• Title/Summary/Keyword: 원접촉

Search Result 705, Processing Time 0.029 seconds

Applications of Nanomanipulator in Nanowires (나노메니퓰레이터를 이용한 나노선의 특성평가)

  • Yoon, Sang-Won;Seo, Jong-Hyun;Ahn, Jae-Pyoung;Seong, Tae-Yeon;Lee, Kon-Bae
    • Journal of Powder Materials
    • /
    • v.16 no.2
    • /
    • pp.138-145
    • /
    • 2009
  • The combination of focused ion beam (FIB) and 4 point probe nanomanipulator could make various nano manufacturing and electrical measurements possible. In this study, we manufactured individual ZnO nanowire devices and measured those electrical properties. In addition, tensile experiments of metallic Au and Pd nanowires was performed by the same directional alignment of two nanomanipulators and a nanowire. It was confirmed from I-V curves that Ohmic contact is formed between electrodes and nanomanipulators, which is able to directly measure the electrical properties of a nanowire itself. In the mechanical tensile test, Au and Pd nanowires showed a totally different fracture behavior except the realignment from <110> to <002>. The deformation until the fracture was governed by twin for Au and by slip for Pd nanowires, respectively. The crystallographic relationship and fracture mechanism was discussed by TEM observations.

Epidemiological Observation on Recent Outbreaks of Canine Distemper in Korea (최근 국내발병 개 디스템퍼에 대한 역학적 조사)

  • Doo, Kim;Ji-young, Park;So-jeo, Ahn;Seok-young, Jeoung;Son-il, Pak
    • Journal of Veterinary Clinics
    • /
    • v.21 no.3
    • /
    • pp.229-235
    • /
    • 2004
  • To characterize the recent outbreaks of canine distemper (CD) in Korea, we carried out epidemiological investigations by clinical observations, serum neutralizing (SN) antibody titer determination and RT-PCR on the 315 dogs which were clinically suspected as canine distemper virus (CDV) infection. One hundred and sixty two of 315 dogs were infected with CDV. Breed or gender did not seem to have effects on the prevalence of CD. The major part of dogs were in young age from 6 weeks to 18 weeks of age, and were not vaccinated or incompletely vaccinated. Clinical signs of dogs with CD were multi systemic and extremely variable. Dogs died from CD had significantly more ocular signs and neurologic signs than those of dogs survived (p<0.05). The SN titers against CDV of 157 (96.9%) dogs were under 1:16, which is less than protective level. One possible explanation for recent outbreaks of CD in Korea might be low antibody titers against CDV because of vaccination failure. Therefore, to reduce the impact of virulent infection in the dog population, dogs should be vaccinated adequately and prophylactic measures should include isolation of young dogs from the dog population until vaccination can be expected to provide protection.

The Effect of Graphene on the Electrical Properties of a Stretchable Carbon Electrode (그래핀 첨가에 따른 신축성 카본전극의 전기적 특성 변화)

  • Lee, T.W.;Park, H.H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.77-82
    • /
    • 2014
  • Stretchable electrodes are focused due to many demands for soft electronics. One of the candidates, carbon black composites have advantages of low cost, easy processing and decreasing resistivity in a certain range during stretching. However, the electrical conductivity of carbon black composites is not enough for electronic devices. Graphene is 2-dimensional nanostructured carbon based material which shows good electrical properties and flexibility. They may help to improve electrical conductivity of the carbon black composites. In this study, graphene was added to a carbon black electrode to enhance electrical properties and investigated. Electrical resistivity of graphene added carbon electrode decreased comparing with that of carbon black electrode because graphene bridged non-contacting carbon black aggregates to strengthen the conductive network. Also graphene reduced an increase in the resistance of the carbon black electrode applied to strain because they connected gap of separated carbon black aggregates and aligned along the stretching direction at the same time. In conclusion, an addition of graphene to carbon black gives two benefits on the electrical properties of carbon black composite as a stretchable electrode.

Effect of Implant Length on the Immediate Loading at the Anterior Maxilla (즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구)

  • Lee, Joon-Seok;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2009
  • Recently many studies have been published on application of immediate loaded implants. However, the immediate loading protocol has not been well documented. The purpose of the present study was to evaluate the stress distribution between bone-implant interfaces and the effect of implant length in the anterior maxilla using 3 dimensional finite element analyses. The diameter 4.0 mm threaded type implants with different length(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm) were used in this study. The bone quality of anterior maxillary bone block was assumed to D3 bone. Bone-implant interfaces of immediately loaded implant were constructed using a contact element for simulating the non osseointegration status. For simplification of all the processing procedures, all of the material assumed to be homogenous, isotropic, and linearly elastic. The 178 N of static force was applied on the middle of the palatoincisal line angle of the abutment with $120^{\circ}$ angle to the long axis of abutment. Maximum von Mises stress were concentrated on the labial cortical bone of the implant neck area, especially at the cortical-cancellous bone interfaces. Compared the different length, highest peak stress value was observed at the 8.5 mm implants and the results indicated a tendency towards favorable stress distribution on the bone, when the length was increased. Presence of cortical bone was very important to immediate loading, and it appears that implants of a length more than 13 mm are preferable for immediate loading at the anterior maxilla.

Improvement of High-Temperature Performance of LiMn2O4 Cathode by Surface Coating (표면코팅을 통한 LiMn2O4 양극의 고온성능 개선)

  • Lee, Gil-Won;Lee, Jong-Hwa;Ryu, Ji-Heon;Oh, Seung-M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.1
    • /
    • pp.81-87
    • /
    • 2009
  • An indium-tin oxide (ITO) coated spinel manganese oxide (${LiMn_2}{O_4}$, LMO) is prepared and its high-temperature ($55^{\circ}C$) cycle performance and rate capability are examined. A severe electrolyte decomposition and film deposition is observed on the un-coated ${LiMn_2}{O_4}$ cathode, which leads to a significant electrode polarization and capacity fading. Such an electrode polarization is, however, greatly reduced for the ITO-coated (> 2 mol%) LMO cathode, which leads to an improved cycle performance. This can be rationalized by a suppression of electrolyte decomposition, which is in turn indebted to a decrease in the direct contact area between LMO and electrolyte. The suppression of film deposition on the ITO-coated LMO cathode is confirmed by infra-red spectroscopy. The rate capability is also improved by the surface coating, which may be resulted from a suppression of resistive film deposition and high electric conductivity of ITO itself.

Analysis on infection control of general hospital radiology (종합병원 영상의학과의 감염관리 대한 분석)

  • Shin, Jung-Sub;Park, Cheol-Woo;Jeon, Byeong-Kyou
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.335-342
    • /
    • 2012
  • This study aims to find a way to control infection of community radiology effectively by calculating the degree of contamination, culture and identifying the flora in radiology of five general hospitals in Gyeongsangbuk-do. Staphylococcus, Micrococcus, Pseudomonas stutzeri, Pseudomonas oryzihabitans were identified as surface flora. These are know to be pathogens of hospital acquired infection and there was no radiology-specific flora. Research subject hospitals were conducting similar infection control education but degree of contamination of each hospital showed significant difference. Difference in degree of contamination according to contact sources were analyzed by Contact sources were classified into technologist-using, patients-using and common-using materials. Analysis of each hospital's degree of contamination showed that patient-using materials were significantly more contaminated than technologist-using and common-using materials (p<0.001). Devices which are similar to each other in monthly average frequency of use showed no significant difference in degree of contamination, but general X-ray devices and chest boards which are used most frequently showed higher degree of contamination than others. In addition, hospital A, B and C which have heavier monthly average caseload showed relatively high degree of contamination on irradiation devices which are used by technologists only or by technologists and patients commonly, office desks and doorpulls. Hence it is considered that intensity of infection control education should be different according to the degree of monthly average caseload. This study provided an opportunity to aware that technologists' feeling of contamination is crucial for infection control of radiology, and the Accupoint ATP public hygiene monitoring system which was used in this study for measuring the degree of contamination was proved to be an effective measuring device for hospital acquired infection management.

An epidemiological survey of Cryptosporidium parvum infection in randomly selected inhabitants of Seoul and Chollanam-do (서울 및 전남 지역 주민의 작은와포자충 감염에 대한 역학조사)

  • 채종일;이상협
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.2
    • /
    • pp.113-120
    • /
    • 1996
  • An epidemiological survey was performed to know the status of Cwptespori,mum sp. infection among the people in Seoul and Chollanam-do in 1992. One village of Chollanam-do (Hwasun-gun) which showed the highest oocyst positive rate was re-surveyed in 1995 for human infection and for cattle also. The subjected areas consisted of 8 urban villages (: dongs) of Seoul and 4 urban (: dongs) and 7 rural (: myonsl villages of Chollanam-do. A total of 3,146 fecal samples was collected randomly, and smears were made from formalin-ether sediments. They were examined for Cwptosporinium oocysts by modified acid fast staining. The overall oocyst positive rate was 79% (248/3,146), but the rate was remarkably different between Seoul and Chollanam-do, 0.5% (4/853) and 10.6% (244/2,293), respectively The average size of oocysts was 4.8 ± 0.5 by 4.2 ± 0.5 ㎛, compatible with C. pcnlum. In Chollanam-do, rural villages showed significantly higher rate (14.0%) than urban villages (3.7%). Especially the people in Iyang-myon, Hwasun- gun, a typical rural village, revealed a very high rate of 40.0% (74/185). Adults aged 51-70 years revealed the highest positive rate among all age groups. At the re-survey of the same village of Hwasun-fun in 1995, 44 (35.2%) of 125 villagers and 14 (93.3%) of IS cattle examined were positive for C. pnnpum oocysts. The results suggest that C. pnnpum is highly prevalent in rural areas of Chollanam-do, and an important source or mode of infection seems to be contaminated water or contact with the feces of infected cattle.

  • PDF

A Study on the Impact Fracture of Fragile Materials (취성재료의 충격파괴에 관한 연구 II)

  • 양인영;김택현;정낙규;이상호;김선규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1417-1425
    • /
    • 1990
  • In this paper, when the glass plate of fragile material is subjected to impact load, the fracture pattern and the generation phenomenon of cone crack were theoretically clarified by using the analysis method of impulsive stress in the first paper. The numerical analysis results of strain distribution at a distance of 0.1cm, from the impact loading point to 5cm, were compared with experimental results. The main conclusions obtained are as follows; (1) The generation phenomenon of cone crack at the impact fracture of the glass plate can be analytically confirmed by using the three dimensional dynamic theory of elasticity. And the numerical analysis results of strain distribution using this theory are relatively in close agreement with the crack size obtained from the impact fracture experiment. (2) After the stress wave generated at the impact point propagated to the spherical compressive wave, this stress wave reflected from the back surface and reached again at the surface of the plate to the spherical stress wave. Then the generation of cone crack can be confirmed along the stress wave surface. (3) The plate is the thicker, the more is the generation phenomenon of cone crack at the lower impact velocity range (20m/s-35m/s). Because the fracture generate before the maximum tensile stress acting to the glass plate, cone crack was rarely ever generated.

Precise Detection of Buried Underground Utilities by Non-destructive Electromagnetic Survey (비파괴 전자탐사에 의한 지하 매설물의 정밀탐지)

  • Shon, Ho-Woong;Lee, Seung-Hee;Lee, Kang-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2002
  • To detect the position and depth of buried underground utilities, method of Ground Penetrating Radar(GPR) survey is the most commonly used. However, the skin-depth of GPR is very shallow, and in the places where subsurface materials are not homogeneous and are compose of clays and/or salts and gravels, GPR method has limitations in application and interpretation. The aim of this study is to overcome these limitations of GPR survey. For this purpose the site where the GPR survey is unsuccessful to detect the underground big pipes is selected, and soil tests were conducted to confirm the reason why GPR method was not applicable. Non-destructive high-frequency electromagnetic (HFEM) survey was newly developed and was applied in the study area to prove the effectiveness of this new technique. The frequency ranges $2kHz{\sim}4MHz$ and the skin depth is about 30m. The HFEM measures the electric field and magnetic field perpendicular to each other to get the impedance from which vertical electric resistivity distribution at the measured point can be deduced. By adopting the capacitive coupled electrodes, it can make the measuring time shorter, and can be applied to the places covered by asphalt an and/or concrete. In addition to the above mentioned advantages, noise due to high-voltage power line is much reduced by stacking the signals. As a result, the HFEM was successful in detecting the buried underground objects. Therefore this method is a promising new technique that can be applied in the lots of fields, such as geotechnical and archaeological surveys.

Dynamic Characteristics of Actuator for High Density Optical Recording Pick-up (고밀도 기록용 광픽업의 ACTUATOR 동특성)

  • 임경화;이용훈;김석중;이재원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.258-263
    • /
    • 1995
  • 미래 정보와 시대에서 중추적인 역할을 할 광관련 멀티미디어 장비들은 최근 관련 산업계에서 주목을 받기 시작하고 있고 특히 기존 VTR(Video Tape Recorder) 시장을 대체할 차세대 DVDR(Digital Video Disk Recorder)는 기술전쟁이라고 할 정도로 선진 기업의 연구가 치열해지고 있다. DVDR 시스템에서는 필요한 정보들을 레이저빔을 이용한 광학신호로 바꾸어 광디스크에 기록, 재생하는 광픽업이 절대적으로 필요하게 된다. 그런데 광픽업의 위치추종기구인 Actuator는 정확한 위치추종(.+-.1.$\mu$m 오차이내)을 할 수 있는 성능이 요구되며 서보의 특성상 20KHz 이하에서 불필요한 모우드가 가진되지 않는 정밀부품이어야 하므로 Actuator 각 부품의 동적인 특성을 명확히 규명할 필요가 있다. 따라서 본 연구에서는 우선 Actuator 각 부품과 가동부 전체의 중량 및 진동해석을 통해 동특성을 조사하였다. 그리고 Actuator의 중요한 기본성능중 하나인 구동감도 확보여부를 검토할 필요가 있기 때문에 유한요소법 프로그램인 ANSYS를 이용하여 자기회로 부분에 대한 해석을 구하였다. 또한 가동부와 자기회로 등 하위부품을 조립하는 과정에서 발생하는 조립오차로 인해 불필요한 공진과 회전형상이 야기될 수 있으므로 동특성 및 문제점 파악을 위한 민감도 분석이 필요하다. 따라서 본 연구에서는 가동부의 관성 모멘트 값과 강체에 대한 일반식을 이용한 자체 프로그램을 작성하여 조립공차를 구하였다. 이와같은 과정을 통해 구해진 설계값을 바탕으로 실제 제작된 Actuator에 대해서는 비접촉식 측정방법을 통해 동특성값을 측정하였고 이를 해석값과 상호 비교하였다.동강성행렬법(dynamic stiffness matrix method)을 이용하여 해석하고자 한다. 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.ive structures utilized in Client/server architecture for distribution and cooperative processing of application between server and client this study presents two different data management methods under the Client/server environment; one is "Remote Data Management Method" which uses file server or database server and. the other is "Distributed Data Management Method" using distributed database management system. The result of this study leads to the conclusion that in the client/server environment although distributed application is assumed, the data could become centralized (in the case of file server or database server) or decentralized (in the case of distributed

  • PDF