• Title/Summary/Keyword: 운동 검출

Search Result 204, Processing Time 0.021 seconds

A Study on the Measurement of Tissue Blood Flow by the Self-Mixing Effect of Laser Diode (레이저 다이오드의 자기혼합 효과를 이용한 조직혈류 측정에 관한 연구)

  • Ko, Ran-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 1994
  • This paper describes the measurement of tissue blood flow by the the self-mixing effect of laser diode. A Laser doppler signals due to the moving object and the tissue blood flow were detected by the self-mixing effect of laser diode. The Doppler shifted frequency was changed linearly with the driving frequency of moving object and was increase after the exercise. The results of in-vivo experiment were consistent with the result of exercise physiology.

  • PDF

Measurement by Essential Tremor through Interaction between the Image Projector, Camera and Laser Pointer (프로젝터 영상과 레이저 포인터의 상호작용을 통한 손 떨림 정도 측정 기법)

  • Park, Jung-Joo;Lee, Jae-Ha;Park, Jong-Il
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.347-348
    • /
    • 2016
  • 프로젝터와 레이저 포인터를 이용한 상호작용은 널리 알려져 있다. 상호작용을 통해 레이저가 쓰기 동작을 하는 것처럼 보이게 함으로써 프레젠테이션에 활용하거나 마우스 기능을 대신하여 사용자와 영상간의 상호작용을 수행하였다. 본 논문은 위의 연구를 확장하여 스크린 영상에서 레이저를 실시간 검출하여 떨림 정도를 측정하는 방안을 제안한다. 제안된 방법은 레이저 광점이 찍힌 스크린 영상을 카메라로 다시 입력 받는 과정에서 레이저를 정확하게 검출하고 이를 통해 기준점 대비 실험자의 손 떨림의 정도를 수치화 하여, 손 떨림을 검출하고자 할 때 사용되었던 기존 방법인 자세 떨림(postural tremor)이나 운동 떨림(kinetic tremor)과 같은 직관적 관찰에 비해 떨림의 정도를 효과적으로 나타낼 수 있다.

  • PDF

Development of Monitoring System for the weak and the elderly (노약자 활동상황 감시를 위한 시스템의 개발)

  • Kang, Dong-Youn;Yun, Hee-Hak;Park, Chan-Sik;Cha, En-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.93-94
    • /
    • 2007
  • 노약자 활동상황 감시에서 활동정보와 위치정보는 매우 중요하다. 본 논문에서는 3축 가속도센서와 ZigBee 통신을 이용하여 노약자 활동상황 감시를 위한 시스템을 개발하였다. 가속도센서로부터 활동량을 측정하고 운동량을 계산하기 위한 걸음 검출을 하며, ZigBee 통신을 이용하여 감시시스템으로 전송하여 실시간으로 노약자의 활동상황을 모니터링 할 수 있다. 추가로 부착위치에 강인한 걸음 검출 알고리즘을 제안하였으며, 실제 실험을 통해 가속도센서를 가슴에 부착할 경우 99.83%의 정확도로 걸음을 검출할 수 있음을 확인하였다. 또한 ZigBee 통신의 수신신호세기를 이용하여 노약자가 있는 방을 구별할 수 있었다.

  • PDF

Development of Insole Type Capacitive Pressure Sensor for Smart Gait Analysis (스마트 보행분석을 위한 깔창 형태의 전기용량성 압력센서 개발)

  • Woo, Hyunsoo;Min, Se Dong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.411-412
    • /
    • 2012
  • 본 논문에서는 인간의 가장 기본적이며 기초적인 운동인 걸음걸이로부터 검출할 수 있는 걸음 수 및 보행분석을 위해 전도성 섬유를 이용한 전기용량성압력 센서를 깔창형태로 개발하였다. 개발된 깔창 형태의 센서는 보행시의 압력을 측정하여 보행신호를 검출하고, 검출된 신호를 이용하여 걸음 수 및 보행 분석을 실시하였다. 개발된 센서의 성능 검증을 위하여 상용 만보계 및 관찰자의 수계로 도출된 보수를 비교하였으며, 자세에 따른 압력차이를 측정하였다. 기존의 상용 만보계는 저속(1 Km/h)으로 걸었을 때 보수가 잘 측정되지 않은 반면 개발된 센서는 저속에서도 관찰자 수계대비 정확한 보수를 도출 할 수 있었다. 또한 자세에 따라 압력 값을 토대로 사용자의 자세를 모니터링 할 수 있음을 보였다. 본 연구는 향후 스마트폰과 무선 연동하는 스마트 보행관리 시스템을 개발하기 위한 기초연구이다.

  • PDF

Active Spinning Training System using Complex Physiological Signals (복합 생체신호를 이용한 능동형 스피닝 트레이닝 시스템)

  • Kim, Cheol-Min;Kang, Gyeong-Heon;Kim, Eun-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.591-600
    • /
    • 2015
  • Recently high interest in health and fitness has led to vibrant researches for the active fitness system to learn and enjoy the exercise program for oneself. In this paper, we design and implement the active spinning training system which enables user to have self-learning and experience of customized spinning training program by the biometric and movement information acquired from user's physiological signals. The proposed system provides the appropriate difficulty of spinning program which reflects the concordance rate of spinning dance gestures and the amount of exercising by analyzing the physical status of participant from his brain and pulse waves and recognizing the skeletal movement in real time. For the higher exercise effect, the system offers a virtual personal trainer to show the correct poses and controls the level of difficulty depending on the concordance rate of participant's motions. The experiment with various participants through the proposed system shows that it is able to help users in getting the available exercise effect in comparatively short time.

Optimization of Design Variables of Detection Algorithm for Loss of Balance Using a Linear Internal Model (균형상실의 검출 성능 향상을 위한 내부 모델의 설계변수 선정 및 민감도 평가)

  • Kim, Kwang-Hoon;Kim, In-Su;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1153-1160
    • /
    • 2010
  • The detection algorithm for loss of balance had three main parts: one for processing data, another for constructing an internal model, and a third for detecting the loss of balance. The part related to the internal model is the most important part of the algorithm. The purpose of this study is to evaluate the effect of variables associated with the internal model on the success rate of the algorithm. The internal model depends on the type of linearization adopted and the operating period of the algorithm. The design variables were evaluated by performing sensitivity analysis of the variables of the internal model in order to obtain the success rate of the algorithm. The results showed that the most sensitive variable was the period and the period of 0.3 s yielded the highest success rate of 97.1%. Further, the ranges of the design variables that can facilitate a success rate of over 95% are presented.

Analysis of Motional Characteristics of Sperm Using Image Processing (영상처리를 이용한 정자의 운동 특성 분석)

  • Shim, Hoon-Sup;Yi, Won-Jin;Park, Kwang-Suk;Paick, Jae-Seung
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.11
    • /
    • pp.109-115
    • /
    • 1994
  • In this paper, we developed an analyzing method of the motional characteristics of sperm, using image processing technology. Without the aid of a dedicated image-processor, this processing of a personal computer(PC) and a simple image processing board. The image processing board is used for acquiring images from a microscopic imaging source. The PC processes the images from the board and computes the parameters of motional characteristics of sperms. The algorithm of the site detection of sperms and the 'Match Matrix Method' is noteworthy. After comparing the results of our method with those of the manual method, and with those of the method using a dedicated image-processor, we concluded that our method is useful and reliable.

  • PDF

Quantitative Analysis for the Effect of Sensory Information on the Motor (감각정보의 차이가 운동에 미치는 영향에 대한 정량적 분석)

  • 홍철운;심해영;박찬희;김남균
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.165-170
    • /
    • 2002
  • The aim of this study was to analyze the effect of different sensory information on the motor function which is resulted from visual stimuli. Particularly, it was focused on the effect of complementary color stimuli on reaction time. Twenty volunteers(10 men & 10 women), between the age of 20 and 25 yearn participated in this experiment. Experiments were carried out in a light & sound-attenuated chamber, and the overall system consisted of a PC. interface card. LEDs. key board switch, and display panel. Although many measurements of sensory-motor integration has been studied the quantitative analysis of sensory-motor integration has not been developed well. Quantitative analyses were performed to investigate the effect of the different sensory information on the arm motor system in the point of view sensory-motor integration. The result showed that the reaction time for visual stimuli of complementary colors was faster than that under same color environments : and, in same color environments and the reaction speed was varied inversely with respect to the magnitude of the light wavelength.

Real-Time Object Tracking Algorithm based on Minimal Contour in Surveillance Networks (서베일런스 네트워크에서 최소 윤곽을 기초로 하는 실시간 객체 추적 알고리즘)

  • Kang, Sung-Kwan;Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.12 no.8
    • /
    • pp.337-343
    • /
    • 2014
  • This paper proposes a minimal contour tracking algorithm that reduces transmission of data for tracking mobile objects in surveillance networks in terms of detection and communication load. This algorithm perform detection for object tracking and when it transmit image data to server from camera, it minimized communication load by reducing quantity of transmission data. This algorithm use minimal tracking area based on the kinematics of the object. The modeling of object's kinematics allows for pruning out part of the tracking area that cannot be mechanically visited by the mobile object within scheduled time. In applications to detect an object in real time,when transmitting a large amount of image data it is possible to reduce the transmission load.

Technical Note: Development of Wireless Electrooculorgraphy System to Measure Vestibuloocular Reflex (단신: 전정 반사 분석을 위한 안구 움직임 무선 측정 장치 개발)

  • Park, Yang-Sun;Kim, Hyung-Sik;Yi, Jeong-Han;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • The purpose of this study was to develop EOG system for collecting eye movement patterns to investigate visual function and position and the level of balancing. This small and partable wireless EOG system was enabled to collect stable signals without hindering any kind of sports movement. This system was consist of four parts: amplifier, main process with wireless transmitter, receiver, and display. Three EOG electrodes were used and placed on right(+), left(-) sides of eyes, and between eyes as a reference. This system was possible to measure signals for relatively long duration but the degeneration of electrodes may magnify measurement errors when collecting time was getting longer. Thus, dry electrodes may be applied to the system when long term measurement is needed for future studies.