• Title/Summary/Keyword: 위치표지자

Search Result 62, Processing Time 0.025 seconds

A Study on Operation Analysis and Improvement Method of Aids to Navigation AIS in Korean West Coast (서해권 항로표지용 AIS(AtoN AIS) 시스템의 운영실태분석 및 개선방안 연구)

  • Gug, Seung-Gi;Jeong, Tae-Gweon;Park, Hye-Ri;Kim, Jeong Rok
    • Journal of Navigation and Port Research
    • /
    • v.37 no.4
    • /
    • pp.391-400
    • /
    • 2013
  • Each country has recently established and operated so called Aids to Navigation(AtoN) AIS system collecting and transferring information on the sea state and AtoN's position. Korea has also decided to introduce the system and been establishing it. And it has already installed and operated this system in Incheon and Daesan. For the purpose of giving the national standards of AtoN AIS, this paper is to investigate the present states of AtoN AIS systems in the above two area and to suggest the improvement to the operation of AtoN AIS system. To make it, the paper deals with the international regulations of related AtoN AIS and the cases of foreign's AtoN AIS system installed and also investigates the operation states of the system, in five modules such as system management, system composition, information, function and cooperation. The followings are concluded; improving the inconsistency of system management, reducing operator's confusion caused by excessive display of AtoN AIS system, improving the problem of receiving unnecessary information, improving the functional problems caused by AIS communication inability and improving AtoN AIS information which is presently not used on board.

Study on Installation of Sector Lights for the Establishment of Safe Navigation Environment in Busan Port (부산항 안전항해환경 조성을 위한 지향등 설치방안 연구)

  • JEONG, Hae-Sang;LEE, Jong-Cheol;KIM, Jeong-Rok;GUG, Seung-Gi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.87-88
    • /
    • 2019
  • Leading Lights and Sector Lights provide a navigable channel, heading reference and a visual indication. Mariners can take easily a reference bearing or line of position. The Busan North Port needed to install a sector light to resolve blind sections because of Busan Port Redevelopment Project D-1 Block Construction Plan. And also the busan new port needed to install a sector light to give safety indication because navigation conditions will be changed due to removal of the to-island. For this reason, design development was made for installation of sector lights. In addition, the results of design development were compared with the AtoN simulation and verified. This paper is expected to be very useful for installing Sector Lights to guide the vessel to port safely in Korea.

  • PDF

Impact of Visual Performance on Recognition of Road and Traffic Sign (도로명판 및 교통표지판 인지에 미치는 시기능의 영향)

  • Chu, Byeong-Seon
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • The purpose of this study was to determine the legibility distance for traffic road sign and traffic sign, fixation duration and number of fixation during the time of recognition of traffic road signs under different vision conditions. This experiment was conducted on a closed-road circuit which has realistic driving road and environment Each participant drove the real vehicle for the experiment and specially built traffic road sign for the experiment and traffic road signs on the side of closed-road circuit were used. Different vision conditions were simulated using spectacle lenses to reach visual acuity 1.0 and 0.8 and it was 1.2 without spectacles and each participant tested under 3 vision conditions.. The result of this study demonstrated that there was a significant difference on legibility distance between visual acuity of 1.2 and 0.8 and there were also significant difference on fixation duration and number of fixations with smaller traffic signs. This study demonstrated the importance of vision correction for driving at night-time, also showed there would be difference on legibility distance and efficiency of eye movement such as fixation duration and number of fixation despite of satisfied visual acuity for driver's license requirement.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

Validation of QF-PCR for Rapid Prenatal Diagnosis of Common Chromosomal Aneuploidies in Korea

  • Han, Sung-Hee;Ryu, Jae-Song;An, Jeong-Wook;Park, Ok-Kyoung;Yoon, Hye-Ryoung;Yang, Young-Ho;Lee, Kyoung-Ryul
    • Journal of Genetic Medicine
    • /
    • v.7 no.1
    • /
    • pp.59-66
    • /
    • 2010
  • Purpose: Quantitative fluorescent polymerase chain reaction (QF-PCR) allows for the rapid prenatal diagnosis of common aneuploidies. The main advantages of this assay are its low cost, speed, and automation, allowing for large-scale application. However, despite these advantages, it is not a routine method for prenatal aneuploidy screening in Korea. Our objective in the present study was to validate the performance of QF-PCR using short tandem repeat (STR) markers in a Korean population as a means for rapid prenatal diagnosis. Material and Methods: A QF-PCR assay using an Elucigene kit (Gen-Probe, Abingdon, UK), containing 20 STR markers located on chromosomes 13, 18, 21, X and Y, was performed on 847 amniotic fluid (AF) samples for prenatal aneuploidy screening referred for prenatal aneuploidy screening from 2007 to 2009. The results were then compared to those obtained using conventional cytogenetic analysis. To evaluate the informativity of STR markers, the heterozygosity index of each marker was determined in all the samples. Results: Three autosomes (13, 18, and 21) and X and Y chromosome aneuploidies were detected in 19 cases (2.2%, 19/847) after QF-PCR analysis of the 847 AF samples. Their results are identical to those of conventional cytogenetic analysis, with 100% positive predictive value. However, after cytogenetic analysis, 7 cases (0.8%, 7/847) were found to have 5 balanced and 2 unbalanced chromosomal abnormalities that were not detected by QF-PCR. The STR markers had a slightly low heterozygosity index (average: 0.76) compared to those reported in Caucasians (average: 0.80). Submicroscopic duplication of D13S634 marker, which might be a unique finding in Koreans, was detected in 1.4% (12/847) of the samples in the present study. Conclusion: A QF-PCR assay for prenatal aneuploidy screening was validated in our institution and proved to be efficient and reliable. However, we suggest that each laboratory must perform an independent validation test for each STR marker in order to develop interpretation guidelines of the results and must integrate QF-PCR into the routine cytogenetic laboratory workflow.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

장죽수도 조류관측시스템 구축 후 고찰

  • Lee, Hyeong-Ui;Kim, Mu-Geon;Jang, In-Gwon;Jeong, Yeon-Deuk;Kim, Chan-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.249-251
    • /
    • 2019
  • 장죽수도 조류신호표지시스템 구축을 위하여 시공 전 단계에서 현장해양조사 및 수치모델링을 통한 최적위치를 선정하고 센서 설치 구조안전성 검토 결과를 바탕으로 시공을 수행하였다. 관리자 인터페이스 및 자료 관리를 위한 운용 소프트웨어와 연계하여 장죽수도의 조류정보(유향, 유속, 유속의 경향)를 항해자에게 AIS 정보로 실시간으로 제공하여 통항 선박의 안전운항을 확보하고, 또한 조류관측자료 분석을 통하여 실시간 정확한 조류정보와 예측 값을 반영하여 해양사고를 미연에 방지 할 수 있다.

  • PDF

Identification of Tumor Suppressor Loci on the Long Arm of Chromosome 5 in Primary Small Cell Lung Cancers (원발성 소세포폐암에서 염색체 5번의 장완에 위치한 종양억제유전자좌의 확인)

  • Cho, Eun-Song;Kim, Ho-Guen;Cho, Chul-Ho;Chang, Joon;Chung, Kyung-Young;Kim, Young-Sam;Park, Jae-Min;Kim, Sung-Kyu;Kim, Se-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.49-59
    • /
    • 2000
  • Backgrounds : Recent cytogenetic studies indicated that long of the long arm of chromosome 5 is a frequent event in small cell lung canær (SCLC), suggesting the presence of a tumor suppressor gene in its place. To map the precise tumor-suppressor loci on the chromosome arm for further positional cloning efforts, we tested 15 primary SCLCs. Methods : The DNAs extracted from paraffin-embedded tissue blocks with primary tumor and corresponding control tissue were investigated. Nineteen polymorphic microsatellite markers located in the long arm of chromosome 5 were used in the microsatellite analysis. Results : We found that ten (66.7%) of 15 tumors exhibited LOH in at least one of tested microsatellite markers. Two (13%) of 10 tumors exhibiting LOH lost a larger area in chromosome 5q. LOH was observed in five common deleted regions at 5q. Among those areas, LOH between 5q34-qter and 5q35.2-35.3 was most frequent (75%). LOH was also observed in more than 50% of the tumors at four other regions, between 5q14-15 and 5q23-31, 5q31.1, 5q31.3-33.3, and 5q34-35. Three of 15 tumors exhibited shifted bands in at least one of the tested microsatellite markers. Shifted bands occurred in 2.5% (7 of 285) of the loci tested. Conclusion : Our data demonstrated that at least five tumor-suppressor loci exist in the long arm of chromosome 5 and that they may play an important role in small cell lung cancer tumorigenesis.

  • PDF

Design of ULID-based Location-Sensing Service Model (ULID 기반 위치 인식 서비스 모델의 설계)

  • Nam, Kwang-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.143-154
    • /
    • 2005
  • This paper proposes the location acquisition methods and LBS(location-based services) system using RFID(radio frequency identification) tags with location information in ubiquitous city. Location information is checked using RFID tags attached to various buildings. stores and road signs. And various LBSs are provided based on the location information. Traditionally, when the location information is obtained by a GPS, the precision of the location information may deteriorate due to geographical displacement of a satellite and GPS receivers, for example shadow zone by building, in-door environment, and heavy cloud. The objective of this paper is to provide a ULID(universal location identification) data structure, a ULID-based location acquisition method and an LBS system, in which precise location information is extracted using RFID tags attached to various buildings, stores and road signs and ULID and also danger of information leakage is minimized so that an LBS of ubiquitous environment can be provided to a user.

  • PDF

A Reinvestigation on Key Issues Associated with the Yimjin(1712) Boundary Making and Demarcation: Location of 'Yipjiamlyu' and the Confluence of 'Tomungangweon' into the Sungari River (임진정계시 '입지암류(入地暗流)'의 위치와 '토문강원(土門江源)'의 송화강 유입 여부)

  • Lee, Kang-Won
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.6
    • /
    • pp.571-605
    • /
    • 2015
  • This research revealed that 'Yipjiamlyu' in the Mukedeng's map is geographically 'a beginning point of underf low,' whose location is on the Heishigou's riverbed(E.L. 1,840m) in the NNE side of Daegakbong peak, and that 'Tomungangweon'(Heishigou) is one of the upstream reach of the Sungari River, which, according to historical documents and my fieldwork, Mukedeng also knew at the time of Yimjin(1712) Boundary Making and Demarcation(YBMD). These findings suggest the need to reinterpret the processes of YBMD. Mukedeng set up the Baekdusanjeonggyeobi on the mistaken assumptions on the linkage of 'Yipjiamlyu' and Tumen River. It should have been set up on the Daeyeonjibong peak. Mukedeng found the 'Yipjiamlyu' on the riverbed of 'Tomungangweon'(Heishigou), went downstream, and realized that this river did not flow into the Tumen River. During the search for the source of Tumen River, he found a water stream, and regarded it as the source of Tumen River. He speculated that the water at the 'Yipjiamlyu' flows through the underground to reappear at the his 'identified' source of Tumen River. Consequently, he adjured the construction of demarcation from Baekdusanjeonggyeobi through 'Yipjiamlyu' to the his 'identified' source of Tumen River. The water stream pointed as the source of Tumen River, however, was not part of the upstream reach of Tumen River. Actually, Korean officials, who were in charge of establishing boundary features, set up the demarcation from Baekdusanjeonggyeobi through Huanghuasongdianzi to the true source of Tumen River identified by themselves, which Mukedeng had not intended. The ambiguity of the location of 'Yipjiamlyu' caused a difference between Mukedeng's original request and Korean officials' implementation in the boundary demarcation. Throughout the whole processes of YBMD, Korea(Joseon) and China(Qing) both mistook the real geography of the river system. Their understanding on Yalu River system was correct. But the identification of the spring source of the Tumen River by Korean participants was the only geographically correct result related on this river system in YBMD.

  • PDF