• Title/Summary/Keyword: 원통셀

Search Result 65, Processing Time 0.031 seconds

Multiple linear regression model-based voltage imbalance estimation for high-power series battery pack (다중선형회귀모델 기반 고출력 직렬 배터리 팩의 전압 불균형 추정)

  • Kim, Seung-Woo;Lee, Pyeong-Yeon;Han, Dong-Ho;Kim, Jong-hoon
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this paper, the electrical characteristics with various C-rates are tested with a high power series battery pack comprised of 18650 cylindrical nickel cobalt aluminum(NCA) lithium-ion battery. The electrical characteristics of discharge capacity test with 14S1P battery pack and electric vehicle (EV) cycle test with 4S1P battery pack are compared and analyzed by the various of C-rates. Multiple linear regression is used to estimate voltage imbalance of 14S1P and 4S1P battery packs with various C-rates based on experimental data. The estimation accuracy is evaluated by root mean square error(RMSE) to validate multiple linear regression. The result of this paper is contributed that to use for estimating the voltage imbalance of discharge capacity test with 14S1P battery pack using multiple linear regression better than to use the voltage imbalance of EV cycle with 4S1P battery pack.

EEM Analysis of Open-Typed Cylindrical Shieldcase (양끝이 열린 실드케이스의 FEM해석)

  • Kim, Young-Hak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.767-769
    • /
    • 2017
  • Four-shell open-typed shield case was analyzed using 3D FEM. Analysis Dimension was $2m{\times}2m{\times}2m$. Length of shield case was 0.6m and its diameter was 0.1m, 0.08., 0.06m and 0.04m. Thickness and permeablility of shield case was all 1mm and 50,000. The excited magneic fields were earth magneic fields, which were 24A/m in the holizontal direction and 36A/m in the vertical direction, respectively. During FEM analysis, shield case was located at the direction of holizontal magnetic field and was rotated $90^{\circ}$. Magnetic field was $4.45{\times}10^{-2}A/m$ at the direction of holizontal magnetic field and $6.66{\times}10^{-4}A/m$ at the $90^{\circ}$ rotated direction.

  • PDF

Isogeometric Analysis of Lattice Structures Having Compression-Twist Coupled Deformation (압축-비틀림이 결합된 격자구조의 아이소-지오메트릭 해석)

  • Kang, Se-Hyeon;Choi, Myung-Jin;Oh, Myung-Hoon;Yoon, Min-Ho;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.287-292
    • /
    • 2021
  • We utilized the isogeometric analysis (IGA) method that uses NURBS basis functions in CAD systems, to account for the geometric exactness of a geometrically exact beam deformation, on a new type of metamaterial, twist-translation coupled structure showing a large twist angle. A two-dimensional unit cell structure was embedded in a cylindrical wall, using free-form deformation and an appropriate interpolation scheme. A parametric study on the effects of the dimensions of the cylinder and the number of cells, on the twisting angle was performed. Furthermore, the mechanism of the twist-translation coupled metamaterial was explored through numerical examples.

Multiple Visible Light Receiver Using A Flexible Solar Cell and Cds Cells (플렉시블 솔라셀과 Cds셀을 이용한 다중 가시광 수신기)

  • Lee, Seong-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.432-439
    • /
    • 2018
  • In this paper, an omnidirectional visible light detector was developed by making the detecting surface of a flexible solar cell in a cylindrical form, which has a uniform receiving pattern in the horizontal plane. This solar cell detector receives simultaneously multiple signal lights incident from different directions and provides electrical power to the ASK demodulator in the receiver. In experiments, time division transmission method was used to receive three signal lights incident from different directions to the solar cell detector. Each signal light was ASK modulated using a carrier of 40 kHz, and the synchronizing pulses required for time division transmission were generated by detecting the 120 Hz AC signal included in the indoor illumination lamp with Cds cells. This receiving structure is useful in constructing an $N{\times}1$ optical link in visible light communication.

Design and Analysis of Cloaking Structure Using 2D Transmission Line (2D 전송선을 이용한 Cloaking 구조 설계 및 분석)

  • Kim, Chung-Ju;Lee, Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.875-880
    • /
    • 2011
  • We design and analyze the cloaking circuit using 2D transmission line structure to make up for the weakness of the established cloaking circuit using only lumped inductor and capacitor elements. The 2D transmission line structure enables one to conveniently design the cloaking circuit with available element values. All the necessary analysis and synthesis(design) formulas have been derived. A cloaking circuit for a cylindrical scatterer in free space has been designed based on the provided design formulas and its effects have been investigated using the circuit simulator ADS. The effect of the cloaking medium for this specific case has been observed to be about 10.5 dB.

Effect of Electrolyte Amounts on Electrochemical Properties of Coin-Type Lithium-Ion Cells (액체전해액의 함량에 따른 리튬이온전지 코인셀의 전기화학적 특성 연구)

  • Yoon, Byeolhee;Han, Taeyeong;Kim, Seokwoo;Jin, Dahee;Lee, Yong min;Ryou, Myung-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.21 no.2
    • /
    • pp.39-46
    • /
    • 2018
  • Many studies on the electrochemical performance of Li secondary batteries have been obtained using coin-type cells due to the ease of assembly, low cost and ensuring reproducibility. The coin-type cell consists of a case, a gasket, a spacer disk, and a wave spring. These structural features require a greater amount of liquid electrolyte to assemble than other types of cells such as laminated cells and cylindrical cells. Nevertheless, little research has been conducted on the effect of excess liquid electrolytes on the electrochemical performances of Li secondary batteries. In this study, we investigate the effect of different amounts of electrolyte on the coin-type cells. The amount of electrolytes is adjusted to 30 and $100mg\;mAh^{-1}$. Cycle performances at room temperature ($25^{\circ}C$) and high temperature ($60^{\circ}C$) and high voltage are performed to investigate the electrochemical properties of the different amount of electrolytes. In the case of the unit cell including the electrolyte of $30mg\;mAh^{-1}$, the discharging capacity retention characteristic is excellent in comparison with the case of $100mg\;mAh^{-1}$ under the high temperature and high voltage condition. The former shows a larger increase in internal resistance than the latter, confirming that the amount of electrolyte significantly influences the discharge capacity retention characteristics of the battery.

Free Vibration Analysis of Cylindrical Shell Structures with Stiffeners by Transfer Influence Coefficient Method (전달영향계수법에 의한 원통형 셀 구조물의 자유진동해석)

  • 문덕홍;여동준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.342-348
    • /
    • 1996
  • This paper describes the formulation for the vibration analysis of cylindrical shells with stiffeners by the transfer influence coefficient method. This method was developed on the base of the concept of the successive transmission of dynamic influence coefficients. The simple computational results from a personal computer demonstrate the validity of the present method, that is, the numerical high accuracy and the flexibility of programming, are compared with results of the transfer matrix method. It is also confirmed that the present algorithm could provide the solutions of high accuracy for system with a number of intermediate rigid supports. And all boundary conditions and the intermediate stiff supports such as intermediate rigid supports between shell and foundation can be treated only by adequately controlling the values of the spring constants.

  • PDF

Comparison of equivalent-circuit-model based SOC estimation using the EKF (등가회로 모델링 구성에 따른 확장칼만필터(EKF) 기반 SOC 추정성능 비교분석)

  • Lee, Hyun-jun;Park, Jong-hoo;Kim, Jong-hoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.56-57
    • /
    • 2014
  • 본 논문에서는 $LiCoO_2$ 원통형(cylindrical)셀을 확장칼만필터(extended Kalman filter; EKF) 추정알고리즘에 적용 시 등가회로모델 차이에 따른 SOC(State-of-charge) 추정성능의 비교 분석을 진행하였다. 첫 번째, 등가회로 모델의 성능을 좌우하는 RC-ladder의 개수에 따른 SOC 추정성능의 차이를 비교하였고, 두 번째, 모델 단순화에 따른 불가피한 모델의 에러를 줄이고자 사용되는 노이즈 모델(noise model) 및 데이터 리젝션(data rejection)의 유무에 따른 SOC 추정성능을 비교분석 하였다.

  • PDF

Vibration Analysis of Rotating Thin Shells of Revolution by Finite Element Method (유한요소법에 의한 회전하는 얇은 축대칭 셸의 진동에 관한 연구)

  • 김현실;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.487-496
    • /
    • 1985
  • 회전하는 축대칭 얇은 셸구조물의 진동 특성을 유한요소법에 의하여 해석하였다. 2개의 절점을 가진 Conical Frustrm 형태의 축대칭 요소를 사용하였으며 원주방향의 변위는 Fourier Series로 분해하여서 방정식의 수를 상당히 줄일 수 있었다. Sanders-Koiter의 셸이론을 사용하였으며 진 동 모우드는 회전의 영향을 설명하기 위하여 대칭 및 비대칭 모우드를 모두 고려하였다. Coriolis 행렬을 포함하는 운동방정식에서 고유 진동수를 계산하기 위해서 질량, 강성 및 Coriolis 행렬로 이루어지는 Hermitian 행렬의 Sturm Sequence Property를 이용하였으며, 좁은 밴드를 갖는 대형 행렬에 알맞는 Determinant Search 방법을 확장하여 고유진동수 및 벡터를 구하였다. 원통형 셸에 대하여 정지한 경우 계산한 고유진동수를 실험치 및 이론치와 비교한 결과 잘 일치됨을 알 수 있었다. 여러 가지 회전 속도에 대해서 얻어진 고유진동스를 이론치와 비교한 결과 잘 일치 됨을 알 수 있어\ulcorner며 회전의 영향으로 traveling wave진동의 현상이 나타남을 알 수 있었다.

A study on the change of electrical and thermal characteristics for battery module by aging (배터리 모듈 노화에 따른 전기적 특성 및 열 거동 변화 특성 분석 연구)

  • Park, Seongyun;Lee, Pyeongyeon;Kim, Jonghoon;Park, Sungbeak;Kim, Youngmi
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.178-179
    • /
    • 2019
  • 최근 다양한 어플리케이션에서 리튬 이온 배터리가 사용됨에 따라 이에 대한 연구가 활발히 이루어지고 있다. 전기 자동차(Electric Vehicles; EVs) 및 에너지저장장치(Energy Storage Systems; ESSs) 등의 개발로 대형 배터리 시스템이 요구되고 있으며, 이의 해석이 요구되고 있다. 본 논문에서는 18650 원통형 셀로 구성된 14S20P 배터리 모듈의 노화에 따른 전기적 특성 및 열 거동 변화를 분석하였다.

  • PDF