Analysis of the Harmonics on the Power Line in the Computer Room (전산실에서의 고조파 분석)

  • Roh, Deok-Nam;Eo, Ik-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6052-6059
    • /
    • 2012
  • This paper deals with the Harmonics on the power lines in the computer room. The voltage and current at each phase of electric power from UPS to the load must be ensured less than 5% distortion rates according to the regulation terms from KEPC(Korea Electric Power Corporation) and the KSC4310 Uninterruptible Power Supply regulation. However, measurements show that the voltage distortion rate conforms those regulations but the current distortion rate exceeds much the limit. This current distortion is stabilized from 34.98% to 15.22% nearly half by an AC current filter.

A Study on the Distortion Reducing of Output Voltage for UPS by Estimated Load Current (부하전류 예측에 의한 UPS의 출력전압 왜형률 개선에 관한 연구)

  • 변영복;박성준;추영배;권순재;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • The uninterruptible power supply (UPS) has become an integral part of modern computer and communication system to assure a continued and stable operation by providing an uninterruptible power to vital equipments. Various control methods have come to the fore in recent times with the advent of high frequency switching technologies. This paper describes the DSP control method for three phase UPS inverter which guarantees the sinusoidal output voltage under nonlinear load conditions. The proposed control scheme is verified by simulation and experiment.riment.

  • PDF

Measurement and Analysis of Power Quality on Elevator Equipments (승강기설비 전원의 전력품질 측정 및 분석)

  • Bang, Sun-Bae;Bae, Seok-Myung;Kim, Gi-Hyun;Lee, Kun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.83-86
    • /
    • 2005
  • 본 논문은 대단위 아파트를 주 대상으로 서울 7개소, 경기도 7개소, 강원도 10개소, 충청도 6개소, 총 30개소에 대한 승강기설비 전원품질을 측정하고 역률 변화, 고조파, 전압변동, 전압강하 등을 분석하였다. 분석결과 승강기설비 제어반 인입구에서의 실제역률(TPF)과 기본역률(DPF)의 차이가 고조파로 인하여 크게 나타나는 것을 확인하였고, 역률의 변화는 전원측(변압기)에 가까워질수록 작아지는 것을 확인하였다. 전압 종합왜형률(VTHD)은 안정적이지만 전류 종합왜형률(CTHD)은 기준치 이상의 매우 높은 수치가 발생되었고, 전원측(변압기)에 가까워질수록 작아지는 것을 확인하였다. 승강기설비 제어반 인입구에서의 전압강하율은 기준치 5%를 상회하고 있으나, 전압변동률은 최대 5.1%로서 기준치 10% 범위에 포함되었다.

  • PDF

A study on the measurements and analysis of harmonics obtained from each customers (수용가별 발생하는 전압, 전류고조파의 측정 및 비교 분석)

  • Yoon, Gi-Gab;Cho, Min-Ho;Kim, Sang-Jun;Jang, Sang-Ok;Ahn, Jeong-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.224-226
    • /
    • 2003
  • 본 논문에서는 현장측정을 통하여 수용가별(업무용, 주택용, 산업용)로 발생하는 전압, 전류고조파의 특성을 비교분석하였다. 특히 국내에서 규정되어 있지 않은 전류 고조파 종합왜형률($THD_i$)과 더 향상된 방식인 전류 종합 부하왜형률($TDD_i$)을 제시하여 $THD_i$와 비교하였다. 또한 50조파까지의 측정을 통해 향후 국내의 실정에 맞는 고조파 한계 기준에 적합한 설정치를 제시하였다.

  • PDF

Harmonic Reduction of Synchronous Generator by Permanent Magnet Shape Deformation (영구자석 형상 변형을 통한 동기발전기 고조파 저감)

  • Beom-Seok, Byeon;Eui-Jong, Park;Yong-Jae, Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1081-1088
    • /
    • 2022
  • The harmonics of synchronous generators increase iron and copper loss, which is the cause of fever. For harmonic reduction, the armature winding method is used as a distribution winding, a short pitch winding. In this paper, we want to improve the waveform of the instrument voltage by reducing the harmonics in a new way to the shape of the permanent magnet. The method cuts both ends of the permanent magnet and adjusts the air gap by increasing and decreasing the area according to the set value. By varying the distribution of magnetic flux density, the resulting electromotive voltage and strain were compared. This compares the shape-changing models of permanent magnets and shows an effective deformation method.

DSP Control of Three-Phase UPS Inverter with Output Voltage Harmonic Compensator (3상 UPS 인버터의 출력전압 왜형률 개선을 위한 고조파 보상기법의 DSP 제어)

  • 변영복;조기연;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.269-275
    • /
    • 1997
  • This paper presents real time digital signal processor(DSP) control of UPS system feeding processor(DSP) control of UPS system feeding nonlinear loads to provide sinusoidal inverter output voltage. The control scheme is composed of an rms voltage compensator, the load current harmonics feed-forward loop for the cancellation of output voltage harmonics, and the output voltage harmonics feedback loop for system stability. The controller employs a Texas Instruments TMS320C40GFL50 DSP.

  • PDF

An Analysis on the Effectiveness of Harmonics Reduction for Variable Frequency Drive by Reactors (리액터에 의한 가변주파수 구동장치의 고조파저감효과 분석)

  • Kim, Deok-Ki;Yoon, Kyoung-Kuk;Kim, Hee-Moon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.770-777
    • /
    • 2015
  • Recently, due to the rapid development of Power Electronics, the usage of Non Linear Load variable frequency drivers (VFDs) is increasing in the electric propulsion vessels and offshore plants. And harmonics which is generated by the variable frequency drives is an important issue should be solved. Ac line reactors and dc link reactors are widely used in variable frequency drives to improve the drive performance such as reducing input current harmonics, elevating input power factor, and protecting the drives from surges, etc. The effectiveness of both types of reactors in reducing input harmonics is affected by the loading of the drives and the system source impedance. And it considered that inductance of DC link reactors should be about 1.7 times of AC line reactors for same effect. The rules to evaluate the needs and effectiveness using ac line or dc link reactors are proposed for practical appications. In this paper, a simulation is performed to investigate of such factors using software PSIM.

THD Analysis of Output Current for Active Frequency Drift Method in Anti-islanding (능동적 주파수 변환기법의 출력전류 고조파 왜형율 분석)

  • Lee, Ki-Ok;Choi, Ju-Yeop;Choy, Ick;Yu, Gwon-Jong;An, Jin-Ung
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.7-12
    • /
    • 2010
  • As many grid-connected photovoltaic power conditioning systems (PVPCS)are installed in many residential areas simultaneously, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. In this paper, active frequency drift (AFD) method, one of the anti-islanding methods which is analyzed by current magnitude compensation and calculation of the fundamental component. Both harmonic component and RMS value of the output current for THD analysis are provided and verified by simulation.

New Control Method to Improve Total Harmonic Distortion of Critical Conduction Mode Boost Power Factor Correction (임계 도통 모드 부스트 역률 보상 회로의 전 고조파 왜형률 개선을 위한 새로운 제어 방법)

  • Yi, Je Hyun;Kim, Jung Won;Lee, Moon Hyun;Cho, Bo Hyung;Im, Jun Hyuk
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.199-200
    • /
    • 2014
  • 본 논문에서는 저 용량에서 많이 사용되는 임계 도통 모드 부스트 역률 보상 회로의 새로운 제어 방법을 제안한다. 제안하는 제어 방법은 임계 도통 모드로 동작 시에 회로의 주요 파형들을 수식적으로 분석하여 입력 전류가 입력 전압을 추종할 수 있는 최적의 온-시간을 도출하는 방식이다. 100W 급 하드웨어를 통하여 제안하는 제어 방법의 실험 결과를 검증하였다.

  • PDF

Space Voltage Vector PWM Modeling and Simulation Using Simulink (Simulink를 이용한 공간전압벡터 PWM 인버터 모델링 및 시뮬레이션)

  • 황재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.413-416
    • /
    • 2000
  • 본논문에서는 유도전동기 속도 및 토크 제어시 고조파의 왜형률을 감소시키고 디지털 구현이 용이하며 선형제어 영역을 증가시킬 수 있는 스위칭 방식으로 Space voltage Vector PWM(Pulse Width Modulation) 설명하였으며 시뮬레이션하기 위한 user_tool로써 Matlab/Simulink를 이용하여 SVPWM을 구현하는 방법을 설명하였다 결과적으로 개루프 운전 시 유도기에 인가되는 기준전압을 각각 비과변조와 과변조 시 전압비율 변경방식을 사용하여 나타나는 응답으로 가상스위칭 시간 T1, T2, T0 와 속도, 상전류, 토크응답을 알아보았다.

  • PDF