• Title/Summary/Keyword: 운전 시뮬레이션

Search Result 782, Processing Time 0.023 seconds

Phase Current Variation of Bifilar-Wound Hybrid Stepping Motor by Lead Angle Control (Lead Angle 제어에 의한 복권형 하이브리드 스테핑 전동기의 상전류 변화에 관한 연구)

  • 우광준;이종언
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.26-34
    • /
    • 1998
  • In this paper, we confirm that the instanteneous phase current of the bifilar-wound hybrid stepping motor is dependent of lead angle by the experimental results. The variation of phase current with lead angle gives informations about the rotor position at the moment when phase winding coil is excited. We show that the rotor position of the bifilar-wound hybrid stepping motor for the closed-loop drives can be detected by using the instantaneous phase current measurement. We propose an instantaneous phase current equation as the function of electrical lead angle by the modeling of the bifilar-wound hybrid stepping motor. We also analyze the relationship between instantaneous phase current and rotor position by the computer simulation results. By the experimental results, we also confirm that the information about the rotor position can be obtained from the instantaneous phase current values at the instance of $\pi/2$ electrical angle of excitation pulse. pulse.

  • PDF

Sensorless Vector Control Using Tabu Search Algorithm (타부 탐색을 이용한 센서리스 벡터 제어)

  • Lee, Yang-Woo;Park, Kyung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2625-2632
    • /
    • 2009
  • Recently, a speed control method of induction motor by vector control theory is applied to highly efficient industrial field. The speed sensors attached to motor are used for detection of rotating speed. In the case using speed sensor, the installation of cable for minimization of electric noise, weaken maintenance, increase of price are demerit. Therefore the study of speed sensorless vector control theory performed activity. The design of sensorless vector controller for induction motor using tabu search is studied. The proposed sensorless vector control for Induction Motor is composed of two parts. The first part is for optimizing the speed estimation with initial PI parameters. The second part is for optimizing the speed control with initial PI parameters using tabu search. Proposed tabu search is improved by neighbor solution creation using Triangular random distribution. In order to show the usefulness of the proposed method, we apply the proposed controller to the sensorless speed control of an actual AC induction Motor System. The performance of this approach is verified through simulation and the experiment.

A Study on the Optimal Method for Malfunction of Protection Devices in Distribution Systems Interconnected with Photovoltaic Systems (태양광발전이 연계된 배전계통에서 보호협조기기의 오동작에 대한 최적 방안에 관한 연구)

  • Rho, Dae-Seok;Kim, Chan-Hyeok;Shin, Chang-Hoon;Jeong, Won-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1599-1606
    • /
    • 2008
  • Recently, new dispersed generation systems such as photovoltaic, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy with the provision against oil crisis. The technical guidelines on the interconnection of dispersed generation systems have been established and conducted positively. However, protection devices (Re-closer) in primary feeder of distribution system interconnected with photovoltaic generation may cause problems with mis-operation, and then many customers could have problems like an interruption. So, this paper presents the optimal method to minimize the impact of interruption, using both the symmetric method and MATLAB/SIMULINK. And, also this paper shows the effectiveness of proposed method by simulating at the real distribution systems.

Implementation of a Hybrid Controller for Hydraulic Inverter Controller (유압식 인버터 제어기를 위한 하이브리드 제어기 구현)

  • 한권상;최병욱
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.55-64
    • /
    • 2002
  • Due to the friction characteristics of cylinders and the rail of a passenger car, in the system actuated with hydraulic systems, there exist dead zones, which can not be controlled by a PID controller. In this paper, the friction characteristics of a cylinder is examined, which may cause the abrupt increase of the acceleration in the zero-crossing speed region. To overcome the drawbacks of a PID controlled hydraulic system, a zooming fuzzy logic controller is designed and finally an improved hybrid controller is Proposed. The proposed controller is composed of the PID controller and the zooming fuzzy controller. The effectiveness of the proposed control scheme is shown by simulation and experimental results, In which the proposed hybrid control method yields good control performance not only in the zero-crossing speed region but also In the overall control region including steady-state region.

A Novel Fault Detection Method of Open-Fault in NPC Inverter System (NPC 인버터의 개방성 고장에 대한 새로운 고장 검출 방법)

  • Lee, Jae-Chul;Kim, Tae-Jin;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • In this paper, a novel fault detection method for fault tolerant control is proposed when the NPC inverter has a open failure in the switching device. The open fault of switching device is detected by checking the variation of a leg-voltage in the neutral-point-clamped inverter and the two phases control method is used for continuously balance the three phases voltage to the load. It can be achieve the fault tolerant control for improving the reliability of the NPC inverter by the fault detection and reconfiguration. This method has fast detection ability and a simple realization for fault detection, compared with a conventional method. Also, this fast detection ability improved the harmful effects such as DC-link voltage unbalance and overstress to other switching devices from a delay of fault detection. The proposed method has been verified by simulation and experiment.

Development of Hardware Simulator for DFIG Wind Power System Composed of Anemometer and Motor-Generator Set (풍속계와 Motor-Generator 세트를 이용한 DFIG 풍력발전시스템 하드웨어 시뮬레이터 개발)

  • Oh, Seung-Jin;Cha, Min-Young;Kim, Jong-Won;Jeong, Jong-Kyou;Han, Byung-Moon;Chang, Byung-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.11-19
    • /
    • 2011
  • This paper describe development of a hardware simulator for the DFIG wind power system, which was designed considering wind characteristic, blade characteristic, and blade inertia compensation. The simulator consists of three major parts, such as wind turbine model using induction motor, doubly-fed induction generator, converter-inverter set. and control system. The turbine simulator generates torque and speed signals for a specific wind turbine with respect to the given wind speed which is detected by Anemometer. This torque and speed signals are scaled down to fit the input of 3.5kW DFIG. The MSC operates to track the maximum power point, and the GSC controls the active and reactive power supplied to the grid. The operational feasibility was verified through computer simulations with PSCAD/EMTDC. And the implementation feasibility was confirmed through experimental works with a hardware set-up.

A Single-Phase Quasi Z-Source AC-AC Converter with a Series Connection of the Output Terminals (출력이 직렬 결합된 단상 Quasi Z-소스 AC-AC 컨버터)

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.415-429
    • /
    • 2011
  • In this study, a single-phase quasi Z-source AC-AC converters with a series connection of the output terminals is proposed. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel and its output terminals are connected in series. The out of phase mode and in phase mode of the proposed system are presented. To verify the validity of the proposed converter, a DSP controlled hardware was made and PSIM simulation was executed. As a result, controlling the duty ratio of the converter, the desired buck-boost output voltages could be generated. For each modes, as compared with the single converter operation, the proposed converter could enhance the efficiency and input power factor according to different loads. Also, in case of the out of phase mode under the constant load, the efficiency and input power factor of the proposed system are increased 10[%], 35[%] respectively in compared with the single converter. And, the output voltage is constantly controlled in dynamic state in case while the load is suddenly changed.

Fault Modeling and Diagnosis using Wavelet Decomposition in Squirrel-Cage Induction Motor Under Mixed Fault Condition (복합고장을 가지는 농형유도전동기의 모델링과 웨이블릿 분해를 이용한 고장진단)

  • Kim, Youn-Tae;Bae, Hyeon;Park, Jin-Su;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.6
    • /
    • pp.691-697
    • /
    • 2006
  • Induction motors are critical components in industrial process. So there are many research in the condition based maintenance, online monitoring system, and fault detection. This paper presents a scheme on the detection and diagnosis of the three-phase squirrel induction motor under unbalanced voltage, broken rotor bar, and a combination of these two faults. Actually one fault happen in operation, it influence other component in motor or cause another faults. Accordingly it is useful to diagnose and detect a combination fault in induction motor as well as each fault. The proposed fault detection and diagnosis algorithm is based on the stator currents from the squirrel induction motor and simulated with the aid of Matlab Simulink.

Design of High Performance Hybrid Fuzzy Controller for the zero-crossing speed control of a Hydraulic System (유압시스템의 극저속 속도제어를 위한 하이브리드 퍼지 제어기의 설계)

  • Han, Sang-Soo;Kim, Chan-Seob;Son, Seong-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2352-2360
    • /
    • 2007
  • Due to the friction characteristics of cylinders and the rail of a passenger car, in the elevator actuated with hydraulic systems, there exist dead zones, which can not be controlled by a PID controller. In this paper, the friction characteristics of a cylinder is examined, which may cause the abrupt increase of the acceleration in the zero-costing speed region. To overcome the drawbacks of a PID controlled hydraulic elevator system, a zooming fuzzy logic controller is designed and finally an improved hybrid fuzzy controller is proposed. The effectiveness of the proposed control scheme are shown by simulation and experimental results, which the proposed fuzzy hybrid control method yields good control performance not only in the zero-crossing speed region but also in the overall control region including steady-state region.

A Study on Water Balance in Stationary Load Proton Exchange Membrane(PEM) Fuel Cell Power Generator (고정 부하를 갖는 PEM 연료전지 발전기에 있어서의 수분 평형에 관한 연구)

  • Bakhtiar, Agung;Oh, Hoo-Kyu;Yoon, Jung-In;Kim, Young-Bok;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.128-135
    • /
    • 2011
  • 일반적으로 PEM 연료전지에서는 수분 균형이 시스템의 효율에 결정적으로 영향을 미치기 때문에, 이에 대한 균형(balance)을 잡는 것이 매우 중요하다. 특히, 촉매 층에서 물이 넘치는 익수현상(flooding)이나 건조현상(drying)이 발생하게 되면 연료전지의 효율이 급격하게 저하하므로, 항상 수분의 균형이 잡히도록 시스템을 제어하는 것이 일반적이다. 이 때,수분의 익수현상이나 건조현상은 PEM 연료전지의 용량과 주위의 환경, 즉 온도와 습도에 많은 영향을 받게 된다. 금번 논문에서는 가정용 규모인 3kW급에서 10kW급까지의 PEM 연료전지를 설치하였을 때, 주위의 환경(온도와 습도)이 수분 이동에 어떠한 영향을 미치는 지를 시간에 따라서 시뮬레이션(simulation)한 결과를 보여주고 있다. 결과에서 유입공기의 온도가 $50^{\circ}C$ 이하일 경우, 고정부하가 5kW급 이하이면 대부분이 건조현상이 발생하였으나, 고정부하가 6kW급 이상이 되면 익수현상이 운전시간이 20분 이내에서 발생하였다. 또한 고정부하를 최고 10kW급까지 올린 경우, 유입공기의 온도가 $50^{\circ}C$까지는 익수현상이 발생하였으나 $60^{\circ}C$ 이상인 경우에는 거의 건조현상이 발생함을 알 수 있었다.