• Title/Summary/Keyword: 외부

Search Result 14,570, Processing Time 0.038 seconds

Analysis of Teachers' Perceptions to Establish the Management Direction of Outdoor Space in an Elementary School (초등학교 외부공간 관리방향 설정을 위한 교사의 인식 분석)

  • Jeong, Na-Ra;Jeong, Hyun-Jeong
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.3
    • /
    • pp.38-47
    • /
    • 2020
  • This study analyzed the perceptions of teachers to establish the direction for managing the space outside an elementary school. Satisfaction with outdoor school spaces is influenced by the satisfaction with tree and flower plantation and outdoor rest spaces. This study found that the longer the working years of a teacher, the higher their awareness of the importance and necessity of outdoor spaces in the school. Respondents emphasized the lack of manpower and budget, as well as the indifference of the administration as hindrances to the management of outdoor spaces in the school. The outdoor space in the school should include a secure play area, plant education space, class practice spaces, and a rest area. Furthermore, the space outside the elementary school should support learning, playing, and resting. To this end, facilities such as benches, pergolas, outdoor classrooms, ecological ponds, farms, and flower beds should be provided. In an outdoor space, plants featured in textbooks, seasonal plants, and those that provide shade can be planted along with labels to provide information and thereby promote learning. The teachers expected that the management of the external space will have an educational and emotional effect on students. In response to the innovation of the school spaces, it is necessary to continuously manage the external spaces to achieve educational and emotional effects by organically connecting the outdoor spaces with the indoor space. For this purpose, it is required to provide support for securing budgets and manpower, and to introduce relevant policies.

Water wave reflection over shear currents and dredged multi-arrayed trenches (외부 흐름과 준설된 다열 함몰지형에 의한 파랑의 반사)

  • Cho, Yong-Sik;Lee, Kwang-Jun;Lee, Jun-Whan
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.871-876
    • /
    • 2020
  • Understanding the wave characteristics near the outlet of coastal power plants for cooling water in the vicinity of the dredged areas is critically important for the construction and operation of the plants. By Employing the eigenfunction expansion method, in this study, we analyzed the reflection of monochromatic water waves over (1) shear currents near the outlet and (2) multi-arrayed trenches representing dredged areas. We firstly optimized the number of grids expressing shear currents and the number of evanescent modes based on a convergence test. We then analyzed the sensitivity of the reflection coefficients depending on (1) magnitude of shear currents, (2) width of shear currents, (3) a distance between adjacent trenches, and (4) a number of trenches. The results showed that the reflection coefficient was more sensitive to the number of trenches and the distance between trenches than the velocity of shear currents and the width of shear currents. We also found that even the effect of shear currents is relatively small, the effect is not negligible in a relative water depth from shallow to near shallow water waves (0.01 < kh ≦ 0.70).

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

Experiment on Camera Platform Calibration of a Multi-Looking Camera System using single Non-Metric Camera (비측정용 카메라를 이용한 Multi-Looking 카메라의 플랫폼 캘리브레이션 실험 연구)

  • Lee, Chang-No;Lee, Byoung-Kil;Eo, Yang-Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.4
    • /
    • pp.351-357
    • /
    • 2008
  • An aerial multi-looking camera system equips itself with five separate cameras which enables acquiring one vertical image and four oblique images at the same time. This provides diverse information about the site compared to aerial photographs vertically. The geometric relationship of oblique cameras and a vertical camera can be modelled by 6 exterior orientation parameters. Once the relationship between the vertical camera and each oblique camera is determined, the exterior orientation parameters of the oblique images can be calculated by the exterior orientation parameters of the vertical image. In order to examine the exterior orientation of both a vertical camera and each oblique cameras in the multi-looking camera relatively, calibration targets were installed in a lab and 14 images were taken from three image stations by tilting and rotating a non-metric digital camera. The interior orientation parameters of the camera and the exterior orientation parameters of the images were estimated. The exterior orientation parameters of the oblique image with respect to the vertical image were calculated relatively by the exterior orientation parameters of the images and error propagation of the orientation angles and the position of the projection center was examined.

Effect on the Externally Stained IPS e.max Press Porcelain Due to Tooth Brushing (칫솔질이 IPS e.max Press 도재의 외부 stain에 미치는 영향)

  • Park, Chan;Lee, Gyeong-Je;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.213-221
    • /
    • 2012
  • The purpose of this study was to evaluate the stability of external stain that long term attrition caused by tooth brushing affected the color variation of external stain of IPS e.max Press Porcelain. The specimen was made by IPS e.max Press LT ingots, and treated the shade of external staning as Orange, A, B, C, D After conducting horizontal toothbrush strokes about 11,000 / 22,000 / 44,000 / 66,000 / 88,000, Color changers of the external stained layer was measured with SpectroShade$^{tm}$ MICRO(MHT, Italy). The result of this study was obtained as follows: 1. After 11,000 strokes, the color changes of shade were greater in Orange shade than the other 4 shade groups. And even though toothbrush strokes were increased until 88,000, there were no statistical significant color changes about the external stain shade variation. 2. The amount of color variation about increasing of toothbrushing strokes was irregular(no consistent increasing, or decreasing), and it was no statistical significant changes According to these results, the long term tooth-brushing doesn't affect the changes of external stain about IPS e.max press porcelain. And it doesn't reduce the stability of external stain clinically. Later, it will be needed to study other factors affecting the external stain.

Evaluation on the External Restraint Stress in Mass Concrete (매스콘크리트의 외부구속응력에 관한 검토)

  • 강석화;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.111-122
    • /
    • 1996
  • The effects of external restraint on the thermal stresses i n mass concrete are investigated through a series of parametric study. Two major factors affecting the degree of external restraint such as the ratio of length to height of the placed structure (L/H) and the elastic modulus of base structure ($E_r$) are employed as the parameters in a condition which a placing height H is 1.0m. Various conditions of I,/H and E, are analysed by a FEM program and the relationship between these two parameters is examined. The shape of stress distribution due to the external restraint is shown as linearity on the height direction of the section, and is influenced by L/H, $E_r$, and strength development of placed concrete. The external restraint can be devided by two part. One is an axial restraint and the other is a flexural restraint. When the level of external restraint is low, the structure behavior is mainly governed by flexural restraint, otherwise it is dependent on axial restraint. Comparing the calculated stress by the method of the ACI 207 committee with a finite element analysis, the fbrmer overestimates the external restraint stress when the degree of external restraint is weak, and underestimates when it is strong.

Estimation of Appropriate Reinforcement Length of Casing for the Pile of Pile Bent System through Numerical Analysis (수치해석을 통한 단일형 현장타설말뚝 외부강관의 적정 보강길이 산정)

  • Yang, Wooyeol;Kim, Wanho;Lee, Kangil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.6
    • /
    • pp.5-15
    • /
    • 2021
  • One of the construction methods applied as a pier foundation type is a single type cast-in-place pile. In applying a pile bent system as a foundation type, the main concern in designing can be said to secure the lateral bearing capacity of pile structure in system. In addition, to increase the rigidity of the pile structure, a method of increasing the lateral bearing capacity by reinforcing the pile structure with a casing has been used. However, although the reinforcing effect and appropriate reinforcing length of casing may vary depending on the soil conditions, there is insufficient studies on this, and for this reason, the entire pile structure in a pile bent system is reinforced with a casing, in the field. In addition, if the length of the entire pile is reinforced with a casing, it may lead to delays in construction and increase in construction costs. That is, in order to more effectively reinforce the pile structure with a casing, it is necessary to study the lateral bearing characteristics of the reinforced pile structure in system. And it should be determined the appropriate reinforcing length of the casing from the evaluated bearing characteristics. Therefore, in this study, the lateral bearing characteristics of piles applied with the reinforcing length of casing for each condition were evaluated through a numerical analysis. And, based on the analysis results, the appropriate reinforcing length of casing was proposed. As a result of the study, it was found that in order to effectively increase the lateral bearing capacity of pile structure, the reinforcing length of casing should be applied twice the influence range of the bending behavior of the pile, 1/β.

Characteristics of an External-Cavity Semiconductor Laser with a Fabry-Perrot Etalon inside the External reflector (외부공진기 내에 훼브리 페롯 에탈론이 삽입된 반도체 레이저의 특성)

  • 이명우;서동선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.6
    • /
    • pp.793-801
    • /
    • 1993
  • We show theoretically that the performance characteristics of an external cavity semiconductor laser, such as frequency locking and frequency noise reduction, can be greatly improved by just inserting a high finesse Fabry-Perrot(F-P) etalon inside the external reflector. For example, when the F-P etalon of finesse 30 and optical thickness 1.5cm is inserted inside the external cavity of length 3.0cm, the frequency locking accuracy and the linewidth reduction ration are increased up to 7.6 times and 86 times respectively compared with the conventional external-cavity laser under the same operation condition.

  • PDF

Experimental Study on the Composite Beam Strengthened by External Post Tensioning (외부 후긴장으로 보강한 합성보에 대한 실험적 연구)

  • Kim, Gi Bong;Chung, Young Soo;Choi, Hyok Chu;Kang, Bo Soon
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.701-708
    • /
    • 1998
  • The application of additional post-tensioning tendons has recently been widely considered and requires very little interference with the existing structure. Several bridges on the national roadway designed as the second class were strengthened by external post-tensioning for the capacity enhancement purpose, but much of that strengthening work was not verified analytically as well as experimentally. This paper examines experimentally the behavior of simple composite steel-concrete beams designed as the second class(DB-18) When they are strengthened with external post-tensioning tendon. Test results show that external post-tensioning increases the ultimate load and the magnitude of tendon force increases the yield load but not the ultimate load.

  • PDF

Breakdown Voltage Characteristics of LDMOST with External Field Ring (외부 전계 링을 갖는 LDMOST의 항복전압 특성)

  • Oh Dong-joo;Yeom Kee-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.8
    • /
    • pp.1719-1724
    • /
    • 2004
  • In this paper, we have proposed a new structure of LDMOST, which has been expected as a next generation RF power device, to improve the BV(Breakdown Voltage) characteristics. The proposed structure, named external field ring, is formed around a drift region by the three dimensional structure. The external field ring relieves the electric field in the drift region and improves the BV characteristics. By the three dimensional TCAD simulations, it was found that the BV of LDMOST was increased by the increase of the junction depth and doping concentration of the external field ring. Therefore, the BV characteristics of the LDMOST can be remarkably improved by addition of external field ring using an existing p+ sinker process.