• Title/Summary/Keyword: 유도지진

Search Result 253, Processing Time 0.021 seconds

An Evolution of Nonlinear Dynamic Response of an Unreinforced Masonry Structure (비보강 조적조의 비선형 동적 거동의 전개)

  • Kim, Nam-Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.77-84
    • /
    • 2006
  • Unlike homogeneous material structure, the behavior of masonry structure is not perfectly elastic even in the range of small deformations because it is a non-homogeneous and anisotropic composite structural material, consisting of masonry units, mortar, and grout. This paper proposes a simplified way of investigating the evolution of the deformation and damage of the structure subjected to a series of successive ground motions with varying shaking. Especially, the most simple but useful algorithm of Fast Fourier Transformation (FFT) has been adopted to investigate the evolution of the deformation and damage of the structure tested on the shaking table. Moreover, the development of a hi-linear curve for an equivalent SDOF system which is obtained by exploiting the frequency and stiffness relationship was discussed. Finally, some important findings related to inelastic properties of the URM are summarized.

Modified Dispersion-Correction Scheme on Variable Depth for Simulating Tsunami Propagation (수심변화를 고려한 지진해일 전파 모의 수정기법)

  • Ha, Tae-Min;Kim, Joo-Young;Lee, Jong-Kyu;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • 본 연구에서는 수심이 변화하는 지형에서 지진해일 전파를 수치모의하기 위해 기존의 분산보정기법을 개선하였다. 이를 위해 바닥경사를 고려한 지배방정식을 유도하고 기존의 분산보정기법에 새로운 항을 도입하여 수정기법을 제안하고 적용성을 검토해보았다. 수치모의 결과 새로운 수정기법이 기존의 분산보정기법에 비해 수심이 변화하는 지형에서 분산을 좀 더 정확하게 고려할 수 있는 것으로 나타났다.

  • PDF

Statistical Study of Ductility Factors for Elastic Perfectly Plastic SDOF Systems (탄소성 단자유도 구조물에 대한 연성계수의 통계적 분석)

  • Kang, Cheol-Kyu;Choi, Byong-Jeong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.39-48
    • /
    • 2003
  • This paper present a summary of the results of statistical study of the ductility factor which is key component of response modification factor(R). To compute the ductility factor, a group of 1,860 ground motions recorded from various earthquake was considered. Based on the local site conditions at the recording station, ground motions were classified into four groups according to average shear wave velocity. Inleastic spectrum were computed for elastic perfectly plastic SDOF systems undergoing different level of inelastic deformation and period. Ductility factors were calculated by deviding elastic response spectrum by inelastic response spectrum. The influence f displacement ductility ratio, site condition, magnitude and epicentral distance on ductility factors were studied. The coefficient of variation was computed to evaluated the dispersion of ductility factors as the defined ratio of the standard deviation to the mean.

Development of New Probabilistic Seismic Hazard Analysis and Seismic Coefficients of Korea Part II: Derivation of Probabilistic Site Coefficients (신(新) 확률론적 지진분석 및 지진계수 개발 Part II: 확률론적 지진계수 도출)

  • Kwak, Dong-Yeop;Jeong, Chang-Gyun;Lee, Hyunwoo;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.111-115
    • /
    • 2009
  • In Korea, the probabilistically developed seismic hazard maps are used with deterministically derived seismic site coefficients in developing the design response spectrum of a specific site. Even though the seismic hazard maps and seismic site coefficients are incompatible, the current design code ignores such incompatibility. If the seismic hazard map and seismic coefficients are both developed in identical probabilistic framework, such problems can be solved. Unfortunately, the available method cannot be use to derive "true" probabilistic site coefficients. This study uses the ground motion time histories, which were developed as the result of a new probabilistic seismic hazard analysis in the companion paper, as input motions in performing one-dimensional equivalent linear site response analyses, from which the uniform hazard response spectra are generated. Another important characteristic of the hazard response spectra are that the uncertainties and randomness of the ground properties are accounted for. The uniform hazard spectra are then used to derive probabilistic site coefficients. Comparison of probabilistic and deterministically site coefficients demonstrate that there is a distinct discrepancy between two coefficients.

  • PDF

Design of Friction Dampers installed at a Multi-Story Building under Seismic Load (지진하중을 받는 다층 건물에 설치된 마찰감쇠기 설계)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.457-462
    • /
    • 2011
  • In this study, a simplified design procedure for friction dampers of a multi-story structure in order to reduce seismic response is proposed. To get insight for control effect of the structure with friction dampers is difficult, because of a nonlinear characteristic by a friction damper. Since a control force of a friction damper is influenced by coupling velocity between floors, adjoining modes are coupled. Thus structural response are derived by assuming steady-state response in resonance. As it is impossible that an exact solution is obtained for seismic load, first, a closed form solution can be achieved under harmonic vibration. Second, to convert a three-story building into a single-degree-of-freedom(SDOF) structure, modal analysis is performed. Third, an equivalent damping ratio is derived with utilizing closed form solution. And response reducing factor is proposed by it. Finally, friction force of a damper is designed for using response reducing factor, and then designed dampers are verified for seven seismic data. The nonlinear analysis results confirm the validity of the proposed procedure.

Estimation of the First Modal Participation Factor of a Shear Building under Earthquake Load (지진하중을 받는 전단구조물의 1차 모드참여계수 산정)

  • Hwang, Jae-Seung;Kim, Hong-Jin;Kang, Kyung-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.25-32
    • /
    • 2005
  • Seismic load is distributed to modes of a structure through the modal participation factor(MPF). The modal participation factor is essential to analyze structural response under earthquake load. MPF of a real structure differs from that of analytical mathematical model due to the error induced from analytical assumptions and during the construction. In this study, an identification method is proposed to calculate the 1st MPF of real structure based on $H^{\infty}$ optimal model reduction. The MPF is obtained from the relationship between observability and controllability matrices realized from system identification and those of a prototype 2-degree state space model. The proposed method is verified thorough numerical examples.

GIS-based Loss Estimation and Post-earthquake Assessment of Building Damage (빌딩피해에 대한 GIS 손상평가 및 지진 후 평가)

  • Jeon Sang-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.15-24
    • /
    • 2004
  • This paper describes a GIS-based assessment of residential building damage caused by the 1994 Northridge earthquake in which the fractions of existing buildings damaged at various percentages of replacement cost are related to a range of seismic parameters. The assessment uses data from safety inspection reports and tax assessor records, both of which were geocoded and linked to seismic parameters derived from strong motion records at 164 different sites. The paper also describes a GIS-based pattern recognition algorithm for identifying locations of most intense building damage. The algorithm provides a framework for rapidly screening remote sensing data and dispatching emerging services.

Seismic Fragility Analysis of Lightning Arrester using Capacity Spectrum Method (역량스펙트럼 방법을 이용한 피뢰기의 지진취약도 해석)

  • Kim, Gwang-Jeon;Song, Jong-Keol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.255-263
    • /
    • 2014
  • In this paper, seismic fragility analysis of lightning arrester is performed using capacity spectrum method(CSM). Since seismic fragility analysis of structure with many structural members is required to calculate many inelastic responses for several tens or hundreds of ground motions, simple method such as CSM is more appropriate than response history analysis(RHA). In general, accuracy of seismic response evaluated by CSM is less than that by RHA. In order to increase accuracy of CSM, equivalent SDOF method and performance point calculation technique are applied to CSM. Seismic fragility method proposed by Shinozuka et al. is used. In order to evaluate site effect of ground motions on seismic fragility, 60 different site classification earthquakes are selected as input ground motions. From the seismic fragility curves of lightning arrester evaluated by CSM and RHA, it can be observed that the seismic fragility curves evaluated by CSM are very similar to those by RHA. Also, it can be observed that main seismic failure mode of lightning arrest is bushing breakage.