Browse > Article

Three-dimensional finite element analysis for stress distribution on the diameter of orthodontic mini-implants and insertion angle to the bone surface  

Byoun, Na-Young (Department of Dentistry, College of Medicine, Inha University)
Nam, Eun-Hye (Department of Dentistry, College of Medicine, Inha University)
Kim, Il-Kyu (Department of Dentistry, College of Medicine, Inha University)
Yoon, Young-Ah (Department of Dentistry, College of Medicine, Inha University)
Publication Information
The korean journal of orthodontics / v.36, no.3, 2006 , pp. 178-187 More about this Journal
Abstract
The present study was performed to evaluate the stress distribution on the diameter of the mini-implant and insertion angle to the bone surface. To perform three dimensional finite element analysis, a hexadron of $15{\times}15{\times}20mm^3$ was used, with a 1.0 mm width of cortical bone. Mini-implants of 8 mm length and 1.2 mm, 1.6 mm, and 2.0 mm in diameter were inserted at $90^{\circ},\;75^{\circ},\;60^{\circ},\;45^{\circ},\;and\;30^{\circ}$ to the bone surface. Two hundred grams of horizontal force was applied to the center of the mini-implant head and stress distribution and its magnitude were analyzed by ANSYS, a three dimensional finite element analysis program. The findings of this study showed that maximum von Mises stresses in the mini-implant and cortical and cancellous bone were decreased as the diameter increased from 1.2 mm to 2.0 mm with no relation to the insertion angle. Analysis of the stress distribution in the cortical and cancellous bone showed that the stress was absorbed mostly in the cortical bone, and little was transmitted to the cancellous bone. The contact area increased according to the increased diameter and decreased insertion angle to the bone surface, but maximum von Mises stress in cortical bone was more significantly related with the contact point of the mini-implant into the cortical bone surface than the insertion angle to the bone surface. The above results suggest that the maintenance of the mini-implant is more closely related with the diameter and contact point of the mini-implant into the cortical bone surface rather than the insertion angle.
Keywords
Stress distribution; Orthodontic mini-implant; Diameter; Insertion angle;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Umemori M, Sugawara J, Mitani H, Nagasaka H, Kawamura H. Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop 1999:115:166-74   DOI   ScienceOn
2 Costa A, Raffaini M, Melsen B. Miniscrew as orthodontic anchorage: A preliminary report. Int Adult Orthod Orthognath Surg 1998;13:201-9
3 정규림, 박영국, 이영준, 천훈. 구강내 고정원으로서 titanium miniscrew의 이용증례. 대치협회지 2000;38:1110-9
4 윤병수, 최병호, 이원유, 김경남, 심형보, 박진형. 성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구. 대치교정지 2001:31:517-23
5 Geng JP, Tan KB, Lui GR. Application of finite element analysis in implant dcntisity: a review of the literature. J Prosthet Dent 2001:85:585-98   DOI   ScienceOn
6 Mahler DB, Peyton FA. Photoelasticity as a research technique for analysing stresses in dental structures. J Dent Res 1955:34:831-8   DOI   ScienceOn
7 Pryputniewicz RJ, Burstone CJ. The effect of time and force magnitude on orthodontic tooth movement. J Dent Res 1979:58:1754-64   DOI   ScienceOn
8 Boresi P, Schmidt RJ. Advanced mechanics of materials. 5th ed. Cheshire: Sigma press: 1993. p. 584-7
9 Rohlmann A, Mossner D, Bergmann G, Kolbel R. Finite element analysis and experimental investigation in a femur with hip endoprosthesis. J Biomechanics. 1983;16:727-42   DOI   ScienceOn
10 박효상. Titanium microscrew implant를 이용한 skeletal cortical anchorage. 대치교정지 1999;29:699-706
11 임종원, 김왕식, 김일규, 손충렬, 변효인. 교정용 미니스크류 식립시 스크류의 길아. 직경 및 피질골 두께에 따른 응력분포에 관한 3차원 유한요소 법적 연구. 대치교정지 2003:33:11-20
12 Misch CE. 최신 임플란트 치과학. 2판. 서울: 나래 출판사; 2000. p. 311-49
13 김지혁, 주재용, 박영욱, 차봉근, 김성민. Skeletal anchorage system의 식립을 위한 한국인 악골의 피질골 두께에 관한 연구. 대구외과지 2002:28:249-55
14 Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuos loading of rigid endosseous implants. Am J Orthod 1984;86:95-111   DOI   ScienceOn
15 Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995:10:295-302
16 김종완, 장영일. 고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구. 대치교정지 2002:32:107-15
17 Freudenthaler JW, Hass R, Bantleon HP. Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clitical applications. Clin Oral Implants Res 2001;12:358-63   DOI   ScienceOn
18 경승현, 임중기, 박영철. Miniscrew를 고정원으로 이용한 교정치료. 대치교정지 2001:31:415-24
19 Yettram AL, Wright KW, Pickard HM. Finite element stress analysis of the crowns of normal and restored teeth. J Dent Res 1976:55:1004-11   DOI   ScienceOn
20 김재승, 성상진. 안정된 골고정원 확보. 치과 임상 2001: 6: 574-8
21 Wehrbein H, Merz BR, Diedrich P, Glatzmaier J. The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res 1996;7:410-6   DOI   ScienceOn
22 Stegaroiu R, Sato T, Kusakari H. Miyakowa O. Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis. Int J Oral Maxillofac Implants 1998:13:82-90
23 Melsen B, Petersen JK, Costa A. Zygoma ligatures: an alternative form of maxillary anchorage. J Clin Orthod 1998:32:154-8
24 Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997:31:763-7
25 Higuchi KW, Slack JM. The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement, Int J Oral Maxillofac Implants 1991;6:338-44
26 김재승, 성상진. 안정된 골고정원 확보. 치과 임상 2001:3:368-71
27 김재승, 성상진. 안정된 골고정원 확보. 치과 임상 2001: 5: 456-9
28 Proffit WR. Contemporary orthodontics. 3rd ed. St Louis: Mosby: 2000. p. 296-325
29 문철현. SAS의 임상적 적용과 실패의 원인 및 대책. 서울: 나래 출판사; 2002. p. 82-110
30 Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501