• Title/Summary/Keyword: 원관유동

Search Result 70, Processing Time 0.024 seconds

Large Eddy Simulation of Turbulent Pipe Flow (LES에 의한 원관 내 난류의 유동 해석)

  • 고상철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.437-446
    • /
    • 2003
  • A large eddy simulation (LES) is performed for turbulent pipe flow. The simulation code is constructed by using a general coordinate system based on the physical contravariant velocity components. The effects of grid fineness which can be well prediction of turbulent behavior in near wall region is investigated. The subgrid scale turbulent models are applied and validated emphasis is placed on the flow details of turbulent pipe flow The calculated Reynolds number is 360 based on the wall shear velocity and the inlet pipe diameter. The predicted turbulent statistics are evaluated by comparing with the DNS data of turbulent pipe flow Performed by Eggels et al. The agreement of LES with DNS data is shown to be satisfactory. The proper grid fineness of the well prediction of turbulent pipe flow is suggested and the turbulent behavior is analyzed by depict the contour plot of fluctuating velocity components.

Structure of turbulence of fully developed flow in concentric annuli with rough outer wall (거친외벽면을 가진 동심환형관내에서 완전히 발달된 유동의 난류구조)

  • Ahn, S.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • For roughened annular pipes with diameter ratios of 0.26, 0.39, and 0.56 and with Reynolds numbers ranging 13,000 to 67,000, friction factor, autocorrelation coefficients, power spectral density functions, and integral length scales for each flow condition using X-type hot wire anemometry system are experimentally investigated. Distributions of these quantities show that the times which the streamwise autocorrelation coefficients become zero first increase with decreasing the radius ratios of concentric annuli and Reynolds numbers, however the power spectra density functions increase with increasing the radius ratios and Reynolds number.

  • PDF

A Study on the Enhanced Heat Transfer and Fluid Flow Induced by Square-Ribbed Surface Roughness (4각 리브로된 표면조도에 의한 유체유동 및 열전달 증진에 관한 연구)

  • Lee, C.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.155-162
    • /
    • 1992
  • Theoritical Study is performed on heat transfer and fluid flow induced by square-ribbed roughness elements in a concentric annulus. The fluid properties were assumed to be constant, and the radius($r_m$) of the maximum speed point was found by using the principle of equation of Leung and Labib. The Nusselt number and friction factor as a function of the Reynolds number($R_e=10^4$, $5{\times}10^4$, $7{\times}10^4$, $10^5$) in artifical roughness $S/{\epsilon}=5,10,20,30$, $P/{\epsilon}=2,5,8$ and prandtl number = 0.72 have been discussed. In this study, it has been found that the Nusselt number and friction factor of rough wall are larger than those of smooth ones.

  • PDF

PIV Measurement on Ice Slurry Pipe Flow (PIV에 의한 원관내 Ice Slurry의 유동계측)

  • Doh Deog Hee;Kim Dong Hyuk;Oh Cheol;Hong Seong Dae;Park Seong Ryong;Hwang Tae Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2005
  • Experimental studies on the characteristics of ice slurry flows in a circular pipe is rare due to the deficiency of conventional measurement techniques. In this report the flow characteristics are quantitatively investigated by the use of PIV technique concerning the Ice Packing Factor(IPF) and the power changes of pump motor It was experimentally verified that the power loss does not increase any more at a certain IPF value.

Effects of Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Upward Two-Phase Flow (수직상향 이상류에서 동심원관 간극이 유동양식과 보이드분포에 미치는 영향)

  • Son B. J.;Kim I. S.;Kim M. C.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.4
    • /
    • pp.383-391
    • /
    • 1987
  • An experimental investigation has been conducted to determine the flow pattern for two-component , two-phase mixtures which flow vertically upwards in concentric annuli based on the measurement for the local void fraction and the distribution of the local void fraction in various radial locations in the annular gap. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel rod, The rod diameter is either :2mm,16mm or 20mm. It is demonstrated that the probability density function of the fluctuations in void fraction may be used as an flow pattern indicator and the local void fraction distribution depends on the flow pattern and radial location in the annular passage.

  • PDF

Numerical Simulation of Flows inside a Photocatalysis Air Cleaning System for Performance Assessment (광촉매 공기청정 시스템 성능예측을 위한 시스템 내부 유동현상에 관한 수치모사)

  • Sohn, Deok-Young;Lee, Du-Hwan;Gill, Jae-Heung;Choi, Yun-Ho;Kim, Dong-Hyun
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.141-149
    • /
    • 2002
  • In the present study, flow fields inside a photocatalysis air cleaning system have been investigated to obtain the data for optimum design of the system. For this investigation, we first predicted the pressure drop of a photocatalysis filter. Based on this calculation, we replaced the filter by the porous media and analysed the performance of the entire system. This porous media assumption could predict characteristics of the cylindrical photocatalysis filter within 1%. Two cases of the cylindrical filter were considered in the present calculations. The first case had an inside diameter of 6 mm, while the second case had an inside diameter of 20 mm. It was found that the first case of filter showed a pressure drop three times higher than that of the second case. In addition, the cylindrical filter equipped with a housing to hold a number of cylinders in a bundle was also analyzed. When the housing was present, the pressure drop increased. It was found that the pressure drop is 8 times higher than that of the case when the housing was not equipped.

  • PDF

Turbulent Couette Flow between Coaxial Cylinders with Inner Cylinder Rotating (내측원관이 회전하는 동심이중원관 사이의 난류 쿠에트 유동에 관한 연구)

  • 김광용;김진욱;조용철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.540-546
    • /
    • 1992
  • Turbulent Couette flow between coaxial cylinders with inner one rotating has been investigated experimentally and numerically. The radius ratio of the coaxial cylinders is 0.43. Mean velocity and turbulent stresses have been measured by hot-wire anemometer in the range of Reynolds number based on the velocity at rotating wall and the radial distance between walls, 60,900-187,000. For the numerical computation, the Reynolds stress model has been used as a turbulence closure model. Measurements of mean velocity show that the velocity profile of wall layer largely deviates from universal logarithmic law due to the effect of streamline curvature, especially in the region near the stationary outer cylinder. The results computed with the Reynolds stress model agree well with the experimental data in the prediction of circumferential intensity of turbulent fluctuations. However, the computed level of radial intensity is much higher than the measurement. Curvature-corrected versions of the Reynolds stress model improves the prediction of turbulent intensities, but the results are not fully satisfactory.

Experimental Study of Natural Convection for Magnetic Fluids in Annular Pipes Under the Influence of External Magnetic Fields (이중원관내 자성유체의 외부자장에 대한 자연대류의 실험적 연구)

  • 서이수;박정우;이준희
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.6
    • /
    • pp.245-249
    • /
    • 2001
  • Natural convection of a magnetic fluid is different from that of Newtonian fluids because magnetic body force exists in an addition to gravity and buoyancy. In this paper, natural convection of a magnetic fluids (W-40) in annular pipes was studied by experimentally. Inside wall was kept at a constant temperature (25 $^{\circ}C$), and outside wall was also held at a constant but lower temperature (20 $^{\circ}C$). The magnetic fields of various magnitude were applied up. This study has resulted in the following fact that the natural convection of a magnetic fluids was controlled by the direction and intensity of the magnetic fields.

  • PDF

The Effect of Surrounding Gas Flow on the Heat Transfer of the Falling Film Flowing Down the Outside of a Vertical Tube (수직원관 외부 유하액막 열전달에 주변 기체유동이 미치는 영향)

  • 권경민;정시영;김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.996-1003
    • /
    • 2002
  • Heat transfer characteristics were investigated for the falling film flowing down the outside of an electrically heated vertical tube. Water was used for the falling film, and its Reynolds number was varied in the range of 70~500. Because water is heated and evaporated as it flows down, both sensible and latent heat transfer should be considered. The effect of the surrounding air movement was investigated by changing the direction of the air injection; without air injection, parallel-flow, and counter-flow. For all cases, sensible teat transfer rate was almost linearly increased with the increasing film flow rate. It was found that the film heat transfer coefficient was hardly influenced by the parallel air flow. However, the counter-flow of air reduced the heat transfer coefficient, which might be caused by the uneven distribution or flooding of the film. At high heat flux, a sudden change of the film heat transfer coefficient was detected as the film flow rate reached the transition value. It is supposed that this phenomenon was caused by the change in the film flow pattern.

A Study on Flow Characteristics with Ultrasonic Forcing in a Coaxial Circular Pipe by PIV Measurement (동심원관내에서 초음파가 가진된 유동특성의 PIV계측에 의한 연구)

  • Koo, J.H.;Park, Y.H.;Choi, W.C.;Song, M.G.;Ju, E.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.639-644
    • /
    • 2000
  • An experiment on the enhancement of turbulent flow with ultrasonic forcing was carried out by using PIV measurement in a coaxial circular pipe which could offer characteristics of the turbulence flow plentifully through its jet. A large transparent acryl tank and a coaxial circular pipe nozzle were made for the above research. city water of $25^{\circ}C$ was selected as an experimental liquid and the front flow field of the coaxial circular pipe was divided vertically as 3 measuring regions to observe characteristics of flow phenomena. characteristics of fluid flow such as velocity vector distribution, kinetic energy, turbulent intensity and etc. were visualized, observed, examined and considered at 5 kinds of Re No. such as $Re=1{\times}10^3,\;2{\times}10^3,\;3{\times}10^3,\;5{\times}10^3,\;1{\times}10^4$. In result it was proved that ultrasonic vibration affected the enhancement of turbulent flow.

  • PDF