• Title/Summary/Keyword: 원격주사 검사

Search Result 13, Processing Time 0.033 seconds

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

A Study on the Development of a Target Tracing Equipment by Remote Control for a Medical Theraphy and Diagnosis of an Ophthalmology (안과 진단 및 치료기기의 원격조정 표적 추적장치 개발에 관한 연구)

  • Eo, Y.K.;Park, H.C.;Lee, S.R.;Yang, Y.S.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.29-32
    • /
    • 1996
  • 기존의 안과 진단 및 치료 기기의 안구 고정장치는 진단 및 치료에 있어서 피검사자와 검사자에 사이에 충분한 협조가 되지 않을 경우 진단의 비효율성과 치료의 안정성등의 문제가 발생하고있다. 따라서 이러한 문제를 보완하기 위하여 SLO의 전면 세극등을 소형의 반사경으로 대치하고 표시등을 후면의 먼거리에 수직으로 배열시켜서 피검사자에게 적당한 높이의 고정등을 선택하게하여 수직방향의 안구 위치를 고정시키고 SLO(Scanning Laser Ophthalmoscope)의 좌우 회전기능으로 표적의 수평방향을 근절시킨 후에 검사자의 조작으로 원격조정되는 서보장치를 이용하여 다시 반사경을 전방향으로 미세하게 회전되게하여 정확한 위치로 안구를 이동시키게 하는 원격조정 표적 추적장치를 개발하였다. 이에 따라 피검사자는 거울에 비친 먼거리의 허상을 보게 되어 세극등을 이용한 근접주사방식의 단점인 안구의 축동, 폭주등으로 인한 환자의 눈의 피로를 최소화하면서 피검사자의 안구를 검사자가 원하는 위치로 고정시킬 수 있게 함으로써 임상실험에서 안과 진단의 정확성과 관리도를 높이고 치료의 효율성과 안전성을 증가시킬 수 있는 원격조정 추적장치로써의 성능을 확인하였다.

  • PDF

Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline (배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.95-102
    • /
    • 2005
  • There are many tube and pipeline in nuclear power plant under high temperature and high pressure. Erosion and corrosion defects were expected on these tube and pipe-line by environmental and mechanical factors. These erosion and corrosion defects ran be evaluated by ultrasonic technique. In these study, Scanning Laser Source(SLS) technique was applied to detect defect and construct image. This technique also makes detection possible on rough and curved surfaces such as tube and pipe-line by scanning. Conventional ultrasonic scanning technique requires immersion of specimen or water jet for transferring ultrasonic wave between transducer and specimen. However, this SLS technique does not need contacting and couplant to generate surface wave and to get flaw images. Therefore, this SLS technique has several advantages, for complicated production inspection, non-contact, remote from specimen, and high resolution. In this study, SLS images were obtained with various conditions of generation laser ultrasound and receiving in order to enhance detectability of flaws on the tube. Stress corrosion cracks were produced on tube and images of stress corrosion cracks were constructed by using SLS technique.

A study on the strategies to lower technologist occupational exposure according to the performance form in PET scan procedure (PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구)

  • Ko, Hyun Soo;Kim, Ho Sung;Nam-Kung, Chang Kyeoung;Yoon, Soon Sang;Song, Jae Hyuk;Ryu, Jae Kwang;Jung, Woo Young;Chang, Jung Chan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.17-29
    • /
    • 2015
  • Purpose For nuclear medicine technologists, it is difficult to stay away from or to separate from radiation sources comparing with workers who are using radiation generating devices. Nuclear medicine technologists work is recognized as an optimized way when they are familiar with work practices. The aims of this study are to measure radiation exposure of technologists working in PET and to evaluate the occupational radiation dose after implementation of strategies to lower exposure. Materials and Methods We divided into four working types by QC for PET, injection, scan and etc. in PET scan procedure. In QC of PET, we compared the radiation exposure controlling next to $^{68}Ge$ cylinder phantom directly to controlling the table in console room remotely. In injection, we compared the radiation exposure guiding patient in waiting room before injection to after injection. In scan procedure of PET, we compared the radiation exposure moving the table using the control button located next to the patient to moving the table using the control button located in the far distance. PERSONAL ELECTRONIC DOSEMETER (PED), Tracerco$^{TM}$ was used for measuring exposed radiation doses. Results The average doses of exposed radiation were $0.27{\pm}0.04{\mu}Sv$ when controlling the table directly and $0.13{\pm}0.14{\mu}Sv$ when controlling the table remotely while performing QC. The average doses of exposed radiation were $0.97{\pm}0.36{\mu}Sv$ when guiding patient after injection and $0.62{\pm}0.17{\mu}Sv$ when guiding patient before injection. The average doses of exposed radiation were $1.33{\pm}0.54{\mu}Sv$ when using the control button located next to the patient and $0.94{\pm}0.50{\mu}Sv$ when using the control button located in far distance while acquiring image. As a result, there were statistically significant differences(P<0.05). Conclusion: From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine. Conclusion From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine.

  • PDF

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

A Customized Cancer Radiation Treatment Planning Simulation (ccRTPs) System via Web and Network (웹과 네트워크 기술을 이용한 환자 맞춤식 암치료 계획 시뮬레이션 시스템)

  • Khm, O-Yeon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.144-152
    • /
    • 2006
  • The telemedicine using independent client-server system via networks can provide high quality normalized services to many hospitals, specifically to local/rural area hospitals. This will eventually lead to a decreased medical cost because the centralized institute can handle big computer hardware systems and complicated software systems efficiently and economically, Customized cancer radiation treatment planning for each patient Is very useful for both a patient and a doctor because it makes possible for the most effective treatment with the least possible dose to patient. Radiation planners know that too small a dose to the tumor can result in recurrence of the cancer, while too large a dose to healthy tissue can cause complications or even death. The best solution is to build an accurate planning simulation system to provide better treatment strategies based on each patient's computerized tomography (CT) image. We are developing a web-based and a network-based customized cancer radiation therapy simulation system consisting of four Important computer codes; a CT managing code for preparing the patients target data from their CT image files, a parallel Monte Carlo high-energy beam code (PMCEPT code) for calculating doses against the target generated from the patient CT image, a parallel linear programming code for optimizing the treatment plan, and scientific data visualization code for efficient pre/post evaluation of the results. The whole softwares will run on a high performance Beowulf PC cluster of about 100-200 CPUs. Efficient management of the hardware and software systems is not an easy task for a hospital. Therefore, we integrated our system into the client-sewer system via network or web and provide high quality normalized services to many hospitals. Seamless communication with doctors is maintained via messenger function of the server-client system.

  • PDF

A Case of Lung Cancer with Metastasis to the Right Fifth Toe (제 5 우족지의 전이를 동반한 폐암 1예)

  • Lee, Hong-Lyeol;Kim, Se-Kyu;Lee, Hwan-Mo;Shin, Dong-Hwan;Chang, Jung-Hyun;Kwak, Seung-Min;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.72-78
    • /
    • 1993
  • Background: In malignancies, detection of metastatic foci is of value in making therapeutic plans for treatment of disease and prevention of life-threatening complications. Common sites for metastasis of bronchogenic cancer include lymph nodes, liver, brain, adrenals and bone. Skull, vertebrae, ribs and long bones are common sites for bone metastasis. But in epidermoid carcinoma, the incidence of bone metastasis is relatively low and especially to the distal phalangeal bone is rare. Methods: We experienced a case of epidermoid carcinoma with the first distant metastasis to the fifth distal phalangeal bone, right toe. Results: The initial stage in the diagnosis of epidermoid carcinoma was T4N3MO. During the third round of anticancer chemotherapy, we recognized the distant metastasis to the fifth distal phalangeal bone for the first time. Localized abnormal findings were noted by bone X-ray and scanning. By a histopathologic examination of the amputated toe, we confirmed the metastasis of epidrmoid bronchogenic carcinoma. Conclusion: If localized abnormal finding is discovered at an unusual site for metastasis, we recommend physicians to consider the possibility of metastasis even though it is very low.

  • PDF

A Case of Locally Recurrent Gastric Cancer at Kim's Tie Site of the Jejunum after a Total Gastrectomy (위전절제술 후 Kim 's Tie 부근 공장에 국소 재발한 위암환자 1예)

  • Bae Byung-Gu;Suh Byoung-Jo;Yu Hang-Jong;Kang Yun-Kyung;Kim Jin-Pok
    • Journal of Gastric Cancer
    • /
    • v.5 no.1
    • /
    • pp.52-56
    • /
    • 2005
  • Despite improvements in the surgical treatment of gastric adenocarcinomas, the recurrence rates remain high in patients with advanced-stage disease. Most of the recurrence occurs within 3 years of the surgical resection, and nearly $90\%$ of the patients with recurrence die within 2 years of the diagnosis of recurrence. A recent study analyzed recurrence patterns for patients who had undergone a potentially curative gastrectomy. For those patients, $33\%$ of the recurrences involved locoregional sites, $44\%$ the peritoneum, and $38\%$ distant sites. A 51-year-old female patient was diagnosed with stomach cancer and underwent a total gastrectomy with D2 lymph node dissection during Oct. 1999. The pathologic report indicated a T3N1M0 tumor. We performed immunochemotherapy for 2 years with regular follow up. A gastrofiberscopic examination done during sep. 2004, cancer recurrence was found at the Kim's tie site of the jejunual loop. We did an abdominal exploration and a segmental resection of cancer site with pathologically negative resection margins. After the operation, we started secondary chemotherapy with TS-1.

  • PDF

The Consideration of nuclear medicine technologist's occupational dose from patient who are undergoing 18F-FDG Whole body PET/CT : Aspect of specific characteristic of patient and contact time with patient (18F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰: 환자 고유특성 및 응대시간 측면)

  • Kim, Sunghwan;Ryu, Jaekwang;Ko, Hyunsoo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.67-75
    • /
    • 2018
  • Purpose The purpose of this study is to investigate and analyze the external dose rates of $^{18}F-FDG$ Whole Body PET/CT patients by distance, and to identify the main factors that contribute to the reduction of radiation dose by checking the cumulative doses of nuclear medicine technologist(NMT). Materials and Methods After completion of the $^{18}F-FDG$ Whole Body PET/CT scan($75.4{\pm}3.3min$), the external dose rates of 106 patients were measured at a distance of 0, 10, 30, 50, and 100 cm from the chest. Gender, age, BMI(Body Mass Index), fasting time, diabetes mellitus, radiopharmaceutical injection information, creatine value were collected to analyze individual factors that could affect external dose rates from a patient's perspective. From the perspective of NMT, personal pocket dosimeters were worn on the chest to record accumulated dose of NMT who performed the injection task($T_1$, $T_2$ and $T_3$) and scan task($T_4$, $T_5$ and $T_6$). In addition, patient contact time with NMT was measured and analyzed. Results External dose rates from the patient for each distance were calculated as $246.9{\pm}37.6$, $129.9{\pm}16.7$, $61.2{\pm}9.1$, $34.4{\pm}5.9$, and $13.1{\pm}2.4{\mu}Sv/hr$ respectively. On the patient's aspect, there was a significant difference in the proximity of gender, BMI, Injection dose and creatine value, but the difference decreased as the distance increased. In case of dialysis patient, external dose rates for each distance were exceptionally higher than other patients. On the NMT aspect, the doses received from patients were 0.70, 1.09, $0.55{\mu}Sv/person$ for performing the injection task($T_1$, $T_2$, and $T_3$), and were 1.25, 0.82, $1.23{\mu}Sv/person$ for performing the scan task($T_4$, $T_5$, $T_6$). Conclusion we found that maintaining proper distance with patient and reducing contact time with patient had a significant effect on accumulated doses. Considering those points, efforts such as sufficient water intake and encourage of urination, maintaining the proper distance between the NMT and the patient(at least 100 cm), and reducing the contact time should be done for reducing dose rates not only patient but also NMT.

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.