• Title/Summary/Keyword: 운동오차측정

Search Result 148, Processing Time 0.031 seconds

A study on bio-signal process for prosthesis arm control (인공의수의 능동 제어를 위한 생체 신호 처리에 관한 연구)

  • Ahn, Young-Myung;Yoo, Jae-Myung
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.28-36
    • /
    • 2006
  • In this paper, an algorithm to classify the 4 motions of arm and a control system to position control the prosthesis are studied. To classify the 4 motions, we use flex sensors which is electrical resistance type sensor that can measure warp of muscle. The flex sensors are attached to the biceps brchii muscle and coracobrachialis muscle and the sensor signals are passed the sensing system. 4 motion of the forearm - flexion and extension, the pronation and supination are classified from this. Also position of forearm is measured from the classified signals. Finally, A two D.O.F prosthesis arm with RC servo-motor is designed to verify the validity of the algorithm. At this time, fuzzy controller is used to reduce the position error by rotary inertia and noise. From the experiment, the position error had occurred within about 5 degree.

High Precision Measurement of Rotational Accuracy (회전정밀도의 고정밀 측정기술)

  • Wei Gao
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.7-13
    • /
    • 2004
  • 초정밀 공작기계의 기능은 초정밀 운동에 의해 대부분 지배된다. 이러한 운동을 생성하는 고정밀 베어링의 운동정밀도는 이미 나노미터 레벨에 도달하고 있으며, 이러한 운동정밀도를 나노미터 레벨의 정밀도로 측정하는 것(정밀나노계측)이 중요한 과제가 되고 있다. 예를 들어, 초정밀선반 등에 있어서, 공기베어링을 대표로 하는 높은 회전정밀도를 갖는 회전축(주축)이 사용되고 있으며, 따라서 이러한 고정밀 주축의 회전정밀도를 나노미터 레벨의 정밀도로 평가하는 기술은 매우 중요하다. (중략)

A Study on Improvement of Wave Height Algorithm using Accelerometer (가속도계를 이용한 파고 알고리즘 개선에 관한 연구)

  • Chung, Dong-Keun;Lim, Myung-Jae;Lee, Joon-Taik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.215-220
    • /
    • 2014
  • Most of studies on wave height algorithms that are using at buoys describe algorithms using double integral to determine the position data from the acceleration data measured from the accelerometer. but sometimes, it can involve some cumulative error in that process, and result in misjudgment or unstabe system. On the other hand, It is widely known that the motion of fluid particles on or underneath a linear progressive wave is periodic and elliptic. This fact is considered in this article and leads a improved algorithms with no integral processing.

The Study on the location-based realtime measurement system for the road surface using Laser Displacement Sensor and GPS (레이저 변위센서와 GPS를 이용한 위치기반 실시간 도로표면 측정 시스템에 관한 연구)

  • Hwang, Seon-Deok;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2351-2353
    • /
    • 2005
  • 본 논문은 포장도로의 표면 상태를 고성능의 레이저 변위 센서를 사용하여 정밀하게 측정하고, GPS(Global Positioning System)를 사용하여 측정 위치 데이터를 획득하는 도로 표면 측정 장비 개발에 관한 논문이다. 본 연구에서는 전체 시스템을 설계하고, 차량 주행을 모사한 실험 모형을 제작하여 실내 실험을 실시하였으며, GPS 단말기로부터 실시간으로 위치 신호를 수신하여 도로면 데이터와 연동할 수 있도록 하였다. 그리고 평가 차량의 전면에 레일(rail)을 장착하여 레이저 변위 센서가 좌우로 왕복운동이 가능하도록 하였으며, 레일을 작동시킨 상태에서 도로면을 측정해 보았다. 실험 모형의 측정 곁과는 차량이 80km/h로 주행할 때 도로 표지 타이닝(tinning)의 폭 오차 3.24%, 깊이 오차 5%였다. 차량이 정지된 상태에서 레일을 작동시켜 요철을 측정하였을 경우 레일 방향에 대한 폭 오차는 0.07%였다.

  • PDF

Synthesis of an On-Line 5 Degrees of Freedom Error Measurement System for Translational Motion Rigid Bodies (병진운동 강체의 온라인 5자유도 운동오차 측정시스템 설계 및 해석)

  • 김진상;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.93-99
    • /
    • 1998
  • Although laser interferometer measurement system has advantages of measurement range and accuracy, it has some disadvantages when measurement of multi degrees of freedom of motion are required. Because the traditional error measurement methods for geometric errors (two straightness and three angular errors) of a slide of machine tools measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric errors of a moving rigid body in real time processes, an on-line error measurement system for simultaneous detection of the five error components of a moving object is required. Using laser alignment technique and some optoelectronic components, an on-line measurement system with 5 degrees of freedom was developed for the geometric error detection in this study Performance verification of the system has been performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a slide of machine tools.

  • PDF

Measuring of Linear Motion Accuracy of NC Lathe using Linear Scales (리니어 스케일을 이용한 NC 선반의 직선 운동정도 측정)

  • 김영석;김재열;한지희;정정표;윤원주;송인석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1243-1248
    • /
    • 2003
  • It is very important to measure linear motion accuracy of NC lathe as it affects all other parts of machines machined by them in industries. If the motion accuracy of NC lathe is bad, the dimension accuracy and the change-ability of works will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear motion of ATC(Automatic tool changer) on zx plane of NC lathe using two linear scales and the time pulses coming out from computer in order to get data at constant time intervals from the linear scales. And each sets of error data obtained from the test is discripted to plots and the results of linear motion errors are expressed as numerics by computer treatment.

  • PDF

Developement of Measuring Units of circular Motion Accuracy on NC Lathe (NC선반의 원 운동정도 측정장치의 개발)

  • 김영석;김재열
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2001
  • It is very important to test circular motion accuracy of NC machine tools as it affects all other machines machined by them in industries. In this paper, it has become possible to detect errors of linear displacement of radial directions for circle tar motion accuracy test using newly assembled magnetic type of linear scale so called Magnescale ball-bar system. It has also organized computer program systems using tick pulses come out from computer for getting error motion data at colt start time interval in circular motion test on NC lathe. Error data gotten from test is expressed to plots and analysed to numerics by various statistical treatments.

  • PDF

Control of an Artificial Arm using Flex Sensor Signal (굽힘 센서신호를 이용한 인공의수의 제어)

  • Yoo, Jae-Myung;Kim, Young-Tark
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.6
    • /
    • pp.738-743
    • /
    • 2007
  • In this paper, a muscle motion sensing system and an artificial arm control system are studied. The artificial arm is for the people who lost one's forearm. The muscle motion sensing system detect the intention of motion from the upper arm's muscle. In sensing system we use flex sensors which is electrical resistance type sensor. The sensor is attached on the biceps brachii muscle and coracobrachialis muscle of the upper arm. We propose an algorithm to classify the one's intention of motions from the sensor signal. Using this algorithm, we extract the 4 motions which are flexion and extension of the forearm, pronation and supination of the arm. To verify the validity of the proposed algorithms we made experiments with two d.o.f. artificial arm. To reduce the control errors of the artificial arm we also proposed a fuzzy PID control algorithm which based on the errors and error rate.

Development of Attitude Heading Reference System based on MEMS for High Speed Autonomous Underwater Vehicle (고속 자율 무인잠수정 적용을 위한 MEMS 기술기반 자세 측정 장치 개발)

  • Hwang, A-Rom;Ahn, Nam-Hyun;Yoon, Seon-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.666-673
    • /
    • 2013
  • This paper proposes the performance evaluation test of attitude heading reference system (AHRS) suitable for small high speed autonomous underwater vehicle(AUV). Although IMU can provides the detail attitude information, it is sometime not suitable for small AUV with short operation time in view of price and the electrical power consumption. One of alternative for tactical grade IMU is the AHRS based micro-machined electro mechanical system(MEMS) which can overcome many problems that have inhibited the adoption of inertial system for small AUV such as cost and power consumption. A cost effective and small size AHRS which incorporates measurements from 3-axis MEMS gyroscopes, accelerometers, and 3-axis magnetometers has been developed to provide a complete attitude solution for AUV and the attitude calculation algorithm is derived based the coordinate transform equation and Kalman filter. The developed AHRS was validated through various performance tests as like the magnetometer calibration, operating experiments using land mobile vehicle and flight motion simulator (FMS). The test of magnetometer calibration shows the developed MEMS AHRS is robust to the external magent field change and the test with land vehicle proves the leveling error of developed MEMS AHRS is below $0.5^{\circ}/hr$. The results of FMS test shows the fact that AHRS provides the measurement with $0.5^{\circ}/hr$ error during 5 minutes operation time. These results of performance evaluation tests showed that the developed AHRS provides attitude information which error of roll and pitch are below $1^{\circ}$ and the error of yaw is below $5^{\circ}$ and satisfies the required specification. It is expected that developed AHRS can provide the precise attitude measurement under sea trial with real AUV.

Design and Implementation of Kalman-filter Based User Movement Distance Algorithm Suitable for Domestic Environment (국내 환경에 적합한 Kalman-filter 기반 사용자 운동거리 측정 알고리즘 설계 및 구현)

  • Jang, Young-Hwan;Im, Subong;Park, Seok-Cheon;Lee, Bong-Gyou;Lee, Sang-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1624-1630
    • /
    • 2019
  • With the increase in there are smart devices penetration around the world, services related to exercise checks are attracting attention. However, there is existing exercise amount measurement service does not use the altitude information, or because the use of an algorithm that does not corrected the GPS altitude error is not accurate movement distance provided have a problem. Therefore, in this paper, to improve the existing problems, Kalman-filter-based user movement distance measurement algorithm is designed and implementation of improved by using the Kalman-filter based GPS and barometric altimeter sensor fusion algorithm to improve the altitude value the accuracy and of calculate the coordinate plane distance. As a result of comparing the designed and implementation of algorithm with the existing algorithms, it is confirmed that the proposed algorithm improves the accuracy by about 2.17%.