• Title/Summary/Keyword: 외측다이아프램

Search Result 7, Processing Time 0.023 seconds

Structural Characteristic of Beam-to-Column Connections in Rectangular CFT Structures Considering Concrete Filling (충전성을 개선한 각형CFT 기둥-보 접합부의 구조 특성)

  • Park, Je Young;Lee, Myung Jea
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • CFT structures require a diaphragm to prevent buckling of steel at connections. An outer diaphragm has better concrete filling than a through diaphragm due to a large bore, but due to the larger size than the through diaphragm, it has poorer constructability and cooperation with building equipment. The building structure has a floor slab that was unified with the upper diaphragm, so the outer diaphragm was placed at the upper bound. Moreover, the through diaphragmwas placed at the lower connection to avoid obstruction of the building equipment. The CFT structure with the improved concrete filling showed the same structural behavior as the CFT structure with the use of the same type of diaphragms at the upper and lower connections.

Structural Behavior of Beam-to-Column Connections of Circular CFT Structures Improving Concrete Filling (충전성을 개선한 원형 CFT구조의 기둥-보 접합부 구조적 거동)

  • Park, Min-Soo;Kim, Hee-Dong;Lee, Myung-Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.737-745
    • /
    • 2011
  • A concrete-filled tube is a concrete-filled steel tube structure. The steel tube confines the concrete to increase the compressive strength, and the concrete contains the buckling of the tube. CFT structures require a diaphragm to prevent buckling of steel at connections. An outer diaphragm has better concrete filling than a through diaphragm due to a large bore, but being larger than the through diagram, it has poorer constructability and cooperation with building equipment. In this study, a CFT structure that uses different types of diaphragms in its upper and lower connections to improve the concrete filling was tested and analyzed via the FEM program. The building structure had a floor slab that was unified with the upper diaphragm, so the outer diaphragm was placed at the upper bound. Moreover, the through diaphragm was placed at the lower connection to avoid obstruction from building equipment. The CFT structure with the improved concrete filling showed the same structural behavior as the CFT structure with the use of the same type of diaphragms at the upper and lower connections.

Structural Characteristics of Beam-to-Column Connection of Circular CFT Columns by Using Mixed Diaphragms (혼합다이아프램 형식을 적용한 콘크리트충전 원형강관 기둥-보 접합부의 구조적 특성)

  • Wang, Ning;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.299-310
    • /
    • 2015
  • CFT(Concrete-Filled Tube) structures have problems at processing cause closed section and concrete filling problems. In this study, a CFT structure that uses different types of diaphragms in its upper and lower connections to improve the concrete filling was tested and analyzed via the FEM program. Implementation of variable analysis of EP-T type to find out the reason that effect on the resistance force of the connection. As a result, through experiments and analysis investigated the structural characteristics of circular CFT beam-to-column connection.

Seismic Behavior of H shaped Beam to Square Column Connection with Outer Diaphragm Using Field Welding (외측 다이아프램을 사용한 현장 용접형 각형강관기둥-H형강보 접합부의 이력거동)

  • Seo, Seong Yeon;Jung, Jin Ahn;Choi, Sung Mo;Kim, Sung Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.459-467
    • /
    • 2005
  • This study focuses on the development of a new method of H-shaped beam-to-square column connection with an outer diaphragm and a field welding. The specific type of beam-to-column connection with an external stiffener, using field welding, is proposed. The structural behavior of this connection was examined experimentally. Two loading type tests were conducted under the experimental parameters given as details. First described was the symmetrical loading test, which supported both ends or a beam simply and applied a load from the column to the pend (What does this mean?) to investigate a fundamental characteristic of this connection. Further described was the anti-symmetrical loading test, which carried out simple support of the column'stop end and the column base, and applied a load from both ends of a beam to investigate the structural performance of this connection. From the results, it is clear that the external- stiffener-type connection proposed in this paper is the reliable connection method.

The Strength of Square Steel Tubular Column to H-beam Connections - Focused on the connections with outside-type diaphragm - (각형강관 기둥 - H형강 보의 접합부 내력 평가 - 외측형 다이아프램 접합부를 중심으로 -)

  • Lee, Seong Do;Kim, Pil Jung;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.11-20
    • /
    • 2004
  • This paper focused on square steel tubular column to H-beam connections (concrete filled tubular) with an outside-type diaphragm. Based on the yield line theory and the nonlinear static FEM analysis the specification equations were evaluated by comparing them with previous result of the simplified tensile experiment[please check. The yield line theory applied to the mechanical model theory revised by K. Morita, the nonlinear static FEM analysis using abaqus/standard, the ultimate strength equation in the specification equation using the factor for long-time loading, and the yield ratio according to material. The allowable strength in the specification equations applied the safety factors of 2.2 and 2.6 in the cases with and without filled concrete, respectively. Therefore, the evaluation of strength(for the previous result of the simplified tensile experiment in this study) was considered possible through the yield line theory, the nonlinear static FEM analysis, and the specification equations. Likewise, the specification equations were seen to be an underestimate of the previous result of the simplified tensile experiment. The strength and displaced mesh in the FEM analysis approximated the previous result of the simplified tensile experiment.

An Experimental Study on the Strength of the Frame consisting of Concrete Filled Steel Tubular Column-H Beam under Alternately Repeated Horizontal Loading (반복하중을 받는 콘크리트충전 강관기둥-H형강보 골조의 강도에 관한 실험적 연구 -접합부 보강형식과 콘크리트충전에 따른 효과-)

  • Lee, Seong Do;Kim, Pil Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.641-655
    • /
    • 1998
  • It researched several jointing-methods of frame consisting of a concrete-filled steel tubular column and H-shaped beam. These beam-to-column connections is parameters to following: columns of square shape pipe infilled with or without concrete, joints assembled two types of diaphragm, outside-type and through-type. And it is testing that cyclically lateral loadings used hydraulic ram. In testing. we'll be on purposed to estimate the hysteretic behavior, strength and stiffness, energy absorption capacity, deformation capacity and failure configuration of each specimen. It is concluded that the frame specimens with outside-type are more stable and exhibit more energy absorption capacity compared with the through-type, in column of filled with concrete.

  • PDF

Performance Evaluation of Connection of Seismic Rectangular Steel Tube Column-H Beam Using One-side Bolts (원사이드 볼트를 이용한 내진 각형강관 기둥-H형강 보 접합부의 구조성능평가)

  • Shim, Hyun-Ju;Jang, Bo-Ra;Chung, Jin-An;Lee, Eun-Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.355-363
    • /
    • 2010
  • The objective of this study is to examine the structural performance on the Rectangular Steel Tube Column-to-H Beam connections using one-side bolts and T-stub. Although a rectangular steel tube comparing with a H-shaped steel has many advantages and is more efficient, its application is limited due to the lack of experiences and connection details. Existing steel moment connections using the rectangular steel tube are mainly using through plate diaphragms. Its processing of construction is so complicated that it is hard to apply in the field. In this study, the structural performance and the earthquake capacity for T-stub connection with one-side bolts were investigated. And it is performed a comparative analysis of strength, rigidity, total rotation and energy absorption capacity for the various connection details.