• Title/Summary/Keyword: 위치 편차

Search Result 605, Processing Time 0.027 seconds

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Submentovertex cephalometrics in korean adults (한국 성인에서 이하 두정 방사선 계측사진 분석)

  • Nahm, Dong-Seok;Suhr, Chung-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.1-7
    • /
    • 2000
  • It is important that the orthodontist accurately assess the degree to which facial asymmetry contributes to a given malocclusion before treatment planning. P-A, submentovertex and verticosubmental view have been used in the assessment of facial asymmetry. Among them, submentovertex view is rarely used because it has low reproducibility and is short of normal data and proper analysis method. The purpose of this study was to develop a submentovertex cephalomentrics and obtain normal data in Korean adults. The subjects consisted of 40 normal adults (male : 22, female 18) without the experience of orthodontic treatment. We find the 2 angular and 9 linear measurements. Though submentovertex cephalomentrics has the limitation in comparing the absolute length between right and left, it is useful to examine the relationship of skeletal and dental midline, the shape and location of condyle head and the shape of mandibular body in submentovertex view Therefore, if we understand the limitation of submentovertex cephalomentrics and use lateral , P-A and submentovertex cephalomentrics together, we will measure the location and amount of skeletal disharmony more exactly.

  • PDF

Analysis of 3D Accuracy According to Determination of Calibration Initial Value in Close-Range Digital Photogrammetry Using VLBI Antenna and Mobile Phone Camera (VLBI 안테나와 모바일폰 카메라를 활용한 근접수치사진측량의 캘리브레이션 초기값 결정에 따른 3차원 정확도 분석)

  • Kim, Hyuk Gi;Yun, Hong Sik;Cho, Jae Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • This study had been aimed to conduct the camera calibration on VLBI antenna in the Space Geodetic Observation Center of Sejong City with a low-cost digital camera, which embedded in a mobile phone to determine the three-dimension position coordinates of the VLBI antenna, based on stereo images. The initial values for the camera calibration have been obtained by utilizing the Direct Linear Transformation algorithm and the commercial digital photogrammetry system, PhotoModeler $Scanner^{(R)}$ ver. 6.0, respectively. The accuracy of camera calibration results was compared with that the camera calibration results, acquired by a bundle adjustment with nonlinear collinearity condition equation. Although two methods showed significant differences in the initial value, the final calibration demonstrated the consistent results whichever methods had been performed for obtaining the initial value. Furthermore, those three-dimensional coordinates of feature points of the VLBI antenna were respectively calculated using the camera calibration by the two methods to be compared with the reference coordinates obtained from a total station. In fact, both methods have resulted out a same standard deviation of $X=0.004{\pm}0.010m$, $Y=0.001{\pm}0.015m$, $Z=0.009{\pm}0.017m$, that of showing a high degree of accuracy in centimeters. From the result, we can conclude that a mobile phone camera opens up the way for a variety of image processing studies, such as 3D reconstruction from images captured.

A Study on the Inspection of Termite-damaged Wooden Buildings through the Use of Detection Dogs and an Analysis of Environmental Factors (탐지견 반응 및 환경 인자 분석을 통한 목조 건축물의 흰개미 피해 조사)

  • Kim, Young Hee;Lim, Bo A;Lee, Jeung Min;Jo, Chang Wook;Kim, Soo Ji;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.641-651
    • /
    • 2019
  • This study investigates three buildings arranged alongside at the same level, namely, the Josadang, the Buljojeon, and the Palsangjeon. Their backside is blocked by an embankment with an environmental condition unsuitable for wooden buildings. The pillar behind the Josadang had termite damage for which termite damage and environmental investigations had been conducted for the past four years. The termite damage was monitored four times using the termite detection dogs, and the environmental factors were surveyed 27 times, except during the winter season. As a result, the locations of the columns with a high frequency of responses from the termite detection dogs were found and damage was confirmed. According to the surface moisture content investigations, the surface moisture content was highest in the Josadang and lowest in the Buljojeon. After a statistical analysis, the mean, the median, and the mode values were compared. The difference between the mean and the median was found to be less, however, the mode varied significantly. The mode values of the Josadang and the Palsangjeon were 14.5% and 10.8%, respectively, higher than the 6.1% mode value of the Buljojeon. It was concluded that the temperature and the water content affected the termite damage, which increases if the temperature and the water content remain constant owing to the environmental factors.

Analytical Evaluation of Behavior of Precast PSC Box Curve Bridge Based on Design Variables (프리캐스트 PSC 중공 박스 곡선교의 설계변수에 관한 해석적 거동 평가)

  • Kim, Sung-Bae;Kim, Sung-Jae;Park, Jeong-Cheon;Uhm, Ki-Ha;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.267-275
    • /
    • 2014
  • Recently, the construction of curved bridge has increased, thus researchers perform the analytic studies on PSC curved bridge. However, the grid analysis method that are mostly used in the construction industry is not adequate to acquire the precise behavior evaluation of curved PSC briges. Therefore, the precise finite element analysis considering the effective variables were performed to establish the basis for the design method of curved PSC bridge by using 3D elements and bar element. The evaluated variables in this analysis were the number of girders, loading point, section figure, change of prestressing force. The results show the load carrying capacity of the 3 girder type bridge is 200% of that of the 2 girder type, and that applying load on outer girder makes the load resistance capacity and the deflection deviation of 2 girders smaller. The structural capacity of the bridge is improved when the section size is increased, but the efficiency of it is not sufficient enough compare to that of the change of prestressing forces. The change of prestressing forces shows that the camber and the load carrying capacity are linearly increased as PS force is increased. Moreover, when the PS force applied on outer girder is increased than that of inner girder, the deviation of deflection the girders decreases, thereby the stability of the bridge is enhanced.

A Study on Magnetoresistance Uniformity of NiFE/CoFe/AlO/CoFe/Ta TMR Devices Prepared by ICP Sputtering (ICP 스퍼터를 이용한 NiFe/CoFe/AlO/CoFe/Ta TMR 소자 제작에 있어서의 자기저항 균일성 연구)

  • 이영민;송오성
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.189-195
    • /
    • 2001
  • We prepared TMR junctions of NiFe(170 )/CoFe(48 )/Al(13 )-O/CoFe(500 )/Ta(50 ) structure on 2.5$\times$2.5 $\textrm{cm}^2$ area Si/SiO$_2$ substrates in order to investigate the uniformity of magnetoresistance(MR) value using a ICP magnetron sputter. Each layer was deposited by the ICP magnetron sputter and tunnel barrier was formed by the plasma oxidation method. We measured MR ratio and resistance of TMR devices with four-terminal probe system by applying external magnetic field. Although we used ICP sputter which is known as superior to make uniform films, the standard variation of MR ratio was 2.72. The variation was not dependent on the TMR devices location of a substrate. We found that MR ratio and spin-flip field (H's) increased as the resistance increased, which may be caused by local interface irregularity of the insulating layer. The variation of resistance value was 64.19 and MR ratio was 2.72, respectively. Our results imply that to improve the insulating layer fabrication process including annealing process to lessen interface modulation in order to mass produce the TMR devices.

  • PDF

Hydrological survey and analysis considering field conditions (현장여건을 고려한 수문조사 및 분석)

  • HwangBo, Jong-Gu;Yu, Young-moo;Jeong, Chan-Woong;Lee, Sang-Ho;Seo, Jeong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.265-265
    • /
    • 2022
  • 유량조사는 측선수, 측정시간, 측정위치, 측정방법 등 많은 기준이 있으며 이를 잘 준수하는 것이 높은 품질의 유량측정 성과를 확보하는 방법이다. 그러나 이러한 기본적인 기준을 잘 준수하더라도 현장 상황에 따라 유량측정 성과에 오차가 포함 될 수 있다. 본 연구에서는 상류 소수력발전소의 방류량에 따라 유량이 변화하고 수위관측소 부근에 큰 저류공간이 있는 현장 여건이 유량측정성과에 어떠한 영향을 끼치는지 검토하였다. 홍천군(주음치교) 관측소는 홍천강 상류에 위치하며 소수력발전소의 운영에 따라 관측소를 흘러가며 그 유량이 소수력발전소의 영향으로 점변한다. 일반적으로 이러한 경우 측정시간을 최대한 짧게 가져가 유량자료의 정확도를 확보한다. 하지만 홍천군(주음치교)의 경우 수위관측소 주변에 큰 저류공간이 있어 이를 동시에 고려해야 하며 단순하게 측정시간을 짧게 하는 것만으로는 측정성과의 품질을 확보 할 수 없다. 왜냐하면 이 저류 공간으로 물이 유입되는 시간동안은 수위관측소의 수위 상승은 미미하지만 하천 유량은 증가하는 부등류가 발생한다. 유량측정은 등류가정에 의한 것으로 수위관측소 주변이 부등류가 발생하면 유량측정 성과에 큰 오류가 나타나기도 한다. 홍천군(주음치교)에서 현장 상황이 등류일 때와 부등류일 때 모두 측정을 실시하였으며 그 차이를 확인하였다. 저류공간의 물 유입이나 유출이 없는, 즉 등류 상태의 유량측정 성과는 수위-유량관계식과 2.86%차이를 보였으며 부등류 상태의 유량측정 성과는 19.85%차이를 보여 큰 차이를 보였다(기준수위 0.49m). 또한 소수력발전소 운영에 따라 유량 상승 시에는 수위-유량관계곡선식 대비하야 양(+)의 편차율이 발생하고, 유량이 하강 시에는 수위-유량관곡선식 대비 음(-)의 편차율 발생하는 것으로 나타났다. 소수력 발전소는 동절기를 제외한 상시 운영으로 홍천군(주음치교) 관측소의 정확한 수위-유량관계식을 확인하기 위하여 소수력 발전소 운영을 중단하고 측정을 실시하였으며 유량변동을 멈추고, 즉 등류 흐름에서 측정한 성과는 수위-유량관계식과 차이가 1.06% 불과한 것으로 나타났다. 수문조사는 측선수, 측정시간, 측점수 등 많은 기준이 있다. 그러나 이러한 측정기준과는 별개로 현장은 다양한 조건이 발생하며 측정성과의 정확도에 영향을 끼치는 경우가 발생하기도 한다. 따라서 유량측정 기준을 잘 준수하는 것도 중요하지만 현장상황을 파악하고 이에 적절한 유량측정을 실시해야 그 오차를 최소화 할 수 있다.

  • PDF

Study on Direct Tensile Properties and Reliability Review of Steel Fiber Reinforced UHPC (강섬유 보강 UHPC의 직접인장 특성 및 신뢰성 검토에 관한 연구)

  • Park, Ji Woong;Lee, Gun Cheol;Koh, Kyung Taek;Ryu, Gum Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.125-132
    • /
    • 2018
  • In this study, a direct tensile test was planned to identify the tensile performance of UHPC, and the irregularity of cracks, which is a problem of the direct tensile test, was complemented through the introduction of notches at the center of a specimen. In this regard, a number of specimens divided by batch to reduce the deviation of direct tensile test values were fabricated to present reference data with respect to highly reliable direct tensile strength values. In addition, the mechanical properties and reliability of the specimens were examined under the curing conditions of the specified design strength of 120MPa for the steel fiber reinforced concrete with 1.5% fiber volume fraction, which is most suitable for the field application. As a result, the deviation of averages by batch between compressive strength and direct tensile strength did not show a large difference, and all cracks occurred within 20mm in the direct tensile test. At the 95% confidence interval of the direct tensile strength, the range was considerably small in the mean and the standard deviation, and there was no significant difference depending on the curing conditions. The results confirmed that a stable direct tensile test was performed, and highly reliable results were obtained through the fabrication of specimens by batch and test progress.

Optimum design of injection mold heater for uniform curing of LSR seal for waterproof connector (방수 커넥터용 LSR Seal의 균일 경화를 위한 사출 금형 히터의 최적 설계)

  • Song, Min-Jae;Cha, Baeg-Soon;Hong, Seok-Kwan;Ko, Young-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.310-315
    • /
    • 2017
  • Automotive waterproof connectors are highly functional parts that must be air-tight in a complex environment. In the LSR multi-cavity injection molding process for manufacturing waterproof connectors, it is important to maintain a uniform curing temperature between the cavities in order to obtain a quality product. For this purpose, we designed the capacity of the cartridge heater differently for each position, and then linked the heat transfer analysis and optimization module to obtain the optimal cartridge heater capacity. As a result of the optimization analysis, the temperature deviation between cavities was decreased from $13.1^{\circ}C$ to $8.1^{\circ}C$ compared with the case in which constant heater capacity was applied, so that the design criterion could be satisfied within a temperature deviation of $10^{\circ}C$ for uniform curing. This study suggests that this method can be applied efficiently to the design of a large area multi-cavity LSR mold heater.