Analysis of Relations between Ice Accretion Shapes and Ambient Conditions by Employing Self-Organization Maps and Analysis of Variance (자가조직도와 분산분석을 활용한 결빙 형상과 외기 조건의 관계 분석)

  • Son, Chan-Kyu;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.8
    • /
    • pp.689-701
    • /
    • 2011
  • The relations between ambient conditions and ice accretion shapes are quantitatively analyzed by employing self-organization maps and analysis of variance. Liquid water contents(LWC), mean volumetric droplet diameter(MVD), ambient temperature and free-stream velocity are chosen as ambient conditions which change ice accretion shapes. The parameters of ice accretion shape are selected as maximum thickness, icing limits, ice heading, and ice accretion area. Qualitative analysis was conducted by employing self-organization maps which show the qualitative relations between ice shapes and ambient conditions. The quantitative results of analysis of variance yield intensity of ambient conditions to the parameters of ice accretion shapes.

Characteristics of the 80MPa High Strength Concrete according to the Hot Weather Outside Temperature conditions (서중 외기온도 조건에 따른 80 MPa 고강도콘크리트의 특성)

  • Jung, Yong-Wook;Lee, Seung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.688-696
    • /
    • 2016
  • This paper evaluates the effect of hot weather conditions on the fresh concrete characteristics of 80-MPa high-strength concrete. The slump flow, packing ability, setting time, hydration heat, and compressive strength were evaluated under exterior temperatures of $20^{\circ}C$, $30^{\circ}C$, and $40^{\circ}C$. The slump flow, arrival speed of 500 mm, and their changes with the elapsed time were found to bring the occurrence of rapid slump loss forward by about 30 minutes when increasing the temperature by $10^{\circ}C$ from $20^{\circ}C$. The initial and final setting times of the concrete at $20^{\circ}C$ were 7 hours and 12 hours, which were reduced by 1 hour and 3 hours at $30^{\circ}C$ and by 2 hours and 5 hours at $40^{\circ}C$, respectively. The hydration heat characteristics at $20^{\circ}C$ and $30^{\circ}C$ were similar in terms of the highest temperature of the concrete casting depth and the time when the maximum temperature occurred. However, at $40^{\circ}C$, the maximum temperature occurred about 4 hours earlier, and the highest temperature per the concrete casting depth increased by about $12^{\circ}C$. Therefore, it is concluded that the characteristics can vary according to the exterior temperature. Thus, quality assurance should consider workability, temperature cracks due to hydration heat, the properties of strength development, and other characteristics.

Performance Analysis of IGCC Gas Turbine Considering Turbine Operation Condition Change due to Modulation of Nitrogen Dilution (질소희석량 조절에 따른 터빈 운전조건 변화를 고려한 IGCC 용 가스터빈의 성능분석)

  • Kim, Chang Min;Kang, Do Won;Kim, Tong Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1023-1029
    • /
    • 2013
  • The integration between a gas turbine and an air separation unit (ASU) is important in IGCC plants. The portion of ASU air extracted from the gas turbine and the degree of nitrogen supply from the ASU to the gas turbine side are important operating parameters. Their effect on the gas turbine performance and operability should be considered in a wide ambient temperature range. In this study, appropriate nitrogen dilution rate and turbine inlet temperature that satisfy the two limitations of turbine blade temperature and maximum allowable power output were predicted. The air integration was set at zero. The simulation showed that the power output increases and turbine blade temperature decreases as the nitrogen dilution increases. The maximum allowable power output can be obtained under medium and low ambient temperature ranges. Under a high ambient temperature range, the achievable power is less than the maximum power.

Effects of Control Methods of Outdoor Air Cooling System on Energy Consumption in Building (외기냉방 시스템의 제어방법이 에너지 소비량에 미치는 영향에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4253-4259
    • /
    • 2015
  • In this study, the effects of various control methods of outdoor air cooling control system on control characteristics and energy consumption in building are researched by simulation. The system analysis modelling is done by using TRNSYS program package, and the control performances with existing outdoor air cooling methods are compared with the control ones without outdoor air cooling. As a result, appropriate operating temperature conditions of outdoor air cooling system according to outdoor temperature changes are required, and the outdoor air/return air dry bulb temperature comparison control method among the control methods shows best responses in energy savings.

The Influence of Wind Conditions on the Performance of Smoke Ventilation in High-rise Building Fires (초고층건물 화재시 외기바람이 배연성능에 미치는 영향)

  • Kim, Beom-Gyu;Yim, Chae-Hyun;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.63-73
    • /
    • 2016
  • This study examined the effects of the wind conditions, such as wind velocity and wind directions, on the performance of the mechanical smoke exhaust systems for high-rise building fires. A scaled model design and CFD simulations were used to verify the effects both quantitatively and qualitatively. The results showed that the smoke exhaust velocity of the mechanical exhaust system can be reduced by up to 17% at a wind velocity of 5 m/s (equivalent to an outdoor wind speed of 16 m/s) and a wind direction of ${\theta}=5^{\circ}$. In addition, the angle of the outdoor wind direction below ${\theta}=25^{\circ}$ had a significantly influence on the smoke exhaust flow rate and reduced exhaust performance of the smoke exhaust system in a fire.

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Performance Analysis of Hybrid Desiccant Chiller Based on Field Test (실증 실험을 통한 하이브리드 제습냉방 시스템의 성능 분석)

  • Ahn, Joon;Yun, Changho;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.621-627
    • /
    • 2013
  • Field tests of hybrid desiccant cooling systems were conducted from July to August 2011. Data were monitored and transferred in real time over the Internet. The monitored variableswere analyzed to determine the performance characteristics under outdoor conditions. A series of system simulations has been conducted for outdoor conditions of the field tests. The results agree well with the experimental data in general. The system performance has been shown to deteriorate for wetter conditions, as predicted by the simulation.

Experimental study on performance characteristics of heat pump chiller at heating conditions (히트펌프 칠러의 난방 운전시 성능특성에 관한 실험 연구)

  • Kim, Jung-Seok;Lee, Sang-Jae;Lee, Kwon-Jae;Lee, Soo-Kwang;Um, Yu-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1141-1144
    • /
    • 2010
  • 본 연구에서는 난방운전시 저온 및 착상 조건에서 히트펌프 칠러의 성능을 조사하고자 하였다. 실험은 항온항습 기능을 가진 공기엔탈피 방식의 칼로리미터와 항온수조를 사용하여 수행되었으며, 실외온도조건을 설정한 후에 히트펌프 칠러의 성능을 실험으로 측정하였다. 외기조건이 $-7^{\circ}C$에서 $-15^{\circ}C$까지 변화함에 따라 시스템의 성능과 COP는 표준온도 조건의 실험값 보다 약 48~87%까지 감소하였다. 착상 실험에서는 시간 변화에 따라 출구수온이 표준온도를 기준으로 74% 감소하였다. 본 연구로부터 히트펌프 칠러의 설계 기초자료 획득 및 신뢰성을 확인할 수 있었다.

  • PDF

Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System (중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6759-6765
    • /
    • 2015
  • In this study, the effects of control strategies of night-purge control system on control characteristics and energy consumption for central cooling system in building are researched by simulation. The start time and set-point temperature for night-purge control with outdoor temperature changes and building cold storage performance are obtained. The system analysis modelling is done by using TRNSYS program package, and the control performances with suggested night-purge control method are compared with the existing control ones. As a result, the suggested night-purge control method shows maximum 16.8% and 28.6% energy saving in comparison with existing control method and conventional one without night-purge control, respectively.