• Title/Summary/Keyword: 유동손실

Search Result 574, Processing Time 0.026 seconds

A Numerical Analysis of the Partial Admission Supersonic Turbine Losses for Geometic Conditions (형상 변수에 따른 부분 흡입형 초음속 터빈 손실에 관한 수치적 연구)

  • Shin Bong-Gun;Im Kang-Soo;Kim Kui-Soon;Jeong Eun-Hwan;Park Pyun-Goo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.297-305
    • /
    • 2006
  • In this paper, numerical analyses of the flow within turbine for geometric conditions such as nozzle shape, length of axial clearance, and chamfer angle of leading edge of blade have been performed to investigate the partial admission supersonic turbine losses. Firstly, flow's bending occurred at axial clearance is depended on nozzle shape. Next, the chamfer angle of leading edge affects the strength of shock generated at the leading edge. Finally the expansion and mixsing of the flow within axial clearance are largely depended upon the length of axial clearance. Therefore it is found that aerodynamic losses of turbine is affected by nozzle shape and chamfer angel and that partial admission losses is depended on nozzle shape and the length of axial clearance.

  • PDF

공동형상에 따른 경사충격파와 경계층 상호작용의 피동제어 성능 비교 연구

  • Kim, Hong-Gyu
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.604-609
    • /
    • 2016
  • 슬롯판을 이용한 경사충격파와 경계층 간섭유동 제어에서, 슬롯판 아래에 있는 공동부의 형상을 바꾸어 가며 제어 성능을 비교하는 수치적 연구가 수행되었다. 공동형상 직사각형 5개, 사다리꼴 3개를 선정하여 shock 뒤에서 경계층 안정성, 전압손실을 기준으로 제어 성능을 평가하였다. 수치해석 결과 모든 형상에 대해 제어하지 않은 상태보다 좋은 성능을 얻었다. 그 중 경계층 안정성 측면에서는 형상 L과 R, 전압손실 감소 측면에서는 형상 M과 A가 효과적임을 확인하였고, 종합적으로 슬롯의 끝 면과 공동의 길이방향 끝 면이 일치하는 형상에서 상대적으로 좋은 결과를 얻음을 확인했다. 또한 슬롯과 공동 내부유동을 분석하면서 경계층 안정성과 전압손실 감소에 영향을 미치는 것은 separation 영역을 얼마 원활히 흡입하는지의 여부임을 알 수 있었고, 상류 슬롯에서 발생하는 shock에 대한 추후 해결 연구도 필요함을 알 수 있었다.

  • PDF

Bingham Charateristics of Electrorheological Fluid and Its Application to ER valve and ER Damper (전기유변유체의 빙햄특성과 밸브 및 댐퍼에의 응용)

  • 배종인
    • The Korean Journal of Rheology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 1998
  • 전기장이 인가되고 있는 유로를 유동하는 전기유변유체의 기본성질을 파악하기 위 한 실험 및 해석적 연구를 수행하여 빙햄유체로서의 유효성에 대해 알아보고 전기장과 유로 면 형상 및 진동유동으로 인한 영향에 대해 조사함으로써 ER밸브 및 ER대퍼로의 응용과 관련한 감쇄력 제어에 대해 검토하였다. 첫 번째 실험은 ER밸브의 높이가 2mm인 적극면이 평탄한것과 요철로 된 것을 사용하여 압력손실을 압력변환기로 측정함으로써 전기장 및 유 로형상에 대한 영향을 알아보았다. 압력손실 및 전단응력이 전기자세기와 함수관계를 가짐 을 알수 있었고 전기장세기와 유속의 변화시 손실계수에 의한 ER효과의 상이함이 확인되었 으며 레이놀즈수가 커지면 항복전단응력의 영향은 나타나지 않았다. 두 번째 실험은 실린더 를 정현파로 진동시켜 ER밸브에서 감쇠력제어가 가능한가를 알아보고 빙햄유체모델로 설계 된 ER댐퍼의 모델과 비교하였다. ER배르와 ER댐퍼의 수학적 모델을 시뮬레이션한 결과는 약간 벗어남이 보이기는 하나 실험결과와 일치하요 있다. 이것은 ER유체를 단순히 빙행유 체로 취급할수없으나 거시적으로는 빙햄유체로 취급할수 있음을 시사한다.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

A Study on Low Noise Cooling/Ventilation System for Large Electric Motor (대형 전동기 냉각/통풍 시스템의 저소음화 연구)

  • Jo, Hye-Young;Jang, Ji-Sung;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.973-974
    • /
    • 2014
  • 대형 전동기의 주요 소음원은 전자기 소음과 냉각/통풍 시스템 소음이며, 이 중 냉각/통풍 시스템이 전체 소음에 큰 영향을 미친다. 본 논문에서는 대형 전동기의 저소음 냉각/통풍 시스템 개발을 위해 저소음 냉각 팬을 개발하고 팬 커버 내부의 유로를 개선하였다. 유동해석은 상용 CFD 소프트웨어를 이용하였으며 팬 커버 내의 scroll 형상 및 air guide, baffle 의 유무에 따라 팬 커버의 압력손실을 계산하였다. 해석을 통해 팬 커버 내부의 난류 유동과 압력손실이 가장 작은 팬 커버 형상을 도출하였으며 개선된 냉각/통풍 시스템이 기존 냉각/통풍 시스템보다 6.5dB 감소된 것을 확인하였다.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Optimization of supersonic ejector (2차 노즐목을 갖는 초음속 이젝터의 최적화)

  • Park, Hyung-Ju;Yoon, Shi-Kyung;Yeom, Hyo-Won;Sung, Hon-Gye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.130-134
    • /
    • 2010
  • The effects of design parameters of supersonic ejector system under the assumption of constant pressure mixing were performed. Design parameters were mass flow rate ratio, area ratio between primary and secondary flow, and primary Mach number. 1-D theoretical performance of ejector in terms of pressure ratio and contraction ratio with and without loss mechanism such as diffuser efficiency and friction were considered.

  • PDF

Numerical Analysis of Fluid Flow in a Regenerative Cooling Passage (재생냉각 유로 내의 유동에 관한 수치해석)

  • 조원국
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2000
  • A computational analysis has been made on fluid flow in a regenerative cooling Passage for a reduced size liquid rocket engine to predict pressure drop and heat transfer rate in it. The contraction/expansion of the cross sectional area of the passage turn out to increases both the pressure loss and the heat transfer rate of the duct. The changes of the cross sectional area near the nozzle throat are effective to protect the throat which suffers from severe thermal load. Also given is the qualitative characteristics of the performance of the regenerative cooling system due to the variation of coolant flow rate.

  • PDF

슬롯 각도에 따른 경계층 상호작용의 피동제어 성능 및 유동 구조 비교 연구

  • Lee, Hun-Sik;Lee, Jae-Hwan;Kim, Jong-In
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.96-100
    • /
    • 2016
  • 슬롯판을 이용한 경사충격파와 경계층 간섭유동 제어에서, 슬롯의 각도를 바꾸어 가며 제어 성능을 비교하는 수치적 연구가 수행되었다. 기준이 되는 수직 슬롯, 각도를 달리한 6개의 case를 선정하여 하여 충격파 뒤에서 전압손실 및 경계층 안정성을 기준으로 제어 성능을 평가하였다. 수치해석 결과 모든 형상에 대해 제어하지 않은 상태보다 좋은 성능을 얻었다. 공력성능이 뛰어난 그룹과 그렇지 않은 그룹을 구분하여 슬롯과 공동 유동 구조를 분석하면서 경계층 불안정성을 야기하고 전압손실 감소에 영향을 미치는 것은 경계층과 충격파가 상호작용하는 영역에서 Vortex를 얼마나 제어할 수 있는지 여부임을 알 수 있었고, 이러한 Vortex를 얼마나 제어할 수 있는지에 따라 공력 성능이 결정됨을 파악할 수 있었다.

  • PDF

A Numerical Study of the Three-Dimensional Convective Heat Transfer in an Infant Incubator (신생아 보육기 내에서의 삼차원 대류 열전달에 관한 수치해석)

  • 전성수;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.35-40
    • /
    • 2001
  • 압력기반의 유한체적법과 k-$\varepsilon$난류모델을 이용하여 신생아 보육기 내의 삼차원 정상난류유동해석과 대류현상에 의한 열전달을 해석하였다. 보육기 내의 주된 공기유동은 입구에서 유입된 공기가 보육기 위쪽을 지나 출구로 이동하며 각진 구석에서 작은 와류들이 관찰되었다. 보육기의 입구부를 제외한 대부분에서의 유속은 0.1m/s 이하로 나타났으며, 신생아의 다리부분에서의 속도가 머리부분보다 다소 크게 관찰되었다. 입구쪽의 온도가 출구쪽의 온도보다 1~2$^{\circ}C$ 높게 나타났으며 속도 크기가 큰 다리부분에서의 온도가 머리 또는 목부분보다 다소 낮았다. 보육기 내의 온도변화는 약3~4$^{\circ}C$로 다소 크게 나타났는데 이는 입구에서 유입된 공기가 상벽과 직각으로 만나며, 보육기 외벽의 각진 구석부분에 의한 영향으로 생각된다. 따라서 입구속도를 적절히 줄이거나 유선형의 유동을 갖도록 설계하여 열손실을 최소화한다면 보다 효율적인 보육기가 될 것으로 생각된다.

  • PDF