• Title/Summary/Keyword: 용상

Search Result 309, Processing Time 0.032 seconds

CCD Non-uniformity Correction Method based on Pixel Non-Linearity Model (픽셀 비선형성 모델을 기반으로 한 영상센서 불균일 특성 보정)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • All pixels of image sensor do not react uniformly when the light of same radiance enters into the camera. This non-uniformity has a direct influence on the image quality. However we can overcome it by calibration process under the special test-setup. Usually it is used the algorithm to get the correction coefficients under the specific illumination condition. But, this method has drawback in the very low or very high illumination due to pixel non-linearity. This paper describes the robust algorithm, which calculates the correction coefficients based on the pixel non-linearity model, against thew hole radiance. The paper shows the non-uniformity test results with the own camera and the specified test equipments as well. The results shows the best performance over the entire radiance when this method is applied.

Detection of plcR-papR Genes by PCR in Identifying Enterotoxin Genes-Harboring Bacillus cereus Strains (장독소 유전자 함유 Bacillus cereus 확인을 위한 독소 전사 조절 유전자 plcR-papR의 PCR 검출법)

  • Yun, Suk-Hyun;Kim, Yong-Sang;So, Soon-Ku;Jeong, Do-Yeon;Hahn, Kum-Su;Uhm, Tai-Boong
    • Korean Journal of Microbiology
    • /
    • v.45 no.4
    • /
    • pp.425-429
    • /
    • 2009
  • Identification of virulent Bacillus cereus strains was examined by PCR using primers specific for the detection of plcR-papR, which encode regulatory proteins controlling the transcription of virulence factors in B. cereus. Total 96 strains of B. cereus that carried at least one of diarrheal toxin genes including hblACD, nheABC, and cytK showed all positive PCR products, while other 48 Bacillus strains that lacked the toxin genes were plcRpapR-negative. This PCR method targeting the plcR-papR genes appears to be simple and effective in identifying the enterotoxin genes-harboring B. cereus strains.

A Study on the Optimal Method for Malfunction of Protection Devices in Distribution Systems Interconnected with Photovoltaic Systems (태양광발전이 연계된 배전계통에서 보호협조기기의 오동작에 대한 최적 방안에 관한 연구)

  • Rho, Dae-Seok;Kim, Chan-Hyeok;Shin, Chang-Hoon;Jeong, Won-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1599-1606
    • /
    • 2008
  • Recently, new dispersed generation systems such as photovoltaic, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy with the provision against oil crisis. The technical guidelines on the interconnection of dispersed generation systems have been established and conducted positively. However, protection devices (Re-closer) in primary feeder of distribution system interconnected with photovoltaic generation may cause problems with mis-operation, and then many customers could have problems like an interruption. So, this paper presents the optimal method to minimize the impact of interruption, using both the symmetric method and MATLAB/SIMULINK. And, also this paper shows the effectiveness of proposed method by simulating at the real distribution systems.

Characterization of Microfluidic system integrated with micropump and microvalve (초미세 유체 제어 시스템 구현을 위한 마이크로 펌프와 밸브의 집적)

  • Yoo, Jong-Chul;Her, Hyun-Jung;Choi, Y.J.;Kang, C.J.;Kim, Han-Soo;Lee, Kyoung-Il;Shin, Jin-Koog;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1645-1646
    • /
    • 2006
  • Micro ElectroMechanical Systems (MEMS) 기술을 이용한 초미세 유체 제어 시스템 (마이크로 펌프, 마이크로 밸브, 마이크로 채널, 마이크로 믹서 등)은 화학, 생명분야의 DNA 분석, 항원-항체 분석, 질병의 진단 등에 사용되는 lab-on-a-chip, micro total analysis system ($\mu$-TAS) 등에서 화학 및 바이오 유체를 제어하는 분석 시스템의 일부분으로서 사용되며 필수적으로 요구된다. 본 논문에서는 이러한 microchip을 구현하기 위해 초미세 유체 제어 소자인 마이크로 펌프와 밸브를 같은 기관 위에 polydimethylsiloxane (PDMS)와 indium tin oxide (ITO)-Glass를 사용하여 동일한 구조로 집적 하였다. 마이크로 펌프의 pumping rate은 인가 직류 펄스 전력의 주파수와 duty 비를 변화시켜 최적화하였다. 직류 펄스 전력 500 mW를 인가하였을 때 주파수 2 Hz, duty 비 7 %에서 약 $1.05{\mu}l/min$의 최대 유량이 측정되었다. 마이크로 밸브는 ITO 히터에 전력을 인가함으로서 유량의 on/off 제어가 잘 됨을 확인할 수 있었고 유체를 closing하기 위해 필요한 전력은 약 300 mW이다.

  • PDF

Fabrication of Nano Probe for Atomic Force Microscopy Using Electron Beam Direct Deposition Method (전자빔 직접 조사법을 이용한 AFM용 나노 프로브의 제작)

  • Park, Sung-Hwak;Yi, In-Je;Kim, Yong-Sang;Sung, Seung-Yeon;Kim, Jae-Wan;Choi, Y.J.;Kang, C.J.;Kim, Sung-Hyun;Shin, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1649-1650
    • /
    • 2006
  • 반도체 소자의 선폭이 나노미터 스케일로 진입함에 따라 소자의 물리적 특성을 나노미터 스케일에서 정밀하게 측정하고자 하는 요구가 증대되고 있다. Atomic Force Microscopy (AFM)은 나노미터 이하의 해상도를 가지고 물질 표면의 기하하적, 전기적 특성 등을 측정할 수 있으므로 나노소자 연구에 필수적인 도구가 되었다. 그러나 AFM은 낮은 측정속도와 탐침의 기하학적 형상에 의한 AFM 영상의 왜곡 등과 같은 치명적인 단점도 가지고 있다. AFM의 낮은 측정 속도를 개선하기 위해서 진보된 마이크로머시닝기술을 이용하여 캔틸레버의 크기를 줄이거나 캔틸레버 위에 박막 구동기를 집적시키는 등의 노력이 진행되고 있으나, 이 경우 전통적인 식각 공정을 이용하여 캔틸레버 위에 tip을 형성하는 것이 매우 어렵다. 본 연구에서는 이미 제작된 캔틸레버 위에 전자빔 조사법을 이용하여 탄소상 tip을 직접 성장시킴으로써 전통적인 식각 공정에 비해 매우 간단하고 값싸며, 활용도가 높은 공정을 개발하였다. 탄소상 tip 성장에 필요한 탄소 소스는 dipping 방법을 이용하여 공급하였고, 시분할법을 사용하여 캔틸레버의 원하는 위치에 tip을 성장시킬 수 있었다. 이렇게 제작된 tip은 최대 $5{\mu}m$ 높이까지 가능했으며, 종횡비는 10:1 이상이어서 tip의 형상에 의한 AFM 영상 왜곡 현상을 최소화할 수 있을 것으로 기대된다.

  • PDF

The Growth Characteristics of Spirulina platensis in Cylindrical Photobioreactor (관형 광생물 반응기에서의 Spirulina platensis 성장 특성 연구)

  • 김용상;박호일;김동건;박대원
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.277-281
    • /
    • 2003
  • The study of growth characteristics for Spirulina platensis were carried out in 400 mL cylindrical photobioreactor and the effects of carbon dioxide concentration and flow rate during the growth of Spirulina platensis were investigated. The results showed that relatively low carbon dioxide concentration and high flow rate forced the growth of Spirulina platensis in experiment conditions. The pH analysis showed that different carbon dioxide concentration might form particular aqueous carbonate system in culture medium and affect the growth of Spirulina platensis. In addition, the possibility of limiting light radiation by cell density was investigated by the analysis of specific growth rate. The result intimated that the cause of decrease of specific growth rate at exponential phase was due to the limitation of light radiation by Spirulina platensis cell density in cylindrical photobioreactor.

The Relationships among Stress Perception, Locus of Control and Depressive Symptom of The Patients with Psychological Pruritis and Chronic Urticaria (심인성 소양증환자와 만성 담마진환자의 스트레스지각과 통제소재 및 우울증상과의 관계)

  • Lee, Young-Ho;Ko, Dae-Kwan;Han, Ki-Seok;Chung, Young-Cho;Kim, Yong-Sang;Lim, Sung-Chun;Nam, Ki-Heum;Kim, Chung-Ho
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.3 no.2
    • /
    • pp.126-138
    • /
    • 1995
  • For investigating a disease specific psychological mechanism in various dermatological disorders, we tried to explore the difference in correlation among stress perception, locus of control as a coping strategy, depressive symptoms and pruritic symptoms in the patients with psychological pruritis and chronic urticaria. The subjects were composed of 32 patients with psychol-ogical pruritis and 67 patients with chronic urticaria(subject group), and 25 patients with organic pruritis and 59 patient with major depression(control group). Global assesment of recent stress scale(GARS), I-E locus of control scale, Beck Depression Inventory(BDI) and medical college of wisconsin center pain follow up questionnaire were used for assesement. The results were as follows: 1) There were a significant positive correlation between stress perception and depressive symptom in patients with psychological pruritis, chronic urticaria, and major depression but not hi organic pruritis. 2) In relationship between locus of control and depressive symptom, patients with psychological pruritis, organic pruritis, and major depression except chronic ruticaria showed a significant negative correlation. 3) For intensity and pattern of pruritis, there were positive relations with depressive symptom and stress perception only in patients with chronic urticaria. Above results indicate that stress perception and locus of contorl may play a significant role in the formation of psychological and dermatological symptoms in psychological pruitis and chronic urticaria. But the mechanisms of these processes are different in either disorder.

  • PDF

Analysis of the Output Characteristics of IGZO TFT with Double Gate Structure (더블 게이트 구조 적용에 따른 IGZO TFT 특성 분석)

  • Kim, Ji Won;Park, Kee Chan;Kim, Yong Sang;Jeon, Jae Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.281-285
    • /
    • 2020
  • Oxide semiconductor devices have become increasingly important because of their high mobility and good uniformity. The channel length of oxide semiconductor thin film transistors (TFTs) also shrinks as the display resolution increases. It is well known that reducing the channel length of a TFT is detrimental to the current saturation because of drain-induced barrier lowering, as well as the movement of the pinch-off point. In an organic light-emitting diode (OLED), the lack of current saturation in the driving TFT creates a major problem in the control of OLED current. To obtain improved current saturation in short channels, we fabricated indium gallium zinc oxide (IGZO) TFTs with single gate and double gate structures, and evaluated the electrical characteristics of both devices. For the double gate structure, we connected the bottom gate electrode to the source electrode, so that the electric potential of the bottom gate was fixed to that of the source. We denote the double gate structure with the bottom gate fixed at the source potential as the BGFP (bottom gate with fixed potential) structure. For the BGFP TFT, the current saturation, as determined by the output characteristics, is better than that of the conventional single gate TFT. This is because the change in the source side potential barrier by the drain field has been suppressed.

Pentacene Thin-Film Transistor with Different Polymer Gate Insulators (게이트 절연막에 따른 펜타신 박막 트랜지스터의 전기적 특성 분석)

  • Kim, Jae-Kyoung;Her, Hyun-Jung;Kim, Jae-Wan;Choi, Y.J.;Kang, C.J.;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1345-1346
    • /
    • 2007
  • 다양한 게이트 절연막의 펜타신 박막 트랜지스터의 전기적 특성을 atomic force microscope (AFM), X-선 회절을 사용하여 분석하였다. 펜타신 박막 트랜지스터는 thermal evaporator 방법을 사용하여 여러 폴리며 기판위에 제작하였다. Hexamethylsilasane (HMDS), polyvinyl acetate (PVA), polymethyl methacrylate (PMMA)등의 폴리머 기판을 사용하여 다양한 온도에서 증착시켰다. 이 때 PMMA위에 증착시킨 펜타신의 경우가 가장 큰 그레인 크기를 보였고, 가장 적은 트랩 농도를 보였다. 그리고 상부 전극 구조를 가진 박막 트랜지스터를 HMDS 처리를 한 $SiO_2$와 PMMA 절연막을 사용하여 제작하고 비교하였다. 이때 PMMA기판 위에 제작한 트랜지스터는 전계효과 이동도가 ${\mu}_{FET}=0.03cm^{2}/Vs$ 이고, 문턱이전 기울기 0.55V/dec, 문턱전압 $V_{th}=-6V$, on/off 전류비 $>10^5$의 전기적 특성을 보였고, $SiO_2$ 기판위에 제작한 트랜지스터는 전계효과 이동도 ${\mu}_{FET}=0.004cm^{2}/Vs$, 문턱이전 기울기 0.518 V/dec, 문턱전압 $V_{th}=5V$, on/off 전류비 $>10^4$의 전기적 특성을 보였다.

  • PDF

Tropical Cyclone Center and Intensity Analysis from GMS-4 TBB data (GMS-4 $T_{BB}$ 자료를 이용한 태풍의 중심 및 강도 분석)

  • 김용상;서애숙;신도식;김동호
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.2
    • /
    • pp.111-125
    • /
    • 1996
  • A forecast technique using GMS-4(Geostationary Meteorological Satellite) infrared images and its $T_{BB}$ (Brightness Temperature) data to determine the tropical cyclone center and to analyze the tropical cyclone intensity has been developed. First, the determination of typhoon center using $T_{BB}$ distribution pattern is practiced by understanding a special feature of central cloud pattern and cloud band which is analyzed with the method of pseudo coloring. Then, to forecast the intensity of tropical cyclone, a relationship between the central pressure (or maximum wind speed) of tropical cyclone and $T_{BB}$ measured by GMS near the tropical cyclone center was investigated. The results showed a correlation with a high lag relationship between central pressures and $T_{BB}$. The mean Tee in the ring of 200~300km apart from the tropical cyclone center showed the best correlation to central pressure of the tropical cyclone after 24hour. From this relationship, a regression equation to forecast the central pressure (or maximum wind speed) was derived.