 것이 측정의 정밀도를 높이는 데 도움이 된다. 이를 위해 트럭에 장착된 기중기를 이용하는 이동용 LSIV를 개발하고 있다. 이 때 기중기의 흔들림에 따라 획득된 영상이 흔들리는 문제가 발생하며, 영상의 흔들림을 보정하여 유속을 측정할 수 있는 영상 처리 알고리듬이 필요하게 된다. 이 연구에서는 PTV(Particle Tracking Velocimetry)의 입자 추적 알고리듬과 LSIV의 좌표 변환 알고리듬, LSIV의 유속 산정 알고리듬을 조합하여 흔들리는 영상에서 표면 유속을 측정하는 알고리듬을 개발하였다. 입자 추적 알고리듬은 비디오 카메라로 촬영된 연속 영상의 참조점들의 움직임을 추적하여 카메라의 위치 변동을 파악한다. 영상 분석된 결과들을 이러한 참조점들을 기준으로 변환하였다. 개발된 알고리듬의 검증을 위해서 실험 수로에서 동일한 흐름에 대해 흔들리지 않은 영상과 흔들리는 영상의 두 가지 영상을 만들었다. 흔들림이 없는 영상의 처리결과를 기준으로 삼아, 흔들림이 있는 영상의 처리 결과를 검토하였다. 그 결과, 흔들림이 지나치게 커서 참조점들의 추적이 불가능한 경우를 제외하고는 두 자료의 처리 결과는 거의 동일하였으며, 유속 측정의 최대 오차는 약 5 % 내외로 나타났다. 이 오차는 흔들림 때문에 생기는 영상의 열화 때문으로 추정된다. 이 알고리듬은 이동용 LSIV 시스템에 효율적으로 활용될 수 있을 것으로 기대된다.비용적 측면이나 생태 보존적 측면에서 유리할 것으로 판단된다.one)을 설치하는 대책이 필요하다. 저수지 관리를 효과적으로 수행하기 위해서는 저수지 내부의 탁도 거동을 정확히 예측할 수 있어야 한다. 따라서 추후 동수역학 및 열역학에 기초한 3차원 수치모형 연구와 성층흐름에 정밀한 밀도류 실험연구 및 이에 대한 적용이 필요할 것으로 판단된다.함으로써 정보의 질적보장과 정보전환의 표준화방안을 제시하는 정보분석시스템이다.이용, 수자원의 지속적 확보기술의 특성에 따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익

  • PDF

Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance (제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가)

  • Lee, Yeon-Gun;Heo, Jaehyeok;Lee, Dong-Won;Hyun, Myung-Taek
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.70-79
    • /
    • 2018
  • A heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO was constructed with the capacity of 300 RT to supply cool or hot water to greenhouse facilities located 3 km from the power station. The way of transporting heat from the thermal effluent to greenhouses at a long distance was optimized, and a monitoring system to measure the water temperature and detect a leakage in a pipe conduit was also installed. This paper presents the system configuration of the constructed heat pump system for air conditioning and heating of greenhouse facilities in Jeju, and the characteristics of major components deployed in the system. The preoperational tests of the heat pump system were conducted during the summer season in 2018 for evaluation of its cooling performance. The operational stability and cooling performance of the heat pump system were confirmed by investigating the measured fluid temperature and flow rate, and COP of the heat pump in a cooling mode.

Dynamic modeling of the hydraulic-thermal behavior of the buried pipe network for district heating (지역난방용 지중매설 배관망 네트워크 열-유체 동적 거동 모델링)

  • Lee, Jeongbin;Yi, Jun Young;Kim, Lae-Hyun;Shin, Chee Burm
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.144-151
    • /
    • 2012
  • A district heating system produces thermal energy and supplies it to a large region. District heating systems can provide higher efficiencies and better pollution control than localized boilers. The heat generated by a district heating system is distributed to the customer via a network of insulated pipes. For the optimal operation of a district heating system, it is important to predict the distributions of pressure, flow rate and temperature of heating fluid within the network of pipes at various operating conditions. In this work, a mathematical modeling was performed to predict the dynamic hydraulic-thermal behaviors of heating fluid in the network of pipes for a district heating system. The mathematical model accounts for the conservations of mass, momentum and energy. In order to verify the validity of modeling, the modeling results were compared with the monitoring data of Gang-nam Branch of District Heating.

Design and Performance Estimation of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner (열처리로용 소형 축열식 복사관 버너의 축열기 설계 기술평가)

  • Cho H. C.;Cho K. W.;Lee Y. K.
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.291-295
    • /
    • 2004
  • Heat regenerator attached in small-scale regenerative radiant tube burner was designed using the theoretical computation code and was confirmed the performance of waste heat recovery ratio. From the computation, when ceramic ball of 4-5kg was used, temperature efficiency and available waste heat recovery ratio were predicted 80% and 70%, respectively. Similar efficiencies were obtained from the experiments using LPG. However, since exhaust gas temperature entered into regenerator was below 850$^{\circ}C$ which was moth lower than that we expected. air preheating temperature was lowered below 800$^{\circ}C$.

Optimal Design of Impeller according to Blade Shape Variation Using CFD Simulation (CFD를 이용한 블레이드 형상 변화에 따른 블로워 임펠러 최적설계)

  • Yu, Da-Mi;Kim, Semo;Jang, Hye-Lim;Han, Dae-Hyun;Kang, Lae-Hyong
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.1
    • /
    • pp.29-37
    • /
    • 2019
  • The objective of this study was to investigate the influence of the blade shape on the impeller performance, for design optimizing of the high airflow impeller. First, the quantity, angle, and length of blades, which are considered to have a large influence on the impeller performance, were selected as design variables. Then, 27 cases of impeller shapes were selected according to the design of experiment (DOE). To predict the conduct of the blower based on the selected impeller shape, flow analysis was performed using the immersed solid method of ANSYS CFX. In the CFD results, the highest airflow was expected in the impeller having a combination of 50 EA, $6^{\circ}$ and 5 mm. Finally, a blower with the original impeller shape and the optimized impeller shape was fabricated using a 3D printer, and the analysis tendency and experimental tendency were verified through experiments.

Optimization of flow performance by designing orifice shape of outdoor unit of air-conditioner (에어컨 실외기 냉각팬 시스템의 오리피스 형상 설계를 통한 유량 성능 최적화)

  • Ryu, Seo-Yoon;Kim, Sanghyeon;Cheong, Cheolung;Kim, Jong-Uk;Park, Byeong Il;Park, Se Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.371-377
    • /
    • 2017
  • The performance of an air conditioner is closely related to the cooling performance of a split-type outdoor unit so that, in most of the relevant preceding studies, the independent performance of an axial fan in an outdoor unit has been studied. However, there is a lack of research on the effects of other components in an outdoor units was rarely investigated. Therefore, in this paper, the effects of the fan orifice among other parts on the flow performance of the outdoor unit was numerically investigated. A virtual fan tester consisting of 18 million grids was developed for highly resolved flow simulation. The unsteady RANS (Reynolds-averaged Navier-Stokes) equations are numerically solved by using finite-volume CFD (Computational Fluid Dynamics) techniques. In order to verify the validity of the numerical methods, the predicted P-Q curve of the cooling fan in a full outdoor unit is compared with the measured one. Optimization of orifice shape was carried out for maximum flow performance of the outdoor unit using the validated numerical method.

Turbid Water Simulation Model for Downstream of the Imha and Andong Dam (임하 및 안동댐 하류하천 탁도모의 시스템 구축)

  • Noh, Joon-Woo;Kim, Jeong-Kon;Lee, Sang-Uk;Park, Sang-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1115-1119
    • /
    • 2007
  • 우리나라는 몬순기후대에 속하여 매년 홍수가 발생하고 이시기에 저수지로 유입된 탁수로 말미암아 저수지 인근 및 하류하천에 거주하는 주민들의 민원의 대상이 되고 있다. 이에 따라 유역, 저수지, 및 하천을 포함한 포괄적인 대책을 수립하기 위하여 유역과 저수지 그리고 저수지와 하천을 연계한 통합시스템을 구축함으로써 탁수의 거동을 고려한 저수지 운영에 대한 의사결정을 지원하고자 한다. 본 연구에서는 안동 및 임하댐의 연계운영을 통한 하류하천 탁도관리 방안을 수립하고자 동적수질모형인 Koriv1-win 모형을 구축하여 저수지 수질모의 시스템과 연계 가능하도록 하였다. 모형은 안동댐하류로부터 구미수위표 지점까지 134 km에 달하는 구간에 대하여 구축하였으며 대상구간 내에는 내성천을 비롯 5개의 주요지천이 존재하게 된다. 그림 1에는 수리모듈 및 수질모듈의 검증결과를 나타내고 있으며 탁도모의결과를 검증하기 위하여 임하댐 관리단에서 측정한 자료를 이용하였다. 수리해석결과 구미지점의 유량변동을 잘 반영하는 것으로 모의되었고 수질해석결과도 관측치와 상당히 비슷하게 나타나는 것을 알 수 있었다. 한편 안동댐방류수와 임하댐 방류수가 혼합되는 영역에서 2차원적 흐름양상과 각 댐으로부터 방류되는 방류수의 수온과 탁도의 혼합양상을 모의하였으며 실측을 통하여 모의결과와 비교해 보았다. 저수지 하류하천에 대하여 1차원 및 2차원적 수리해석과 수질해석결과를 통하여 하천에서의 탁수전파 거리 및 고탁도 탁수의 도달 시간을 산정할 수 있도록 함으로써 저수지 연계운영을 통한 하류단 탁도저감에 대한 계획수립이 가능하다.을 것으로 판단된다. 철거 선정 체계는 보 철거를 위해서 보 주변 지역 거주민을 설득하며, 하천의 환경 개선을 위한 합리적인 대안 제시를 목적으로 하고 있다. 선정 체계를 바탕으로 주민 협의 및 대안 제시를 통해 결정된 대상 보는 선정 체계 안에서 보 철거 영향 판단 절차에 따라서 보 철거로 인한 수문, 수리, 지형, 수질, 생태 영향을 판단하게 되며, 이와 더불어 사회 경제적인 영향을 평가하게 된다. 평가결과에 따라서 보를 완전히 철거하거나 다른 대안을 고려하여 보를 부분적으로 철거하거나 개량하게 된다.곳으로 1/3의 자기 생산을 담당하고 있었다. $\ulcorner$경상도지리지$\lrcorner$(慶尙道地理志)에는 $\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와 동년대에 동일한 목적으로 찬술되었음을 알 수 있다. $\ulcorner$경상도실록지리지$\lrcorner$(慶尙道實錄地理志)에는 $\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와의 비교를 해보면 상 중 하품의 통합 9개소가 삭제되어 있고, $\ulcorner$동국여지승람$\lrcorner$(東國與地勝覽) 에서는 자기소와 도기소의 위

  • PDF

Return Flow Analysis of Irrigation for a Paddy Field at the Downstream of the Yangak Reservoir (양악저수지하류에서의논농업용수회귀율조사)

  • Lee, Hyun-Seok;Chai, Won-Ki;Kim, Young-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.292-292
    • /
    • 2011
  • 전라북도 장수군 계북면 양악리 토옥동계곡의 초입에 위치한 양악호는 농업용 저수지로 관개수로를 통하여 약 $3.94\;km^2$의 몽리면적에 용수를 공급한다. 양악호는 1985년 건설공사를 시작하여 1991년에 준공되었다. 관개수로를 통해 공급된물은 다양한 경로를 통해 양악천으로 회귀되며, 회귀수량은 양악호로부터 약 8 km 하류에 위치한 양악1교에서 관측된다. 연구 대상지역은 행정구역상 전라북도 장수군, 무주군과 진안군이 경계를 이루며, 유역의 대표적인 거주지로는 당저, 파곡, 외림 그리고 주고마을이 있다. 본 논문에서는 용담댐 상류에 위치한 양악천 유역을 대상으로 관개수로를 통한 유입량, 하류하천에서의 배수량, 양악천 상류 양악호에서의 강수량, 농지에서의 경작현황 및 몽리면적 등 실측자료를 활용하여 농업용수 회귀율을 분석하였다. 농지의 면적은 현장에서의 직접조사 및 위성영상을 활용한 간접조사를 통하여 수혜지역으로부터 '인삼 재배 면적'을 제외하는 방법으로 산출하였다. 관개수로를 통한 용수공급이 없는 시기의 하천유지유량은 용수의 유입이 없는 1월부터 4월초까지의 자료를 분석하여 산정하였다. 하류하천에서의 배수량은 홍수기 전 후로 구분하여 조사하였다. 양악천 유역내 강우자료는 양악호 취수탑 입구에 설치된 우량계를 이용하여 측정하였으며, 원촌교 인근의 계북 우량관측소 자료를 검증용으로 활용하였다. 양악천 유역은 유역외 용수공급을 위하여 양수장을 운영하고 있으며, 생활용수 공급 시스템은 장수군, 무주군과 진안군 등 행정구역별로 각각 다르다. 그러므로 회귀율 산정시 양수장 운영일지 및 마을 일부의 정화조 사용량을 참고하였다. 양악천유역에서는 4월 말부터 9월 말까지 약 5개월간 용수공급이 이루어졌다. 초 여름인 6월 28일 부터 7월 03일까지의 회귀율이 43.66 %로 최저로 나타났으며, 4월 30일부터 5월 16일까지는 67.77 %로 제일 높게 분석되었다. 분석 결과 이 지역은 6월 말에서 7월 초순을 제외한 대부분의 기간에는 약 55 ~ 60 % 사이의 비교적 높은 회귀율을 보였다. 2010년 양악천 유역 전구간의 평균 회귀율은 56 %이며, 무강우시 회귀율 분석결과는 다음과 같다.

  • PDF

A Waste Load Allocation Study for Water Quality Management of the Incheon Coastal Environment (인천해안의 수질관리를 위한 오염부하량 할당에 관한 연구)

  • Kim, So-Yeon;Choi, Jung-Hyun;Na, Eun-Hye;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • This paper presents a waste load allocation study for the Incheon coastal environment, where a computer model, called AQUASEA, was applied. A finite element mesh was constructed and refined to cover the complicated geometry of Incheon coastal sea. The tidal height at 13 places of Incheon coastal boundary and flow of the Han River were given as an input condition to the tidal simulation. All pollution sources that discharge into Incheon coast were given as input data to the water quality simulation. The modeled parameters include tidal flow and COD(Chemical Oxygen Demand). The model was calibrated and verified with the field measurements. The model results showed reasonable agreements with field measurements in both tidal flow and water quality. Systems analysis showed that the pollution load from the Han River caused recognizable impacts on the water quality of Incheon coast from Yeomhwa waterway to northern area of Younghungdo. The loads from Incheon City affected water quality from the area below Youngjongdo to the area above Jawalldo. The discharge from the Sihwa Lake caused discernible impacts on the coastal zone from the dike outlet to the Incheon harbor, and pollution loads from Kyungkido affected the sea near the Oido. An effective water quality management plan was developed from the waste load allocation analysis of the validated model, that the maximum waste loads can be discharged without violating the water quality standard given in the Incheon coastal environment.