• Title/Summary/Keyword: 원자로노심

Search Result 251, Processing Time 0.027 seconds

Mechanical and Thermal Analysis of Oxide Fuel Rods

  • Ilsoon Hwang;Lee, Byungho;Lee, Changkun
    • Nuclear Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.223-236
    • /
    • 1977
  • An integral computer code has been developed for a mechanical and thermal design and performance analysis of an oxide fuel rod in a pressurized water reactor. The code designated as FROD 1.0 takes into account the phenomena of radial power depression within the pellet, cracking, densification and swelling of the pellet, fission gas release, clad creep, pellet-clad contact, heat transfer to coolant and buildup of corrosion layers on the clad surface. The FROD 1.0 code yields two-dimensional temperature distributions, dimensional changes, stresses, and internal pressure of a fuel rod as a function of irradiation time within a reasonable computation time. The code may also be used for the analyses of oxide fuel rods in other thermal reactors. As an application of FROD 1.0 the behavior of fuel rod loaded in the first core of Go-ri Nuclear Power Plant Unit 1 is predicted for the two power histories corresponding to steady state operation and Codition II of the ANS Classification. The results are compared with the design criteria described in the Final Safety Analysis Report and a discrepancy between these two values is discussed herein.

  • PDF

Heat balance analysis for process heat and hydrogen generation in VHTR (공정열 및 수소생산을 위한 초고온가스로 열평형 분석)

  • Park, Soyoung;Heo, Gyunyoung;Yoo, YeonJae;Lee, SangIL
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.85-92
    • /
    • 2016
  • Since the power density of the VHTR(Very High Temperature Reactor) is lower, there is less possibility of core melt. VHTR has no risk of explosion caused by hydrogen generation when the loss of coolant accident occurs, which is another advantage. Along with safety benefit, it can be used as a process heat supplier near demand facilities because coolant temperature is very high enough to be used for industrial purpose. In this paper, we designed the primary system using VHTR and the secondary system providing electricity and process heat. Based on that 350 MW thermal reactor proposed by NGNP(Next Generation Nuclear Part), we developed conceptual model that the IHX(Intermediate Heat Exchanger) loop transports 300 MW thermal energy to the secondary system. In addition, we analyzed thermodynamic behavior and performed the efficiency analysis and optimization study depending on major parameters.

An Application of Homogenization Theory to the Coarse-Mesh Nodal Calculation of PWRs (PWR 소격격자 Nodal 계산에의 균질화 이론 적용)

  • Myung Hyun Kim;Jonghwa Chang;Kap Suk Moon;Chang Kun Lee
    • Nuclear Engineering and Technology
    • /
    • v.16 no.4
    • /
    • pp.202-216
    • /
    • 1984
  • The success of coarse-mesh nodal solution methods provides strong motivation for finding homogenized parameters which, when used in global nodal calculation, will reproduce exactly all average nodal reaction rates for large nodes. Two approximate theories for finding these ideal parameters, namely, simplified equivalence theory and approximate node equivalence theory, are described herein and then applied to the PWR benchmark problem. Nodal code, ANM, is used for the global calculation as well as for the homogenization calculation. From the comparative analysis, it is recommended that homogenization be carried out only for the unique type of fuel assemblies and for core boundary color-sets. The use of approximate homogenized cross-sections and approximate discontinuity factors predicts nodal powers with maximum error of 0.8% and criticality within 0.1% error relative to the fine-mesh KIDD calculations.

  • PDF

Applicability of FDS for the Fire Hazard Analysis of the Fire Zone at Nuclear Power Plants (원전 화재방호구역의 화재위험 분석을 위한 FDS 적용성)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.13-18
    • /
    • 2006
  • The fire protection regulation for the nuclear power plants is based on the qualitative fire hazard assessment and the quantitative fire risk analysis, and the fire risk is managed by the fire protection plan with the appropriate balance among the fire prevention, fire suppression and the minimization of the fire effect. In these days, the zone model or the field model is generally used for the detail evaluation for the fire risk. At this paper, with consideration of the present trend, we evaluate whether the quantitative fire risk analysis and the assessment of fire result for fire areas at nuclear power plants can be possible by use of Fire Dynamics Simulator (FDS) that is the state-of-the-art fire modeling tool. Consequently, it is expected that the quantitative fire risk evaluation propelled by the fire modeling can be available as an applicable tool to improve the core damage frequency as well as the quantitative fire risk analysis.

A Response Time of the Nuclear Emergency Preparedness Robot based on the Gamma Ray Dose-Rate Constraints (감마선 선량율 제한조건에 따른 원자력 비상대응로봇의 대응시간)

  • Cho, JaiWan;Choi, Young Soo;Kim, TaeWon;Jeong, KyungMin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.807-810
    • /
    • 2014
  • 로봇 시스템의 제어 및 이를 이용한 환경 인식에는 많은 전자 광학 소자들이 사용되고 있다. 로봇 제어회로에 사용되고 있는 Si CMOS 공정의 CPU, ASIC, FPGA 소자는 고 선량의 감마선에 취약하다. 환경정보 수집용으로 로봇에 탑재되는 CMOS/CCD 카메라의 관측영상에는 고선량 감마선으로 인한 speckle (백색잡음, white noise) 들이 나타나며, 이들이 카메라의 관측성능을 저하시킨다. 후쿠시마 원자력발전소 사고와 같이 원자력시설에서 제어불능의 심각한 사고가 발생되면 고선량 감마선이 방출된다. 이러한 고선량 감마선방출은 사람에 의한 사고수습을 불가능하게 하며, 사고 수습을 위해서는 로봇의 활용이 불가피하다. 그러나, 방출되는 고선량 감마선의 세기(선량율)가 지나치게 높을 경우, 로봇 전자회로가 장애를 일으키기 때문에 로봇의 적절한 임무수행이 가능한 감마선 세기에 대한 고려가 필요하다. 본 논문에서는 고선량 감마선 환경하에서의 로봇 탑재 CCD/CMOS 카메라의 관측 성능을 고려하여 100 Gy/h 를 감마선 선량율 제한조건으로 설정한다. 그리고, 재 가동 승인심사를 받기 위해 일본의 원전 운영자들이 제시한 PWR (가압경수로) 원전의 중대사고 대책 적합성 평가문서에 나타난 노심용융개시 시점의 원자로 격납건물내 감마선 선량율 추이 계산결과를 활용하여 로봇의 대응시간을 계산하였다. 문서 (PDF) 에 표현된 감마선 선량율 추이 그래프를 영상 판독하여, 격납건물내 감마선 선량율이 100 Gy/h 제한조건에 도달하는 시간을 계산하였다. 이를 로봇의 대응시간으로 설정한다.

Application of Perturbation-based Sensitivity Analysis to Nuclear Characteristics (섭동론적 감도해석 이론의 원자로 핵특성에의 응용)

  • Byung Soo Lee;Mann Cho;Jeong Soo Han;Chung Hum Kim
    • Nuclear Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.78-84
    • /
    • 1986
  • An equation of material number density sensitivity coefficient is derived using first-order perturbation theory. The beginning of cycle of Super-Phenix I is taken as the reference system for this study. Effective multiplication factor of the reference system is defined as system response function and fuel enrichment and fuel effective density are chosen for the variation of reference input data since they are described by material number density which is a component of Boltzmann operator. The nuclear computational code system (KAERI-26 group cross section library/1DX/2DB/PERT-V) is employed for this calculation. Sensitivity coefficient of fuel enrichment on effective multiplication factor is 4.576 and sensitivity coefficient of effective fuel density on effective multiplication factor is 0.0756. This work shows that sensitivity methodology is lesser timeconsuming and gives more informations on important design parameters in comparison with the direct iterative calulation through large computer codes.

  • PDF

Thermal-Hydraulic Research Review and Cooperation Outcome for Light Water Reactor Fuel (경수로핵연료 열수력 연구개발 분석 및 연산학 협력 성과)

  • In, Wang Kee;Shin, Chang Hwan;Lee, Chi Young;Lee, Chan;Chun, Tae Hyun;Oh, Dong Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.815-824
    • /
    • 2016
  • The fuel assembly for pressurized water reactor (PWR) consists of fuel rod bundle, spacer grid and bottom/top end fittings. The cooling water in high pressure and temperature is introduced in lower plenum of reactor core and directed to upper plenum through the subchannel which is formed between the fuel rods. The main thermal-hydraulic performance parameters for the PWR fuel are pressure drop and critical heat flux in normal operating condition, and quenching time in accident condition. The Korea Atomic Energy Research Institute (KAERI) has been developing an advanced PWR fuel, dual-cooled annular fuel and accident tolerant fuel for the enhancement of fuel performance and the localization. For the key thermal-hydraulic technology development of PWR fuel, the KAERI LWR fuel team has conducted the experiments for pressure drop, turbulent flow mixing and heat transfer, critical heat flux(CHF) and quenching. The computational fluid dynamics (CFD) analysis was also performed to predict flow and heat transfer in fuel assembly including the spent fuel assembly in dry cask for interim repository. In addition, the research cooperation with university and nuclear fuel company was also carried out to develop a basic thermal-hydraulic technology and the commercialization.

Feasibility of Ultrasonic Inspection for Nuclear Grade Graphite (원자력급 흑연의 산화 정도에 따른 초음파특성 변화 및 초음파탐상의 타당성 연구)

  • Park, Jae-Seok;Yoon, Byung-Sik;Jang, Chang-Heui;Lee, Jong-Po
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.436-442
    • /
    • 2008
  • Graphite material has been recognized as a very competitive candidate for reflector, moderator, and structural material for very high temperature reactor (VHTR). Since VHTR is operated up to $900-950^{\circ}C$, small amount of impurity may accelerate the oxidation and degradation of carbon graphite, which results in increased porosity and lowered fracture toughness. In this study, ultrasonic wave propagation properties were investigated for both as-received and degradated material, and the feasibility of ultrasonic testing (UT) was estimated based on the result of ultrasonic property measurements. The ultrasonic properties of carbon graphite were half, more than 5 times, and 1/3 for velocity, attenuation, and signal-to-noise (S/N) ratio respectively. Degradation reduces the ultrasonic velocity slightly by 100 m/s, however the attenuation is about 2 times of as-receive state. The results of probability of detection (POD) estimation based on S/N ratio for side-drilled-hole (SDHs) of which depths were less than 100 mm were merely affected by oxidation and degradation. This result suggests that UT would be reliable method for nondestructive testing of carbon graphite material of which thickness is not over 100 mm. In accordance with the result produced by commercial automated ultrasonic testing (AUT) system, human error of ultrasonic testing is barely expected for the material of which thickness is not over 80 mm.

Development of Ultrasonic Waveguide Sensor for Under=Sodium Viewing in Liquid Metal Reactor (액체금속로 소듐내부 가시화를 위한 초음파 웨이브가이드 센서 개발)

  • Joo, Young-Sang;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.18-24
    • /
    • 2006
  • Reactor core and internal structures of a liquid metal reactor (LMR) can not be visually examined due to an opaque liquid sodium. The under-sodium viewing technique by using an ultrasonic wave should be applied far the visual inspection of reactor internals. In this study, an ultrasonic waveguide sensor with a strip plate has been developed for an application to the under-sodium viewing technique. The Lamb wave propagation of a waveguide sensor has been analyzed and the zero-order antisymmetric $A_0$ plate wave was selected as the application mode of the sensor. The $A_0$ plate wave can be propagated in the dispersive low frequency range by using a liquid wedge clamped to the waveguide. A new technique is presented which is capable of steering the radiation beam angle of a waveguide sensor without a mechanical movement of the sensor assembly The steering function of the ultrasonic radiation beam can be achieved by a frequency tuning method of the excitation pulse in the dispersive range of the $A_0$ mode. The technique provides an opportunity to overcome the scanning limitation of a waveguide sensor. The beam steering function has been evaluated by an experimental verification. The ultrasonic C-scanning experiments are performed in water and the feasibility of the ultrasonic waveguide sensor has been verified.

Analysis of Loss of Offsite Power Transient Using RELAP5/MODl/NSC; I: KNU1 Plant Transient Simulation (RELA5/MOD1/NSC를 이용한 원자력 1호기 외부전원상실사고해석 - I. 실제사고해석)

  • Kim, Hho-Jung;Chung, Bub-Dong;Lee, Young-Jin;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.97-106
    • /
    • 1986
  • System thermal-hydraulic parameters and simulated, using the best-estimate system code(RELAPS/MODl/NSC), based upon the sequence of events for the KNU1 (Korea Nuclear Unit 1) loss of offsite power transient at 77.5% power which occurred on June 9,1981. The results are compared with the actual plant transient data and show good agreements. After the flow coastdown following the trips of both reactor coolant pumps, the establishment of natural circulation by the temperature difference between the hot and the cold legs is confirmed. The calculated reactor coolant flowrate closely approximates the plant data indicating the validity of relevant thermal-hydraulic models in the RELAP5/MOD1/NSC. Results also show that the sufficient heat removal capability is secured by the appropriate supply of the auxiliary feedwater without the operation of S/G PORVs. In addition, a scenario accident at full power, based upon the same sequence of events described above, is also analysed and the results confirmed that the safety of KNU1 is secured by the appropriate operation of the S/G PORVs coupled with the supply of auxiliary feedwater which ensures sufficient heat removal capability. The characteristics of the non-safety related components such as the turbine stop valve closing time, S/G PORV settings etc. are recognized to be important in the transient analyses on a bestestimate basis.

  • PDF