• 제목/요약/키워드: 용접성 평가

검색결과 496건 처리시간 0.043초

AE방법에 의한 Flash Butt 용접부의 파괴거동 평가 (An Evaluation of the Fracture Behavior for Flash Butt Welding zone by Acoustic Emission Method)

  • 김용수;이하성;강동명
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.9-18
    • /
    • 1994
  • In this study, we conducted experimental tests to evaluate fracture behaviors of fresh-butt welded metal by Acoustic Emission technique. We selected similar welding and dissimilar welding process, the one welded for SM45C, SS41 and SUS304 of each material, the other for SM45C and SS41, SM45C and SUS304 and SS41 and SUS304. The fracturing processes of weld metal were estimatied through the fracture toughness test with compact tension specimens and fractography analysis. In ASTM test method E-399, type I curves for materials of this study were obtained by load-cod diagram of fracture toughness test. and 5% offset load( $P_{5}$) was estimated as the estimated crack initial load( $P_{Q}$), The estimated crack initial load( $P_{Q}$) of similar welding materials generally lower than base matal, and then SM45C appeared greatly in decreasing rate of PB, SS41 and SUS304 appeared in order. $P_{Q}$ of dissimilar welding materials were lower than the similar welding materials. $P_{Q}$ of welding of SM45C and SS41 appeared in small, SUS304 and SS41 appeared greatly in dissimilar welding materials. In fracture toughness test, AE counts increased before the inflection point of the slope, decreased after that. It was found that increasing of AE counts were due to the microcrack formation at the crack tip near the $P_{5}$ point through AE data. For welding materials in this study, both low and high AE amplitude appeared simulataneously. It was confirmed that the low AE amplotude was due to formation of micro void, micro crack or micro dimple, the high AE amplitude was caused by microvoid coalescence and quasi-cleavage fracture through analyses of fractograpy.apy.apy.apy.

  • PDF

직결나사 연결 접합부에 관한 구조성능평가 연구 (A Study of Structural Performance of Self-Drilling Screw Connections)

  • 박기연;전상현;김영호;최성모
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.543-553
    • /
    • 2013
  • 춤이 깊은 골형 데크는 그 단면의 형태가 개방형 단면(개단면(開斷面))으로 단면의 불안정성에 의한 휨비틀림 등의 구조적 문제를 일으킬 수 있다. 박판의 냉간성형강인 데크와 캡플레이트의 접합에 사용되는 연결재(파스너)는 볼트, 리벳, 용접 그리고 나사 접합이 있다. 이 연구는 냉간성형강을 사용한 춤이 깊은 데크와 보강용 캡플레이트간의 직결나사 접합부에 관한 실험적 연구로, 직결나사 접합부의 파괴거동과 최대내력에 영향을 주는 직결나사 배치방법, 직결나사 수, 직결나사 간격 그리고 직결나사 머리밑판의 두께변화를 실험변수로 하여 국외 설계기준식 비교 분석하고자 한다.

단부 철근콘크리트-중앙부 철골로 구성된 복합(複合)보의 거동(擧動)에 관한 실험적 연구 (An Experimental Study on the Behavior of Hybrid Beam Composed of End Reinforced Concrete-Center Steel)

  • 강병수;김성은;최현식
    • 한국강구조학회 논문집
    • /
    • 제14권3호
    • /
    • pp.413-421
    • /
    • 2002
  • 본 연구에서는 반복 재하실험에 의해서 단부 철근콘크리트 중앙부 철골로 이루어진 복합보의 접합부 형상에 따른 역학적 거동을 파악하고자 한다. 실험결과와 종국내력식을 비교 검증하고 합성효과, 내진성능 및 응력전달의 유효성을 검토한다. 각 실험체의 유형은 주근용접형, 정착판 보강형, 시어코넥터 보강형, 시어코넥터형으로 한다. 그 결과 정착판 보강형과 시어코넥터 보강형은 내력 및 내진성능이 우수한 것으로 평가되었으며, 철근콘크리트와 철골 접합부분이 일체성을 확보하여 응력전달에 유리한 것으로 나타났다. 그러나 기존의 종국내력식은 실험결과와 다소 차이가 있는 것으로 나타나 보다 명확한 종국내력식이 요구되고 있다.

조선소 용접작업 중 오존 및 TVOCs의 노출평가와 사용 호흡보호구의 적합성 (Exposure to Ozone and TVOCs during Shipyard Welding and the Adequacy of RPE)

  • 한돈희;김동환
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.200-210
    • /
    • 2018
  • Objectives: The purpose of this study is to assess the exposure to ozone and total volatile organic compounds(TVOCs) generated during welding work at a shipyard and recommend respiratory protective equipment(RPE) adequate against these hazards. Method: Ozone was collected for about 30 minutes at two-minutes intervals using a direct reading instrument, specifically an ozone analyzer(Serinus 10, Ecotech, Australia). TVOCs were collected for about 30 minutes at three-minute intervals using a portable GC (Alpha 115, Synspec BV, the Netherlands), and were determined simultaneously by area sampling at the welding plume closest to the welder's breathing zone. The total measurements were 162 for ozone($CO_2$ welding 47, TIG 60, stick 55), and 136 for TVOCs($CO_2$ 65, TIG 50, stick 21). Based on these measurements, a literature survey was conducted to assess the adequacy of RPE. Results: Relative to Korean OEL, measurements above STEL 0.2 ppm were 23.4% for $CO_2$, 63.3% for TIG and 14.5% for stick welding. There were significant differences(p=<0.0001) among welding types. Compared with ACGIH peak exposure of 0.4 ppm for ozone, which is not applied in Korea, $CO_2$ welding exceeded it by 10.6%, TIG by 40.0% and stick by 7.3%. Although it was not feasible to compare them directly since there are no Korean OEL, TVOCs had very high levels similar to the concentrations before moving into a new apartment and about 10-20 times the indoor air quality recommendations for some individual measurements. Conclusions: As ozone removal RPE has been recommended in welding environments for a long time(Lunau, 1967), this fact was demonstrated based on the results of the on-site work environment measurements(ozone and TVOCs). In conclusion, for all welding at a shipyard, gas/vapor and particulate combination RPE are recommended. If this is not possible, it should at least be present for TIG welding.

타이타늄-구리 폭발압접 이종 클래드 판재의 TIG 용접 건전성 평가 (Evaluation of Welding Soundness of Titanium-Copper Explosive-Bonded Dissimilar Clad Plate by TIG Welding)

  • 조평석;윤창석;황효운;이동근
    • 열처리공학회지
    • /
    • 제34권2호
    • /
    • pp.66-74
    • /
    • 2021
  • Cladding material, which can selectively obtain excellent properties of different metals, is a composite material that combines two or more types of dissimilar metals into one plate. The titanium-copper cladding material between titanium which has excellent corrosion resistance and copper which has high thermal and electrical conductivity, are highly valuable composite materials. It can be used as heat exchangers with high conductivity under severe corrosion conditions. In order to apply the clad plate to the heat exchanger, it must be manufactured in the form of a tube and additional welding is required. It is important to select the cladding material manufacturing process and the welding process. The process of manufacturing the cladding material includes extrusion, rolling, and explosive bonding. Among them, the explosive bonding process is suitable for additional welding because no heat-affected zone is formed. In this study TIG welding of the explosive-bonded dissimilar clad plates was successfully performed by butt welding. The microstructures and bonding interface of the welded part were observed, and the effect of the bonding layer at the welding interface and the intermetallic compounds on the mechanical properties and tensile plastic deformation behaviors were analyzed. And also the integrity of TIG-welded dissimilar part was evaluated.

파형전단연결재의 전단저항 성능 (Shear Capacity of Corrugated rib Shear Connector)

  • 안진희;최규태;김성현;김상효
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.375-381
    • /
    • 2008
  • 본 연구는 기존의 perfobond rib을 절곡시켜 변형시킨 형태인 corrugated rib 전단연결재의 전단강도를 평가하기 위하여 push-out 실험을 통하여 기존의 전단연결재인 stud, perfobond rib 전단연결재와 비교하였다. Corrugated rib 전단연결재의 전단강도에 기여하는 요인인 홀의 유무, 관통철근의 유무, 파형의 파고, rib의 높이 등을 고려하여 총 12본의 push-out 시험체를 제작하였다. 실험결과 corrugated rib 전단연결재 시험체는 콘크리트 슬래브의 지압성 파괴에 의하여 파괴 모드가 결정되었으며, 용접부의 파괴는 발생하지 않았다. 또한 corrugated rib 전단연결재가 perfobond rib 전단연결재보다 최대 96%의 전단저항 성능이 향상됨을 확인하였고, 관통철근의 배근유무에 따라 48%의 전단강도가 증가하는 것으로 나타났다. Corrugated rib 전단연결재의 홀 및 관통철근에 의해 콘크리트 다웰 효과가 증가되었으며, 파형의 파고 및 rib의 높이가 증가할수록 콘크리트 지압저항 영역의 증가로 인하여 전단강도가 증가하는 것을 확인할 수 있었다.

초고성능 콘크리트 바닥판과 역T형 강거더의 합성보를 위한 스터드 및 퍼즐스트립 전단연결재에 관한 연구 (Stud and Puzzle-Strip Shear Connector for Composite Beam of UHPC Deck and Inverted-T Steel Girder)

  • 이경찬;조창빈;최은석;김지상
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.151-157
    • /
    • 2014
  • 초고성능 콘크리트(UHPC)의 높은 강도 및 내구성으로 인하여 교량 바닥판에 UHPC를 적용하는 연구가 활발히 진행되고 있다. UHPC 바닥판은 강도 및 강성이 기존 콘크리트보다 월등히 높아 합성된 강재 거더 상부 플랜지의 구조적 역할을 대신할 수 있을 것이므로, 이 연구에서는 상부 플랜지를 생략한 역T형 거더를 UHPC 바닥판과 합성한 형식을 제안하고자 한다. 역T형 거더를 적용함에 있어 상부플랜지에 전단연결재를 용접하는 방식으로 전단연결재를 설치할 수 없으므로, 새로운 형식의 전단연결재의 개발이 필요하다. 이 연구에서는 3가지 형식의 전단연결재를 제안하고 이들의 정적 극한강도를 실험적으로 평가하였다. 첫 번째 형식은 웨브에 스터드를 횡방향으로 직접 용접한 전단연결재이고, 두 번째는 유럽에서 개발된 퍼즐스트립 형식의 전단연결재이며, 마지막은 횡방향 스터드와 퍼즐스트립을 조합한 전단연결재이다. 실험 결과 횡방향 스터드는 AASHTO LRFD에 제시된 기존 스터드 전단연결재의 강도 설계식 보다 평균 24% 크게 나타났으나, 바닥판에 쪼갬 균열이 현저히 발생하여 이를 방지하기 위한 새로운 대책이 필요한 것으로 나타났다. 퍼즐스트립은 기존 유럽의 연구에서 제안한 극한강도 평가식 보다 40% 큰 강도를 보여, 기존의 평가식이 지나치게 보수적인 것으로 나타났다. 마지막으로 2가지를 조합한 형식의 전단연결재의 극한강도는 각각의 전단연결재의 극한강도를 산술적으로 합한 것보다 작은 극한 강도를 보였고 바닥판에 균열 또한 현저하였으므로, 조합에 따른 상승효과를 기대할 수 없었다.

파형웨브 프리스트레스트 합성보의 휨거동 평가 (Evaluation of Flexural Behavior of Prestressed Composite Beams with Corrugated Webs)

  • 오재열;이득행;김강수;강현;이정연;방용식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.39-40
    • /
    • 2010
  • 건물이 대형화 고층화되어 감에 따라서 층고를 절감시킴과 동시에 장스팬을 구현할 수 있는 부재에 대한 요구가 늘어가고 있다. 비록 많은 연구자에 의해서 층고절감과 장스팬에 대한 요구를 만족시키기 위한 연구가 진행되고 있지만, 여전히 두 가지 요구사항을 동시에 만족시키는 효율적인 시스템이 부족한 실정이다. 본 연구에서 제안하는 파형웨브를 가진 프리스트레스 합성보는 시공성과 구조적인 성능을 동시에 향상시킬 수 있다. 시공과정에서 발생할 수 있는 비대칭 하중에 상대적으로 작은 부재를 가지고 강한 저항성을 발휘하여 시공성을 높일 수 있으며, 또한 동바리와 서포트 등의 가설부재를 줄임으로써 경제성도 확보할 수 있다. 파형웨브는 아코디언효과를 만들기 때문에 프리스트레스의 도입효율이 좋아져 더 큰 상향치올림를 유발시켜 부재의 처짐을 줄일 수 있다. 5개의 실험체를 제작하여 제안한 합성보의 효율성을 검토하였는데 그 주요한 변수로는 웨브와 플렌지에 용접된 형태와 drape point의 개수이다. 실험을 통하여 제안한 프리스트레스 합성보가 기존에 프리스트레스를 도입하지 않은 합성보 보다 큰 휨강성과 휨강도를 발휘한다는 것을 증명하였다.

  • PDF

CANDU 사용후핵연료 저장바스켓 설계 개선안 도출 (Design Enhancement of CANDU S/F Storage Basket)

  • 최우석;서기석;박완규
    • 방사성폐기물학회지
    • /
    • 제10권2호
    • /
    • pp.105-115
    • /
    • 2012
  • 월성원자력본부의 조밀건식저장시설인 MACSTOR/KN-400의 인허가 과정에서 사고조건에 대한 바스켓의 안전성 평가를 위한 실증시험의 필요성이 제기되었다. 실증시험을 위한 낙하시험시설을 한국원자력연구원에 설치하고 바스켓 낙하 실증시험을 수행하였다. 실증시험 결과 실린더 내 적재 바스켓의 상부 용접부가 낙하 바스켓과 충돌하여 파손되고 누설이 발생하였다. 기존 바스켓이 실증시험에서 누설율 성능요건을 만족하지 못함에 따라 바스켓의 설계 개선안 도출이 필요하게 되었다. 설계 개선을 위한 방향을 선정하고 이에 기초하여 6 종류의 설계 개선안을 도출하였다. 개별 설계 개선안에 대하여 구조해석 및 시편시험을 수행하였다. 구조해석 및 시편시험의 결과를 바탕으로 최종설계안을 확정하였다. 최종설계안은 바스켓의 중앙 포스트의 높이를 감소하여 낙하 바스켓과의 충돌속도를 감소시키는 설계안이었다. 최종설계안에 대한 시험모델을 제작하여 낙하실증시험을 재수행한 결과 모든 성능요건을 만족하였다.

PHC파일간 연결 시공성 개선 이음판형 기계적 연결부의 연결저항 (Connection Resistance of Mechanical Joint using Connection plate for Improvement of Connectivity between PHC piles)

  • 안진희;문홍득;하민균;조광일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.25-32
    • /
    • 2019
  • PHC 파일의 파일간 연결공법으로 용접이음과 볼트이음을 이용한 기계적 이음들이 적용되고 있으나 시공과정 등에서 품질 및 성능 확보에 어려움이 발생할 수 있다. 본 연구는 기존 PHC파일 연결부가 가지는 단점을 개선하고 PHC 파일 연결부 성능을 확보할 수 있는 무용접 이음판형 기계적 PHC파일 연결부를 제안하고 비선형 구조해석과 실제 PHC파일 연결부 실험을 통하여 제안된 PHC 파일 연결부의 연결성능을 평가하였다. 제안된 PHC파일 연결부의 비선형 구조해석 결과 연결부는 휨, 압축, 인장, 전단, 편심압축 하중 상태에서 충분한 연결성능을 확보하는 것으로 평가되었으며, 실제 휨하중 재하실험에서 PHC파일의 균열 및 휨 모멘트 수준 이상에서도 안정적인 선형거동을 가지고 있는 것으로 나타났다. 따라서 제안한 무용접 이음판형 기계적 PHC파일 연결부는 충분한 연결성능을 확보할 수 있는 것으로 판단된다.