• Title/Summary/Keyword: 용접형강 부재

Search Result 17, Processing Time 0.028 seconds

The Development of the Direct Strength Method for Welded Steel Members (용접형강의 직접강도법 개발에 관한 연구 고찰)

  • Ryu, Seung Wan;Park, Sung Woong;Kwon, Young Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.231-241
    • /
    • 2015
  • The direct strength method (DSM) has been adopted by the NAS (2004) and AS/NZS 4600 (2005) for the design of cold-formed steel members. The method can be successfully applied to the design of welded steel members. This paper reviews the development of the DSM for welded steel structural members. The design strength formulae for welded section columns and beams for the DSM are based on the test results performed on welded H-section, C-section, circular and rectangular hollow section columns, plate girders and stiffened plates. The comparison between the design strength of welded sections predicted by the DSM and that estimated by existing specifications is also provided. The comparison verifies that the DSM can properly predict the compressive, flexural and shear strength of welded section columns and beams with the interaction between local and overall buckling.

The Weld Strength and Design Tables for the Unstiffened Seated Connections (비보강받침접합의 용접강도와 설계도표)

  • Choi, Sun-Kyu;Yoo, Jung-Han;Lee, Kang-Min;Park, Jai-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.2
    • /
    • pp.199-206
    • /
    • 2012
  • Unstiffened seated connections (USC) ensure easy installation and safety during erection, thereby making the process more economical. USCs consist of a seat angle for carrying the beam's reactions and a top angle to provide beam stability. These angles are bolted or welded to the beam and supporting member. This paper sought to propose a design table for the weld strength of such connections obtained from the elastic vector method (EVM) and the instantaneous center-of-rotation method (ICM) in terms of calculating the eccentricity. Also, the proposed design table is compared with both AISC and KBC specifications.

Welding Characteristics of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 용접특성)

  • Kim, Hee-Dong;Yang, Jae-Geun;Lee, Eun-Taik;Kim, Woo-Bum;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.129-136
    • /
    • 2012
  • This study seeks to evaluate the welding characteristics of SHN400 steel, which is suitable for the steel material used in building structures in KS. For this purpose, the Y-groove weld crack test and hardness, tensile, bending, cross tensile, and charpy V notch tests at the welding point were conducted with specimens taken from the highest, the thickest and the commonly used H-beams for girder or beam members. Each test was conducted under the KS test conditions. All tests results satisfied the requirements of KS and the welding requirements for the proper inelastic behavior of structure, indicating that SHN400 can be used for the building structure as a structural material.

Self-Optimizing Structural Design of a Pre-engineered Building System with Nonprismatic Members based on AISC2005 (AISC2005에 기준한 변단면 선설계 건축물시스템의 자동화 최적구조설계)

  • Kim, Yong Seok;Oh, Myoung Ho;Song, Byung Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.193-201
    • /
    • 2009
  • Structural design of most nonprismatic Pre-Engineered Building Systems (PEBS) is performed using optimizing software developed in foreign countries. In this study, a structural optimizing software for the design of 3-D structures of nonprismatic PEBS is developed according to the allowable stress design method of AISC2005 and KBC. Optimizing structural design with nonprismatic members is carried out by repeating the process of structural analysis and member design to minimize the weight of a structure. According to the optimizing design results of 2-D and 3-D structures with nonprismatic members, there are considerable steel savings in designing structures with nonprismatic H-shaped built-up sections rather than with H-shaped rolled sections. When H-shaped built-up sections were used, the weight of the structural steel was reduced when AISC2005 specification rather than AISC1898 was used in the design. It is therefore concluded that utilizing the new AISC2005 specification is safer in preventingweb buckling because the height of a member is designed to be small despite some differences depending on the structural type.

Material Properties of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 소재 특성)

  • Kim, Hee-Dong;Choi, Byoung-Jeong;Kim, Sang-Sub;Kim, Chul-Hwan;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.515-522
    • /
    • 2011
  • The purpose of this study was to evaluate the material characteristics of SHN400 steel, which is suitable as a steel material for building structures, using the experimental approach. For this purpose, the chemical composition test, tensile test, macro test, micro test, and charpy notch impact test were conducted with specimens taken from the highest, thickest, and commonly used H-beams for girder or beam members. Each test was conducted under the Korean Standard(KS) test conditions. All the test results satisfied the requirements of KS (KS D 3866) and the steel material for seismic design. The carbon equivalent value (Ceq), which is related to weldability, and the yield ratio, which is related to inelastic behavior, showed especially good results. Thus, SHN400 is definitely suitable as the steel material for building structures.

An Experimental Study on the Fire Resistance Capacity of Asymmetric Slimflor Beam (비대칭 H형강 슬림플로어 보의 내화 성능에 관한 실험적 연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Asymmetric Slimflor Beam had been unveiled with Thor beam (Hat beam) in Sweden since the late 1970s and had been developed by British Steen and SCI. In the major advanced countries in Europe after the early 1990s have interested in and developed this method, it has been concrened as the absence of hot-rolled section steel in the United Kingdom and welded of asymmetric section steel in Finland in the 2000s. It can be increase total floor area about 10%, save the interior and exterior materials, reduce the waste through reduction of the floor height. And it has more excellent fire resistance performance because less exposed than a regular composite steel beam in fire. This study is purpose that, a fire resistance performance of the Asymmetric Slimflor Beam in fire, it compared the temperature range with deflection of structure by fire behavior and load ratio of structure through change the shape of the steel cross-section in standard fire condition.

Evaluation of the performance for the reformed lattice girders (개량형 격자지보재의 성능 평가)

  • Kim, Hak-Joon;Bae, Gyu-Jin;Kim, Dong-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.201-214
    • /
    • 2013
  • Lattice girders are widely used as a substitute for H-steel ribs at domestic tunnels. However, lattice girders have a weak point in terms of the support capacity compare to H-steel ribs because of the lower stiffness and the weakness of the welded parts. To improve the weakness of the lattice girder, reformed lattice girders are developed in Korea by adding one more spider and having flat welded surface. Laboratory tests and field measurements were performed for the original and the reformed lattice girders to evaluate the performance of the reformed lattice girders. According to the laboratory compression test, reformed lattice girders have 16% higher load bearing capacity than that of original lattice girders. Reformed lattice girders are more stable than original lattice girders because reformed lattice girders tend to bend less according to the field measurements.

Minimum Weight Design of Built-up T Based on HCSR (HCSR 기반 T형 조립부재의 최소중량설계)

  • Shin, Sang-Hoon;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.389-394
    • /
    • 2017
  • In a conventional ship structure, stiffeners with an asymmetric section, such as inverted angles, are used widely despite the disadvantage of strength compared to the stiffeners with a symmetric section, such as a built-up T. On the other hand, T-type built-up members are attracting more attention than L-type inverted angles due to the increased size of ships. The purpose of this study was to develop an optimal design program for a built-up T, and apply an evolution strategy as an optimization technique. In the optimization process, the gross thickness concept was adopted for the design variables and objective function, and the constraints are set up based on HCSR (Harmonized Common Structural Rules). Using the developed program in this study, the optimal stiffener design was carried out for 300K VLCC and 158K COT of which the orders were obtained lately. The optimal results revealed the weight reduction effect of 144 tons and 60 tons, respectively.

The Behavior of Anchor Connections of Cold-Formed Steel Roof Truss (경량형강 지붕트러스 앵커부의 거동)

  • Kwon, Young Bong;Kang, Sueng Won;Chung, Hyun Suk;Choi, Young Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.519-529
    • /
    • 2003
  • In recent years, the use of cold-formed steel roof truss has been increased in the steel houses and high-rise apartments. The design of the roof truss anchor connections has been based on the experience and decision of designers. In this paper, the structural behavior of anchor connections based on experimental and decision is described. In the tests, truss members and connection members were jointed directly with self-drilling screw fasteners and the simple shaped connection member with excellent workability and structural capacity was used to connect roof truss and sub-structure. The connecting method was selected according to the construction material of sub-structure: chemical anchor for reinforced concrete structure and welding or DX-Pin for steel structures. The pull-out tests of various type anchor connection were executed to obtain the strength and the stiffness and the result have been compared with AISI(1996) and AlSC(1989) specifications, Simple formulas for the shear strength of screw connections have been propose and compared with tests.

Load Transfer Mechanism of the Hybrid Beam-Column Connection System with Structural Tees (T 형강을 사용한 합성골조 보-기둥 접합부의 하중전달 메카니즘)

  • 김상식;최광호
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.823-829
    • /
    • 2002
  • The composite frame system with reinforced concrete column and steel beam has some advantages in the structural efficiency by complementing the shortcomings between the two systems. The system, however has also a lot of problems in practical design and construction process due to the material dissimilarities. Considering these circumstances, this research is aimed at the development of the composite structural system which enables the steel beams to be connected to the R/C columns with higher structural safety and economy. Basically the proposed connection system is composed of four split tees, structural angles reinforced by stiffener, high strength steel rods, connecting plates and shear plates. The structural tests have been carried out to verify the moment transfer mechanism from beam flange to steel rods or connecting plates through the angle reinforced by siffener. The four prototype specimens have been tested until the flange of beam reached the plastic states. From the tests, no distinct material dissimilarities between concrete and steel have been detected and the stress transfer through wide flange beam - structural angle - high strength steel rod or connecting plate is very favorable.