• Title/Summary/Keyword: 유도성 통신 연결 장치

Search Result 10, Processing Time 0.033 seconds

Development of Communication Joint Tools for Implementing a Legacy-line Communication System in a Train (열차 내 무배선통신시스템 구축을 위한 통신연결장치 개발)

  • Kim, Hyun Sik;Park, Soo Hoon;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.877-887
    • /
    • 2015
  • In this paper, a design of communication joint tools to implement a legacy-line communication (LLC) system, which exploits various conductive lines in a train, is presented. We develop two kinds of joint tools; one is a conductive joint tool (CJT) that is connected directly to the conventional lines and the other is the inductive joint tool (IJT) which connects the conventional lines indirectly using electromagnetic induction. As a result, the practical experiment of data communication confirms that an LLC system with the developed joint tools has a transmission rate more than 20 Mbps in the distance of 200 m away. In addition, an environmental durability test shows that the joint tools operate stably in an extreme environmenal variation. It is, therefore, considered that the developed joint tools are very useful to implement a communication network in the train working currently.

A Fire Prevention System of the Nacelle of Wind Turbine Generator System Based on Broadband Powerline Communication (광대역 전력선통신 기반 풍력발전기 너셀 내부 화재예방시스템)

  • Kim, Hyun-Sik;Ju, Woo-Jin;Kang, Seog Geun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1229-1234
    • /
    • 2018
  • In this paper, a fire prevention system based on a broadband powerline communication (PLC) system is implemented and a demonstration experiment is carried out to prevent from or promptly dealing with possible fires within the nacelle of a wind turbine generator system (WTGS). For this purpose, an inductive coupler having satisfactory attenuation characteristic in the frequency region for high-speed PLC is also manufactured. It is confirmed that the implemented system can monitor the environmental change inside the nacelle in real time by transmitting various information obtained by the sensors such as temperature, flame, and smoke sensor installed in the nacelle and thermal image recorded by a thermal camera to the ground control center through the PLC system. Therefore, it is, considered that the implemented system will significantly improve the reliability of the fire monitoring and prevention system of the WTGS in conjunction with the existing safety system.

Vulnerability Case Analysis of the High Power Electromagnetic Pulse on Digital Control System (디지털 제어장치의 고출력 전자기펄스에 대한 취약성 사례 분석)

  • Woo, Jeong Min;Ju, Mun-No;Lee, Hong-Sik;Kang, Sung-Man;Choi, Seung-Kyu;Lee, Jae-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.698-706
    • /
    • 2017
  • The risk of high power electromagnetic(HPEM) pulse exposure to the devices used in digital control system such as PLC(programmable logic controller) and communication cable is increasing. In this paper, two different frequency ranges HPEMs were exposed to those control systems to assess the each vulnerability. The vulnerability of the EUTs exposed from HPEM were analyzed and compared with a variation of distances and source power. As the EUTs were exposed to higher level of HPEM, the voltage and communication waveform of the control system had shown a distorted response. And the unshielded twisted pair(UTP) cable connected to the EUTs showed operation failures with induced voltage. However, the foiled twisted pair(FTP) cable shielded the connected device efficiently from the HPEM exposure. Therefore, the necessity of the protection measures against the vulnerability of HPEM exposure for the digital control system used in power facilities and industrial site were verified.

A Powerline-based Legacy-line Communication System for Implementation of a Communication Network in Ship (선박 내 통신네트워크 구축을 위한 전력선 기반 무배선통신시스템)

  • Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1831-1838
    • /
    • 2015
  • In this paper, a method of implementing a communication network in ship, which exploits a powerline-based legacy-line communication system (LLC), is presented. We develop an inductive coupling unit and a multi-interface device to connect a data communication terminal to the powerline. As a result of operation tests for the ship under working, the implemented LLC shows a transmission rate of at least 25.8 Mbps in the distance of 200 m away with 100% success rate. Thus, the system can be a useful alternative to implement a communication network in ship without additional channels. Being easy to be implemented and supporting various interfaces for data communication, the presented system will be very effective when a real-time monitoring system is launched in future digital ship.

Performance analysis of legacy line communication using high current powerlines in midrange wind turbines (중형급 풍력 발전기내 전력선을 이용한 무배선 통신 성능분석)

  • Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.336-341
    • /
    • 2016
  • This paper presents an implementation of a communication network in wind turbines, which exploits the power-line communication system (PLC). We used an inductive coupling unit and a multi-interface device to connect a data-communication terminal to the power line, to ensure that stable communication was possible at various electric current and voltage values of the generator. The results of the operation tests conducted on an operational wind turbine showed that the implemented PLC demonstrated a transmission rate of at least 43 Mbps with a 100% success rate. Moreover, a real-time image was transmitted. Thus, the system could be a useful alternative for implementing a communication network in wind turbines that does not require additional channels. Since the presented system is easy to implement, and can support various interfaces for data communication, it will be quite useful when a real-time monitoring system is launched in wind turbines.

Design of Semiconductor-Operated Bidirectional Transformers Driven by Polarities of Alternating Voltage Sources (교류 전압원의 극성에 따라 구동하는 양방향 반도체 변압기의 설계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.253-259
    • /
    • 2015
  • In this paper, we propose a transformer of alternating voltage source utilizing a semiconductor, operating in bidirectional fashion. Transformer is a device transferring energy by inductive coupling between its winding circuits. Conventional transformer is a device, composed of a primary coil and a secondary coil, transforming an alternating voltage. The system we propose is designed with a single circuit transforming the level of voltage signal in two ways; from the source to the load, and vice versa. For semiconductor switches, the NPN transistor is connected to the alternating voltage source terminal, and emitter terminal is connected to the inductor in the system as an energy storage element. The control signal is applied to the base terminal of the semiconductors. We have shown that the system we propose, by adopting only one circuit, drives an alternating voltage transformer that changes the amplitudes of voltage signal in reciprocal way.

Design on the interfacing between auto-pilot and water-jet drive system (Auto pilot 와 water jet drive system 간의 Interface 설계)

  • Jin, Hyong-Du;Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.535-538
    • /
    • 2009
  • Auto Pilot is the system which move automatically the vessel through locating operation mode to automatic after entering operating course using a electronic chart or plotter. And water jet is the a propulsion system that make a power to push the vessel through spouting the accelerated water which is absolbed by the hole in the bottom of vessel. The water jet receive the effect of the depth of water lowly, it's acceletion efficiency is higher under high speed and have an advantage on vibrating and floating sound, so it's demand is increasing as new propulsion system. However, the signal systems of auto Pilot and water jet are defferant, we need the system to communicate between each system. We propose the interface system which communicate between Auto pilot and water jet efficiently in this journal.

  • PDF

Tele-Present Guitarist based on a Tangible Glove and a Smartphone (Tangible Glove 및 Smartphone 기반 Tele-Present Guitarist)

  • Kim, Hyung-Suk;Lee, Kang-Hee
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.23-25
    • /
    • 2012
  • 본 논문에서는 smartphone과 Arduino, Max/Msp를 이용한 모바일 미디어 아트 시스템을 제안한다. 시스템의 입력장치로 flexible센서가 부착된 tangible glove와 smartphone의 app이 사용되었고 이들의 조작 데이터는유(무)선 시리얼통신 및 TCP/IP 통신을 통해 원격지 서버상의 Max/Msp 어플리케이션으로 전달된다. 서버는 전달된 데이터를 기반으로 서버와 연결되어 있는 로봇 기타리스트의 열손가락을 제어하고 사운드 및 제반 영상을 출력한다. 결과적으로 사용자는 연주자인 동시에 관객으로서 시각, 촉각, 청각의 다양한 감각을 동시에 만족하고, 시스템에 몰입할 수 있게 된다. 본 논문에서는 기존 미디어 아트 시스템들이 가지고 있었던 사용자의 단순 참여라는 1차원적인 논리에서 벗어나고자 다양한 시스템의 결합을 통해 작품참여를 유도하였고 이를 통해 사용자가 그들만의 고유한 작품을 생성함으로써 기존의 미디어 아트 시스템과의 차별성을 도모하였다.

  • PDF

Analysis of advancement model of 1st generation dairy smart farm based on Open API application (개방형 제어기반 1세대 낙농 스마트팜의 고도화 모델 적용 분석)

  • Yang, Kayoung;Kwon, Kyeong-Seok;Kim, Jung Kon;Kim, Jong Bok;Jang, Dong Hwa;Ko, miae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.180-186
    • /
    • 2020
  • ICT convergence using smart livestock is that in the first-generation dairy smart farm model, each device made by several manufacturers uses its own communication method, limiting the mutual operation of each device. This study uses a model based on open control technology to secure interoperability of existing ICT devices and to manage data efficiently. The open integrated control derived from this process is the software interface structure of Open API. It is an observer that serves as real-time data collection according to the communication method of ICT devices and sensors located at each end. It consists of a broker that connects and transmits to the upper integrated management server. As a result of the performance analysis through verification of two first-generation dairy smart farm model sites, the average daily milk production increased compared to the previous year (farm A 5.13%, farm B 1.33%, p<0.05). Cow days open (DO) was reduced by 17.5% on farm A and 13.3% for farm B(p<0.05). Cows require an adaptation period after the introduction of the ICT device, but if continuous effects are observed, the effect of production can be expected to increase gradually.

A Study on Optical Current Sensor and Voltage Sensor for automation of power distribution (배전자동화 개폐기 내장형 광 전류 및 광 전압 센서에 관한 연구)

  • 양승국;오상기;박해수;김인수;김요희;홍창희
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.89-98
    • /
    • 2002
  • Optical current sensor and optical voltage sensor modules were designed and fabricated to improve measurement error and insulation in automatic power distributor By using Faraday effect, optical current sensor with an $\alpha$-iron core was designed and fabricated to minimize current induction of the other phase and was optimized to maintain linearity. Optical voltage sensor was fabricated owing to the pockets effect and adopted spatial electric field type because of small room in an automatic power distributor. To connect a distributor with an external terminal for signal processing, optical multi connector was designed, fabricated and tested for coupling loss and gas leakage. The linearity of optical current sensor for applied current maintains variation of smaller than 2.5% for applied current range from 20A to 700A. The linearity of optical voltage sensor was smaller than 1% for appling voltage from 6.6kV to 19.8kV. Since the measured characteristics are good, these devices can be considered as being applicable in practice.