• 제목/요약/키워드: 운전 pH

검색결과 325건 처리시간 0.025초

Corrosion Control in Water Distribution System using Lime and Carbon Dioxide(I) - Determination of Optimum Operational Conditions in Lime Adding Process (소석회와 CO2를 이용한 상수관로의 부식제어(I) - 소석회 주입공정의 최적 운전인자 도출)

  • Sohn, Byung-Young;Byun, Kyu-Sik;Kim, Young-Il;Lee, Doo-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제22권3호
    • /
    • pp.373-378
    • /
    • 2008
  • The pH & alkalinity adjustment method by lime and carbon dioxide($CO_2$) for corrosion control in water distribution system was investigated to determine the optimum operational condition in lime adding process in water treatment plant(WTP). The mixing time at dissolution tank and sedimentation time at saturator for maintaining optimal turbidity condition of lime supernatant were 60~75 minutes and 75~95 minutes, respectively. There was no difference according to $CO_2$ adding methods such as $CO_2$ saturated water or $CO_2$ gas. But, $CO_2$ saturated water could be convenience at WTP in terms of pH control and quantitative dosing. To minimize generation of calcium carbonate products, the short time interval between adding of lime and $CO_2$ is most important. The lime should be added below 32 mg/l for preventing pH rising and generation of calcium carbonate products at the heating condition.

Pressure Drop of Integrated Hybrid System and Microbe-population Distribution of Biofilter-media (통합 하이브리드시스템의 압력강하 거동 및 바이오필터 담체의 미생물 population 분포)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.116-124
    • /
    • 2022
  • In this study, waste air containing ethanol and hydrogen sulfide, was treated by an integrated hybrid system composed of two alternatively-operating UV/photocatalytic reactor-process and biofilter processes of a biofilter system having two units with an improved design (R reactor) and a conventional biofilter (L reactor). Both a pressure drop (△p) per unit process of the integrated hybrid system and a microbe-population-distribution of each biofilter process were observed. The △p of the UV/photocatalytic reactor process turned out very negligible. The △p of the L reactor was observed to increase continuously to 4.0~5.0 mmH2O (i.e., 5.0~6.25 mmH2O/m). In case of R reactor, its △p showed the one below ca. 16~20% of the △p of the L reactor. Adopting such microbes-carrying biofilter media with high porosity as waste-tire crumb media, and the improved biofilter design, contributed to △p of this study, reduced by ca. 37~50% and 40~53%, respectively, from the reported △p of conventional biofilter packed with biofilter media of the mixture (50:50) of wood chip and wood bark. In addition, the △p of R reactor in this study, reduced by ca. 80% from the reported △p of conventional biofilter packed with biofilter media of the mixture (75:25) of scoria with high porosity and compost, was mainly attributed to adopting the improved biofilter design. On the other hand, in case of L reactor, the CFU counts in its lowest column was analyzed double as much as those in any other columns. However, in case of R reactor, its CFU counts were bigger by 50% than the one of L reactor and its microbes were evenly distributed at its higher and lower columns of Rdn reactor and Rup reactor. This phenomena was attributed to an even moisture distribution of 50~55% of R reactor at its higher and lower columns. Therefore, R reactor showed superb characteristics in terms of both △p and microbe-population-distribution, compared to L reactor.

A Study on the Cleanup of Diesel-Contaminated Soil by Micro-Bubble Soil Washing Process (미세기포를 이용한 토양세척기법의 디젤 오염토양 정화에 관한 연구)

  • 조장환;정민정;민경석;최상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 1999년도 정기총회 및 춘계 공동 학술발표회
    • /
    • pp.97-99
    • /
    • 1999
  • 본 연구에서는 디젤로 오염된 토양을 효율적으로 정화하기 위해, 알칼리제와 과산화수소를 이용하는 새로운 방식의 토양세척기법에 대하여 일련의 회분식 실험을 통하여 최적의 운전조건을 검토하고자 하였다. 알칼리제인 NaOH를 이용하여 세척수의 pH를 상승시켜, 강알칼리 상태에서 과산화수소를 주입하면 미세기포가 발생되며, 이 미세기포에 의해 토양에 흡착되어 있는 유류 오염물질이 효과적으로 탈착.부상된다. #60(0.25mm) 이하의 자연토양을 6,500 mg TPH/kg dry soil로 오염시켜 사용하였으며, 세척수의 pH, 진탕비(토양 중량 : 세척용액 부피), 과산화수소 주입량, 세척시간에 의한 영향을 살펴보았다. 세척수의 pH는 12, 진탕비는 1:5, 과산화수소 주입량은 1%, 세척시간은 1시간으로 적용한 결과 최대효율(60%)을 얻을 수 있었다.

  • PDF

Effect of pH on Growth and Ethanol Production of Clostridium ljungdahlii (Clostridium ljungdahlii 성장 및 에탄올 생산에 pH가 미치는 영향)

  • Park, So Jung;Hong, Sung-Gu;Kang, Kwon-Kyoo;Kim, Young-Kee
    • Applied Chemistry for Engineering
    • /
    • 제22권5호
    • /
    • pp.562-565
    • /
    • 2011
  • In this study, we developed a bioprocess using Clostridium ljungdahlii as a biological catalyst to produce bio-ethanol, and the effect of pH on microbial growth and ethanol production was investigated. From the results of fermentation at various initial pH condition without pH control, pH of fermentation broth decreased to 4.5 within 24 h due to accumulation of by-product acetic acid and both microbial growth and ethanol production were stopped. The experimental result of initial pH 8 showed the highest microbial growth and ethanol production (0.53 g/L), since the pH drop was relatively slow. From the experiment of pH 7 maintained fermentation using pH controllable bioreactor, the maximum cell dry weight of 1.65 g/L and the maximum ethanol concentration of 1.43 g/L were obtained within 24 h. In conclusion, the C. ljungdahlii growth was enhanced by pH maintenance of neutral range, and the ethanol production was also enhanced based on the growth-associated ethanol production characteristics of C. ljungdahlii.

Tests on the Reactive Power Limit and the OEL Dynamics of Yang-Yang P/P in Operation (양양 양수 발전기의 계통 운전시 무효전력 운전범위와 OEL 동특성 시험)

  • Kim, D.J.;Moon, Y.H.;Han, J.R.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.384-386
    • /
    • 2006
  • This paper deals with tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of generation unit. The suggested reactive limit test methods can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state operation condition. The on-line OEL limit test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to Yang-Yang Pumped storage units of 282 MVA.

  • PDF

Continuous Production of Authentic Human Growth Hormone from Methionyl Human Growth Hormone Using the Column Reactor of Immobilized Aminopeptidase M (고정화 Aminopeptidase M 컬럼 반응기를 이용한 메치오닐 인간성장호르몬으로부터 천연형 인간성장호르몬의 연속생산)

  • 이성희;김기태
    • KSBB Journal
    • /
    • 제10권3호
    • /
    • pp.283-291
    • /
    • 1995
  • The characteristics of aminopeptidase M(ApM) immobilized covalently on Cellufine Formyl and the continuous production of authentic human growth hormone(hGH) from methionyl human growth hormono(met-hGH) using the column reactor packed with immobilized ApM were investigated. Immobilized ApM with the proportion of 2.3mg ApM per 1g Cellufine Formyl gel had the highest met-hGH conversion activity. The optimum pH(7.0) and temperature($55^{\circ}C$) showed no appreciable difference between free and immobilized enzymes and the optimum temperature in continuous operation of the column reactor was also found to be $55^{\circ}C$. Under the conditions at which met-hGH was converted completely to hGH, the yield and productivity were about 77% and 0.8mg hGH/ml$.$h, respectively. In two column reactors of different sizes, met-hGH was converted to hGH with the same conversion rates and hGH yields at the same space velocities. The half-life of the reactor systems at $45^{\circ}C$ and $55^{\circ}C$ were projected from the continuous operations for 90 days to be 225 days and 81 days, respectively.

  • PDF

Efficiency Characteristics by Mixed Absorbents for the Removal of Odor Compounds in the Wet Scrubber (습식세정탑 내 악취가스 제거를 위한 복합흡수제의 효율 특성)

  • Park, Young G.;Kim, Jeong-in
    • Applied Chemistry for Engineering
    • /
    • 제22권1호
    • /
    • pp.48-55
    • /
    • 2011
  • It was found that the absorbent mixed with 2-aminoethanol and others has been applied to remove them via chemical neutralization. The absorbent of natural second metabolites was achieved by a removal efficiency of 20~30% by itself depending on treatment conditions, but the complex absorbent mixed with 0.2% amine chemical provides the removal efficiency of over 98%. Optimal removal efficiencies have been examined against two major parameters of the temperature and pH to remove ammonia and hydrogen sulfide gases. The chemical analysis was also performed to analyze the composition of an essential oil by GC-MS. The monoterpenes in an essential oil reacted with odorous compounds by neutralization and their reaction mechanism was partially elucidated.

Evaluation of Coagulation-UF Process Considering Residual Aluminuim Concentration as Seawater Desalination Pretreatment (해수담수화 전처리 공정으로써 잔류 알루미늄 농도를 고려한 응집-UF 공정 연구)

  • Son, Dong-Min;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제35권7호
    • /
    • pp.495-502
    • /
    • 2013
  • This work was performed to investigate proper condition of coagulation treatment as UF process pretreatment that consider UF permeate flux and residual Al concentration. The coagulant used an alum as $Al_2(SO_4)_3{\cdot}16H_2O$ and PACl (r = 1.5) made this study. The experiment was tested in adjusting conditions such as alum dose, flocculation time and coagulation pH of seawater. Consequently, higher coagulant dose lead to elevation of UF permeate flux while residual aluminium also increased in condition of pH 8.0. The most suitable condition which has a good permeate flux and low residual aluminium, in this works, was coagulant dose of 0.7 mg/L (as Al, alum) and 1.2 mg/L (as Al, PACl) and coagulation pH 6.5. In addition, applying the flocculation time with 1.2 mg/L of PACI reduced. The flocculation time reduced UF permeate flux in using alum.

Buffer Intensity of Ammonia and MPA in Water-Steam Cycle of PWRs (가압경수로 원전 물-증기 순환영역에서 암모니아와 MPA의 완충세기)

  • Rhee, In-H.;Ahn, Hyun-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제11권7호
    • /
    • pp.2708-2712
    • /
    • 2010
  • Amines, ammonia or 3-methoxypropylamine (MPA), are used to maintain the optimized pH for the prevention of corrosion in the secondary side of Pressurized Water Reactors (PWRs). They are differently dissociated as a function of temperature which is not same in each location of the water-steam cycle. pH at the operation temperature depends on temperature of fluid and equilibrium constants of water and amines. Thus, every amine provides the different pH in the entire secondary side so that pH is not only the sufficient parameter in corrosion control. The secondary parameter, i.e., buffer intensity, is the ability to maintain a stable pH when $H^+$ are added or removed due to the ingress of impurities or the reaction of corrosion. The buffer intensity is necessary to provide the selection criteria for the best pH control agent for secondary side and the basic understanding of the reason why the flow-accelerated corrosion(FAC) rate may demonstrate the bell-shape curve over temperature. The buffer intensities of ammonia and MPA were reviewed over the entire operation temperature of PWRs. The sufficient buffer intensity is provided for the inhibition of corrosion by ammonia in low temperature $(25{\sim}100^{\circ}C)$ and by DMA in high temperature $(150{\sim}250^{\circ}C)$. In terms of buffer intensity, i) the best pH control agent is an amine with $pK_a(T)$ range of pH(T)- $1{\leq}pK_a(T){\leq}pH(T)$ + 0.5 and ii) the amine solution should have sufficient buffer intensity, ${\beta}$ to inhibit corrosion, and iii) FAC rate may be maximum at the temperature, where ${\beta}_B/{\beta}$ ratio is lowest.

Performance Evaluation and Characteristic Study of the Single Anaerobic Digestion from Piggery Slurry (돈분 슬러리를 이용한 단상 혐기소화공정의 특성연구 및 성능평가)

  • Park, Woo-Kyun;Jun, Hang-Bae;Park, Noh-Back;Kwon, Soon-Ik;Shin, Joung-Du;Hong, Seung-Gil
    • Korean Journal of Environmental Agriculture
    • /
    • 제30권1호
    • /
    • pp.31-36
    • /
    • 2011
  • BACKGROUND: Disposal of slurry animal manure produced by an anaerobic slurry-type barn method is not easy since the animal slurry contain high moisture content which makes solid-liquid separation a difficult process. However, recently, the interest about anaerobic digestion process as an environment-friendly waste disposal method has gained a wide interest because it can treat highly organic matter contained by the piggery slurry, decrease the odor after treatment, and enable the effective recovery of the methane gas which is a valuable energy resource. The objectives of this study were to identify the solubilization characteristics and to improve the anaerobic digestion efficiency of piggery slurry through full-scale anaerobic digestion experiments. METHODS AND RESULTS: In a full-scale continuous anaerobic digestion operation, the adaptability of single anaerobic digestion and its digestion efficiency were also evaluated in the farm field. The actual pH range and alkalinity concentration of piggery slurry used during the operation were comparatively higher than the concentrations of pH and alkalinity in the digestion tank which were stable at 7.5~8.0, 4,008 mg/L (as$CaCO_3$), respectively. The removal efficiency of organic matter (TCOD) by anaerobic digestion was 75~90% and methane gas production amount was at 0.33 L/L/day, a little higher than that of ordinary animal manure. CONCLUSION(s): Our findings showed higher recovery of highly purified methane and greater efficiency of anaerobic tank digestion since its methane gas content was at 65~70%.