• Title/Summary/Keyword: 위험물 규정

Search Result 91, Processing Time 0.029 seconds

Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall system (기존 철근콘크리트 벽식 공동주택의 내진 성능 예비 평가법에 관한 연구)

  • Chung, Lan;Woo, Sung-Sik;Choi, Ki-Young;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.293-300
    • /
    • 2007
  • In Korea, the seismic design regulations was established since 1988 about regularity scale of structures. However, It was not established about seismic performance and evaluation method as the most existing buildings was constructed before Earthquake-Resistant Design(1988). In this study, for model structures which are 4 units of non-seismic designed apartment and 3 units of seismic designed in Korea performed seismic performance evaluation by suggested KISTC (2004). And the result compare to evaluate Capacity Spectrum Method by using MIDAS Gen and SDS. As a result, we observed that suggested KISTC's method have overestimated for shear stress and drift index. The purpose of this study provides most conformity seismic performance evaluation process and the appropriate method of calculating the seismic performance index in Korea.

A Neural Network-Based Tracking Method for the Estimation of Hazardous Gas Release Rate Using Sensor Network Data (센서네트워크 데이터를 이용하여 독성물질 누출속도를 예측하기 위한 신경망 기반의 역추적방법 연구)

  • So, Won;Shin, Dong-Il;Lee, Chang-Jun;Han, Chong-Hun;Yoon, En-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.38-41
    • /
    • 2008
  • In this research, we propose a new method for tracking the release rate using the concentration data obtained from the sensor. We used a sensor network that has already been set surrounding the area where hazardous gas releases can occur. From the real-time sensor data, we detected and analyzed releases of harmful materials and their concentrations. Based on the results, the release rate is estimated using the neural network. This model consists of 14 input variables (sensor data, material properties, process information, meteorological conditions) and one output (release rate). The dispersion model then performs the simulation of the expected dispersion consequence by combining the sensor data, GIS data and the diagnostic result of the source term. The result of this study will improve the safety-concerns of residents living next to storage facilities containing hazardous materials by providing the enhanced emergency response plan and monitoring system for toxic gas releases.

  • PDF

Improvement for BF (Barrier Free) Certification to Ensure Disaster Safety for the People with Disabilities (장애인 재난 안전확보를 위한 BF(Barrier Free) 인증제도의 개선 방향)

  • 박진용
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.230-233
    • /
    • 2023
  • 우리 헌법은 인간의 존엄과 가치 그리고 행복을 추구할 권리를 보장하고 있으며, 편의증진법과 교통약자법을 통해 장애인등이 교통수단, 여객시설 및 도로 등을 비장애인들과 차별 없이 이용하여 이동하고, 도로와 대중교통수단, 공공 건축물과 주거 등 생활 필수시설에 자유롭게 접근하기 위한 접근권을 보장하고 있다. 우리나라는 이동권의 보장을 편의시설 제도라는 독자적인 체계를 통해 이루어지고 있으며, 이를 실질적으로 보장하기 위하여 장애물 없는 환경 인증 제도(BF 인증제도)를 도입하였다. 시행 15년을 맞은 BF 인증제도는 양적으로는 많은 발전을 가져왔지만, 질적으로 특정 건축물 등 일부에 대한 인증 편중 현상이 있으며 안전취약계층에 대한 재해 안전확보에 대한 고려가 포함되지 않아 부진정한 이동성과 접근성의 보장이라는 한계를 가지고 있다. 이동권 보장이 얼마나 잘 이루어지느냐는 그 나라의 사회 안전망이 얼마나 잘 갖추어져 있는지 판단하는 척도라 할 것이며, 따라서 이러한 이동권 보장은 위험상태에서의 안전한 피난을 함축하고 있으며 중첩적으로 국가의 기본권 보호 의무의 이행과 관련된다. 이에 따라 이동권과 접근권의 증진을 위한 BF 인증 규정을 안전 규범으로 보완하여 장애인과 비장애인이 사회의 일원으로서 평등한 인격적 주체로 공동체에 기여하는 안전한 사회적 환경의 조성이 긴절히 요청된다고 할 수 있다.

  • PDF

A Research of Grain Size Analysis of Particulate Matter in Fire Effluent (연소 생성물 내 입자상 물질의 입도에 관한 연구)

  • Kim, Sung-Soo;Choi, Seo-Yeon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.8-12
    • /
    • 2014
  • Interior finishing materials using noncombustible were regulated by the building codes to prevent the spread of fire and protect occupants. The average deed of stopping time of experimental mouse exposing combustion gas were measured by KS F 2271 gas toxicity test. At that time, The average deed of stopping time under 9 minutes were judged a inconsistence. This experiment method has limit to find out a cause of toxicity effect factor. In this study, particle size analysis were performed for investigate a major factor.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Study on Exposed Piping with High Risk of Fire (화재 위험성이 높은 노출배관 사용에 관한 연구)

  • Kim, Yeob-Rae;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.61-66
    • /
    • 2015
  • PVC pipe has excellent corrosion resistance and chemical resistance and is broadly used. However there are no regulations regarding exposed piping material in buildings. There is growing concern about the vulnerability of piping to fires and generating toxic gas. Exposed piping should be made of incombustible materials to prevent spreading of toxic gas and to minimize damage to life and property in case of fire. Many big structures are being built, and concerns regarding damage by fire are continuously growing. In these circumstances, we should reinforce fire safety standards for buildings and heighten safety consciousness to become a well-developed country. For these reasons, we investigated the materials used for exposed piping and the standards of well-developed countries to enhance safety. We tried to figure out the alternatives by examining the actual conditions of each region's buildings. Based on the use of incombustible materials for exposed piping in each region, we tried to enhance the effectiveness for safety by suggesting revisions for related laws and regulations.

Development of a Systemized Flying Net for Safety Improvement in Architectural Building Construction (건설 공사의 안전성 향상을 위한 충돌방지형 시스템 플라잉넷의 개발)

  • Lee, Jeong-Ho;Park, Seon-Joo;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.5
    • /
    • pp.71-80
    • /
    • 2011
  • Flying net should be installed on every 3 or 4 construction floor from 8m above ground according to the rule. In the apartment housing construction, flying net installation work has been recognized the most dangerous work among the whole works because a small mistake of labors might make their death accident. Sub-contractors specialized in flying net have been developing various flying net types. However, most works of installing flying net as working with the developed system are performed outside the apartment housing, so that the risk of fall in works of installing supports and unfolding net is still high. Furthermore, as using the previously developed flying net labors might bump into the frame or the wire rope for supporting so that it makes secondary accidents. The objective of this research is to produce the proto-type of anti-collision flying net system based on the result of problem analysis on the installation and detachment process and suggest the improved anti-collision flying net system, which is able to improve safety and field applicability by conducting field experiment and analyzing performance.

Development of Climate Change Adaptation Plan for Kurunegala City, Sri Lanka (스리랑카 Kurunegala시의 기후변화 적응 계획 개발)

  • Reyes, Nash Jett DG.;Cho, Hanna;Geronimo, Franz Kevin F.;Jeon, Minsu;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.354-364
    • /
    • 2019
  • Sri Lanka is an island nation susceptible to climate-related disasters and extreme weather events. Kurunegala City is the developing capital city of the North-Western Province of Sri Lanka. Changes in rainfall patterns and a steadily increasing annual average temperature amounting to 0.69±0.37℃ were observed in the city area. Generally, urban areas are at risk due to the lack of climate change adaptation provisions incorporated in the development plans. This study was conducted to investigate the characteristics of Krunegala City, Sri Lanka and develop an appropriate climate change adaptation plan for the city. Site investigation and qualitative risk assessment were conducted to devise a plan relevant to the climate change adaptation needs of the city. Qualitative risk analyses revealed that drinking water, water resources, and health and infrastructure risks were among the major concerns in Kurunegala City. Low impact development (LID) technologies were found to be applicable to induce non-point source pollutant reduction, relieve urban heat island phenomenon, and promote sound water circulation systems. These technologies can be effective means of alleviating water shortage and reducing urban temperature. The measures and strategies presented in this study can serve as reference for developing climate change adaptation plans in areas experiencing similar adverse effects of climate change.

Experimental Study on the Flash Over Delay Effects according to the Prevention of Flame Spread between Composite Material Panels (복합자재의 패널 간 화염확산방지에 따른 플래시오버 지연 효과에 대한 실험적 연구)

  • Kim, Do-hyun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • A sandwich panel is a composite material composed of a double-sided noncombustible material and insulation core which is used in the inner, outer walls, and roof structure of a building. Despite its excellent insulation performance, light weight and excellent constructability, a flame is brought into the inside of the panel through the joint between the panels, melting the core easily and causing casualties and property damage due to the rapid spread of flame. The current Building Law provides that the combustion performance of finishing materials for buildings should be determined using a fire test on a small amount of specimen and only a product that passes the stipulated performance standard should be used. This law also provides that in the case of finishing materials used for the outer walls of buildings, only materials that secured noncombustible or quasi-noncombustible performance should be used or flame spread prevention (FSP) should be installed. The purpose of this study was to confirm the difference between the dangers of horizontal and vertical fire spread by applying FSP, which is applied to finishing materials used for the outer walls of buildings limitedly to a sandwich panel building. Therefore, the combustion behavior and effects on the sandwich panel according to the application of FSP were measured through the construction to block the spread of flame between the panels using a full scale fire according to the test method specified in ISO 13784-1 and a metallic structure. The construction of FSP on the joint between the panels delayed the spread of flame inside the panels and the flash over time was also delayed, indicating that it could become an important factor for securing the fire safety of a building constructed using complex materials.

Monitoring Country-of-Origin Labels and Indication Contents for Meat on Electronic On-line Trading (전자상거래의 축산물 원산지 표시실태 및 표시규정 모니터링)

  • Nam, Jung-Oak;Nam, Bo-Ra;Park, Jung-Min;Lee, Ra-Mi;Gu, Hyo-Jung;Suh, Hyung-Joo;Chang, Un-Jae;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.27 no.1
    • /
    • pp.117-121
    • /
    • 2007
  • The number of internet users and the scale of electronic on-line trading are on the increase due to the development of information technology and the internet. The aim of this study was to monitor the accuracy of country-of-origin labels and the indicated contents of meat available by electronic on-line trading by using a structural interview sheet for 100 on-line meat product markets. The result of this investigation showed a 100% level of accuracy for business name and telephone number whereas the company address, meat manufacturer and supplier, and business registration were less reliable. We also investigated the accuracy of site policy, e-mail address, and fax number. The results showed that the accuracy of fax numbers was the lowest. The product name and the kind of meat actually in the product showed a 100% level of conformity, while the price (96.3%), place of origin (93.6%), capacity (90.4%), meat parts (80.9%) and contents of the product (73.4%) showed a relatively low level of conformity. Serious safety issues were exposed by the disturbingly low 20.2% accuracy of indicated expiration dates and 5.3% accuracy of indicated manufacturing dates. To ensure food safety, it is essential to improve consumer understanding and trust regarding food safety through continuous public relations. More education and information are needed to raise consumer awareness of the facts versus myths regarding food safety.