• Title/Summary/Keyword: 원접촉

Search Result 705, Processing Time 0.021 seconds

Antibacterial and Antiviral Activities of Multi-coating Polyester Textiles (다중 코팅 폴리에스터 섬유 여재의 항균 및 항바이러스 특성)

  • Ko, Sangwon;Lee, Jae-Young;Park, Duckshin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.444-450
    • /
    • 2022
  • The effect of coated polyester (PET) textiles with metal oxide, chitosan, and copper ion on the antibacterial and antiviral activities was evaluated to investigate the applicability of multi-coated PET textiles as antiviral materials. Compared to coated PETs with a single agent, multi-coated PETs reduced the loading amount of coating materials as well as the contact time with bacteria for a bacterial cell number of < 10 CFU/mL, which was not detectable with the naked eyes. Metal oxides generate reactive oxygen species (ROS) such as free radicals by a catalytic reaction, and copper ions can promote contact killing by the generation of ROS. Chitosan not only enhanced antibacterial activities due to amine groups, but enabled it to be a template to load copper ions. We observed that multi-coated PET textiles have both antibacterial activities for E. coli and S. aureus and antiviral efficiency of more than 99.9% for influenza A (H1N1) and SARS-CoV-2. The multi-coated PET textiles could also be prepared via a roll-to-roll coating process, which showed high antiviral efficacy, demonstrating its potential use in air filtration and antiviral products such as masks and personal protective equipment.

Numerical Analyses on the Behavioral Characteristics of Side of Drilled Shafts in Rocks and Suggestion of Design Charts (수치해석을 통한 암반에 근입된 현장타설말뚝의 주면부 거동특성 분석 및 설계차트 제시)

  • Lee, Hyuk-Jin;Kim, Hong-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6C
    • /
    • pp.407-419
    • /
    • 2006
  • Situations where support is provided solely in shaft resistance of drilled shafts are where the base of the drilled hole cannot be cleaned so that it is uncertain that any end bearing support will be developed. Alternatively, where sound bed rock underlies low strength overburden material, it may be possible to achieve the required support in end bearing on the rock only, and assume that no support is developed in the overburden. However, where the drilled shaft is drilled some depth into sound rock, a combination of side wall resistance and end bearing can be assumed. Both theoretical and field studies of the performance of rock socketed drilled shafts show that the major portion of applied load is usually carried in side wall resistance. Normal stress at the rock-concrete interface is induced by two mechanisms. First, application of a compressive load on the top of the pile results in elastic dilation of the concrete, and second, shear displacement at the rough surface of the drilled hole results in mechanical dilation of the interface. If the stiffness of the material surrounding the socket with respect to normal displacement is constant, then the normal stress will increase with increasing applied load, and there will be a corresponding increase in the shear strength. In this study, the numerical analyses are carried out to investigate the behavioral characteristics of side of rock socketed drilled shafts. The cause of non-linear head load-settlement relationship and failure mechanism at side are also investigated properly and the design charts are suggested and verified for the leading to greater efficiency and reliability in the pile design.

Estimation of Bridge Vehicle Loading using CCTV images and Deep Learning (CCTV 영상과 딥러닝을 이용한 교량통행 차량하중 추정)

  • Suk-Kyoung Bae;Wooyoung Jeong;Soohyun Choi;Byunghyun Kim;Soojin Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.10-18
    • /
    • 2024
  • Vehicle loading is one of the main causes of bridge deterioration. Although WiM (Weigh in Motion) can be used to measure vehicle loading on a bridge, it has disadvantage of high installation and maintenance cost due to its contactness. In this study, a non-contact method is proposed to estimate the vehicle loading history of bridges using deep learning and CCTV images. The proposed method recognizes the vehicle type using an object detection deep learning model and estimates the vehicle loading based on the load-based vehicle type classification table developed using the weights of empty vehicles of major domestic vehicle models. Faster R-CNN, an object detection deep learning model, was trained using vehicle images classified by the classification table. The performance of the model is verified using images of CCTVs on actual bridges. Finally, the vehicle loading history of an actual bridge was obtained for a specific time by continuously estimating the vehicle loadings on the bridge using the proposed method.

휴대형 당도판정센서를 이용한 배의 당도 판정

  • 이강진;최규홍;강석원;최완규;손재룡
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.120-121
    • /
    • 2003
  • 과수원에서 재배되는 배는 과수원 내의 위치, 시비, 토양 등의 요인에 따라 다양한 품질을 나타내며, 당도와 숙도의 편차가 크기 때문에 과수농가에서는 경험에 의존하여 적정 숙기로 판단되는 배를 수확하고 있다. 그러나 과학적이지 못한 사실에 기초한 수확 관행은 시장유통되는 배에 대하여 소비자들의 신뢰성 저하를 초래하게 되고 소비 감소와 더불어 농가 소득 감소로 이어지게 된다. 최근, 전국의 청과물 산지유통센터에는 근적외선을 이용하여 과일 내부의 당도, 산도, 결함 등을 실시간으로 판정할 수 있는 비파괴 선별기가 보급되고 있으나 이는 수확이후의 선별.규격화 유통을 위한 것이다. 본 연구에서는 이와는 달리, 수확 이전, 즉 재배 단계에서 배의 당도와 숙도를 판정하여 수확적기를 판단할 수 있도록 나무에 매달린 배에 대하여 가시광선과 근적외선 반사스펙트럼을 측정할 수 있고 이를 이용하여 당도와 숙도가 판정가능한 휴대형 센서를 개발하였으며, 개발된 시작기를 이용하여 당도판정의 가능성을 시험하였다. 휴대형 당도판정센서는 광원과 광섬유프로브, 광검출부, 당도판정부, 전원공급부로 구성된다. 광원은 할로겐램프(6V)를 이용하였고, 광섬유프로브는 동심원 형태로서 외부의 광섬유를 통하여 광원에서 시료로 빛이 조사되게 하고, 내부의 광섬유를 통하여 광검출기로 확산반사되는 광이 전달될 수 있도록 하였다. 전원공급부는 휴대와 충전이 가능한 배터리(12V, 2AH)와 이 배터리에서 정전류가 광원으로 보내어 질 수 있도록 제작된 회로로 구성하였다. 당도 판정을 위하여 518nm에서 1046nm의 파장대역에서의 반사스펙트럼을 이용하였고, 레퍼런스로써 백색 테플론 구를 제작하여 사용하였다. 수원 농산물 도매시장에서 판매중인 2002년산 신고 배를 구매하고, 시작기를 이용하여 총 113개의 배에 대한 반사스펙트럼을 측정하였다. 다음으로 굴절당도계로 당도값을 측정하고 반사스펙트림을 이용하여 당도값을 예측하기 위한 부분최소제곱회귀(PLSR)모델을 개발하였다. 여기서 모델의 정밀도는 교차검정법을 이용하여 검증하였다. 시료 표면과 광섬유프로브와의 접촉상태 불균일, 광원의 시간에 따른 경시 변화, 과일 형상의 차이 등에 의하여 측정된 반사스펙트럼은 상당한 변이를 나타내었으므로 이를 보정하기 위하여 반사 스펙트럼은 다분산보정처리하여 이용하였다. 당도 예측용 PLSR모델 개발의 결과, 모델의 결정계수($R^2$)는 0.67, SEC는 $\pm$0.4brix.로 나타났으며, 교차검정에 의한 미지 시료의 예측에서 총 113개의 미지 시료에 대한 결정계수는 0.57, SEP는 $\pm$ 0.46brix.로 나타났으며, 이는 현장에서 충분히 활용가능할 것으로 판단되었다. 금후, 전체 시스템의 부피와 중량을 줄이고 각 부분품들의 전력소모의 최소화할 수 있도록 개선할 계획이다.

  • PDF

An effect on the Job-satisfaction and Service quality of the effect factor on Job-satisfaction on Family Restaurant Service Staff. (외식업체 종사원의 직무만족 영향요인이 직무만족과 서비스품질에 미치는 영향)

  • Lee, Hyeong-Baek;No, Jin-Ok
    • Proceedings of the Korea Hospitality Industry Research Society Conference
    • /
    • 2005.11a
    • /
    • pp.1-20
    • /
    • 2005
  • Family Restaurant is a service business of a kind. The role of service operator is to improve a sales of service goods through maximizing the service value with customer satisfaction at the moment of MOT(moment of truth). Family Restaurant come to the great growth on the face of it. In future, it will place emphasis more and more on not hardware but software including service quality. The purpose of this study, therefore, is to research the effect on service quality of the job satisfaction of Family Restaurant's service staff. Data was collected from the employee who are working at Family Restaurant located in Taegu. The empirical research has been done over 50days from 1April, 2004 to 20May, 2004. In conclusion of empirical analysis, 4 hypotheses were significant among 7 hypotheses suggested in this study. The research showed as follows : First, the organic trait among the effect factor of job satisfaction perceived by Family Restaurant service staff showed positive influence on job satisfaction. Second, the personal trait among the effect factor of job satisfaction perceived by Family Restaurant service staff showed positive influence on service quality. Third, the official trait among the effect factor of job satisfaction perceived by Family Restaurant service staff showed negative influence on job satisfaction. Fourth, the organic trait among the effect factor of job satisfaction perceived by Family Restaurant service staff showed positive influence on service quality. Fifth, the personal trait among the effect factor of job satisfaction perceived by Family Restaurant service staff showed negative influence on service quality. Sixth, the organic trait among the effect factor of job satisfaction perceived by Family Restaurant service staff showed negative influence on service quality. Seventh, the job satisfaction of Family Restaurant service staff showed positive influence on service quality. Besides, the critical points of this study are as follows; First, we designated the subject of research to the employee of Family Restaurant only. Second, multi-situations(time, holiday) which can happen as service was offered, wasn't concerned. Third, as service quality was estimated by general service quality. the research in future should subdivide service quality more. I. finally, applied the pervious researches on job satisfaction and service quality in the employee of Family Restaurant. To extend more this research model in future, the variables like customer satisfaction should be added.

  • PDF

Preparation of Polysulfone Composite Ultrafiltration Hollow Fiber Membranes Incorporating Nano-size Fumed Silica with Enhanced Antifouling Properties (나노 크기의 Fumed Silica가 함유된 Polysulfone 한외여과 중공사막 제조 및 내오염성 분석)

  • Kang, Yesol;Lim, Joohwan;Kim, In S.
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.379-387
    • /
    • 2018
  • This study was conducted to improve the membrane characteristics and performance by increasing hydrophilicity by adding additives to the ultrafiltration polysulfone (PSf) hollow fiber membrane. The mixed matrix membranes (MMMs) were prepared by dispersing 15 nm of fumed silica (FS) in the spinning solution at 0.1, 0.3 and 0.5 wt%. SEM analysis was carried out to confirm the cross-section and surface condition. It was confirmed that mean pore radius of the hollow fiber increased by 4 nm as FS was added. In addition, contact angle measurement was carried out for the hydrophilicity analysis of hollow fiber membranes, and it was confirmed that the hydrophilicity of MMMs were increased by adding of FS. In the case of water permeability, the membrane including FS showed 91~96 LMH and showed 5~11% more increase than PSf membrane. In the antifouling performance test, relative flux reduction ratios of FS mixed hollow fiber membranes were lower than that of PSf membranes, and it was confirmed that increase of hydrophilicity hinders adsorption of hydrophobic BSA on the membrane surface.

Hydrophilic Modification of Porous Polyvinylidene Fluoride Membrane by Pre-irradiating Electron Beam (전자빔 전조사를 이용한 Polyvinylidene Fluoride 다공막의 친수화 개질)

  • Choi, Yong-Jin;Lee, Sung-Won;Seo, Bong-Kuk;Kim, Min
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.118-126
    • /
    • 2011
  • A method of light pre-irradiation, one of methods modifying hydrophobic surface to hydrophilic surface in a membrane, was proposed to overcome the drawback of previous methods such as blending, chemical treatment and post-irradiation, Process of membrane preparation in the study was comprised of 4 parts as follows: firstly process of precursor preparation to introduce hydrophilic nature under atmosphere and aqueous vapor by irradiating electron beam (EB), secondly process of dope solution preparation to cast on non-woven fabrics, thirdly process of casting to prepare membrane and finally process of coagulation in non-solvent to form porous structure. The merit of this method might show simple process as well as homogenous modification compared to previous methods. To carry it out, precursor was prepared by irradiating EB to powder PVDF at 75~125 K Gray dose. Precursor prepared was analyzed by FTIR, EDS and DSC to confirm the introduction of hydrophilic function and its mechanism. From their results, it was inferred I conformed that hydrophilic function was hydroxy1 and it was introduced by dehydrozenation. Hydrophilicity of membranes prepared was evaluated by contact angle (pristine PVDF : $62^{\circ}$, 125 K Gray-PVDF$13^{\circ}$). Porosity was evaluated by mercury intrusion method, simultaneously morpholoy and surface pore size were observed by SEM phothographs. The result showed the trend that more dose of EB led to smaller pore size and to lower porosity (pristine PVDF : 82%, 125 K Gray-PVDF : 63%). Trend of water permeability was similar to result above (pristine PVDF : 892 LMH, 125 K Gray-PVDF : 355 LMH).

Residual Toxicity of Bifenthrin and Imidacloprid to Honeybee by Foliage Treatment (Bifenthrin과 Imidacloprid의 작물잎에서의 잔류량과 꿀벌에 대한 독성)

  • Cho, Kyung-Won;Park, Hyun-Ju;Bae, Chul-Han;Kim, Yeon-Sik;Shin, Dong-Chan;Lee, Seung-Yeol;Lee, Suk-Hee;Jung, Chang-Kook;Park, Yeon-Ki;Kim, Byung-Seok;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.3
    • /
    • pp.226-234
    • /
    • 2010
  • Foliage residue toxicity experiment was performed against honeybee (Apis mellifera) with bifenthrin, a synthetic pyrethroid insecticide with strong acute contact toxicity and imidacloprid, a neo-nicotinoid insecticide with strong acute oral toxicity to know the honeybee toxicity at the residue level on the leaves of alfalfa and apple. Also, the formulation differences to honeybee toxicity were investigated with WP (2%) and EC (1%) of bifenthrin and WP (10%) and SL (4%) of imidacloprid. Generally, foliage residual toxicity of honeybee and residual amounts of tested insecticides was higher in alfalfa leaves with large leaf area per unit weight than in apple leaves. While on the other hand, the only bifenthrin WP treatment showed higher honeybee toxicity on apple leaves than alfalfa. Although imidacloprid showed higher residue amounts ranged $4.9{\sim}25.4\;mg{\cdot}kg^{-1}$ than bifenthrin ranged $0.6{\sim}12.7\;mg{\cdot}kg^{-1}$ on the leaves, the residual toxicity to honeybee was lower than bifenthrin because of its strong penetration character. In conclusion, the residual toxicity of insecticide to honeybee could be affected by the contact and vaporized toxicity of chemical, the residual amounts on the surface of leaves, and the leaf area per unit weight and formulation differences.

Three-dimensional finite element analysis for stress distribution on the diameter of orthodontic mini-implants and insertion angle to the bone surface (교정용 미니임플랜트의 직경 및 식립각도에 따른 응력 분포에 관한 3차원 유한요소 분석)

  • Byoun, Na-Young;Nam, Eun-Hye;Kim, Il-Kyu;Yoon, Young-Ah
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.178-187
    • /
    • 2006
  • The present study was performed to evaluate the stress distribution on the diameter of the mini-implant and insertion angle to the bone surface. To perform three dimensional finite element analysis, a hexadron of $15{\times}15{\times}20mm^3$ was used, with a 1.0 mm width of cortical bone. Mini-implants of 8 mm length and 1.2 mm, 1.6 mm, and 2.0 mm in diameter were inserted at $90^{\circ},\;75^{\circ},\;60^{\circ},\;45^{\circ},\;and\;30^{\circ}$ to the bone surface. Two hundred grams of horizontal force was applied to the center of the mini-implant head and stress distribution and its magnitude were analyzed by ANSYS, a three dimensional finite element analysis program. The findings of this study showed that maximum von Mises stresses in the mini-implant and cortical and cancellous bone were decreased as the diameter increased from 1.2 mm to 2.0 mm with no relation to the insertion angle. Analysis of the stress distribution in the cortical and cancellous bone showed that the stress was absorbed mostly in the cortical bone, and little was transmitted to the cancellous bone. The contact area increased according to the increased diameter and decreased insertion angle to the bone surface, but maximum von Mises stress in cortical bone was more significantly related with the contact point of the mini-implant into the cortical bone surface than the insertion angle to the bone surface. The above results suggest that the maintenance of the mini-implant is more closely related with the diameter and contact point of the mini-implant into the cortical bone surface rather than the insertion angle.

Effect of Ozone Application on Sulfur Compounds and Ammonia Exhausted from Aerobic Fertilization System of Livestock Manure (가축분뇨 호기적 퇴.액비화시 발생하는 기체 중의 황 화합물과 암모니아에 대한 오존처리 효과)

  • Jeong, Kwang Hwa;Whang, Ok Hwa;Khan, Modabber Ahmed;Lee, Dong Hyun;Choi, Dong Yoon;Yu, Yong Hee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.118-126
    • /
    • 2012
  • In this study, two types of ozone generating experimental instrument were installed in commercial livestock manure fertilization facility, which can treat hundred tons of pig manure in a day. Gas samples to be treated were collected from the upper part of the liquid fertilization system and composting system of the commercial livestock manure fertilization facility. The gas sample was flowed to oxidation reactor through pipe line by suction blower, therefore, contacted with ozone. Ammonia and sulfur compounds of gas samples collected from the inlet and outlet point of the experimental instrument were analyzed. The oxidation effect by the contact with ozone was higher in sulfur compounds than ammonia. Ammonia content was reduced about 10% by ozone contact. Sulfur compounds, on the other hand, reduced significantly while treated with ozone. In case of gas sample collected from liquid fertilization system, the concentrations of hydrogen sulfide ($H_2S$), methyl mercaptan (MM), dimethyl sulfide (DMS), and dimethyl disulfide (DMDS) of inlet gas were 50.091, 4.9089, 27.8109 and 0.4683 ppvs, respectively. After oxidized by ozone, the concentrations of sulfur compounds were 1.2317, 0.3839, 14.7279 and 0.3145 ppvs, respectively. Another sample collected from aerobic composting system was oxidized in the same conditions. The concentrations of $H_2S$, MM, DMS and DMDS of the sample collected from inlet point of the reactor were 40.6682, 1.3675, 24.2458 and 0.8289 ppvs, respectively. After oxidized, the concentrations of $H_2S$, MM, DMS, and DMDS were reduced to 3.013, ND, 8.8998 and 0.3651 ppvs, respectively. By application of another type of ozone, the concentrations of $H_2S$, MM, DMS and DMDS of inlet gas were reduced from 43.397, 1.4559, 3.6021 and 0.4061 to ND, ND, ND, and 0.21ppvs, respectively.