• Title/Summary/Keyword: 온도측정장치

Search Result 909, Processing Time 0.031 seconds

The Effect of the Histidine-Tryptophan-Ketoglutarate (HTK) Solution on Myocardial Protection in Isolated Rat Heart (흰쥐의 적출심장에서 HTK 용액의 심근보호 효과)

  • 송원영;장봉현;김규태
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.632-643
    • /
    • 2004
  • Background: The Histidine-Tryptophan-Ketoglutarate (HTK) solution has been shown to provide the excellent myocardial protection as a cardioplegia. The HTK solution has relatively low potassium as an arresting agent of myocardium, and low sodium content, and high. concentration of histidine biological buffer which confer a buffering capacity superior to that of blood.. Since HTK solution has an excellent myocardial protective ability, it is reported to protect myocardium from ischemia for a considerable time (120 minutes) with the single infusion of HTK solution as a cardioplegia. The purpose of this study is to evaluate the cardioprotective effect of HTK solution on myocardium when the ischemia is. exceeding 120 minutes at two different temperature (10 to 12$^{\circ}C$, 22 to 24$^{\circ}C$) using the Langendorff apparatus, Material and Method: Hearts from Sprague-Dawley rat, weighing 300 to 340 g, were perfused with Krebs-Henseleit solution at a perfusion pressure of 100 cm $H_2O$. After the stabilization, the heart rate, left ventricular developed pressure (LVDP), and coronary flow were measured. Single dose of HTK solution was infused into the ascending aorta of isolated rat heart and hearts were preserved at four different conditions. In group 1 (n=10), hearts were preserved at deep hypothermia (10∼12$^{\circ}C$) for 2 hours, in group 2 (n=10), hearts were preserved at moderate hypothermia (22∼24$^{\circ}C$) for 2 hours, in group 3 (n=10), hearts were preserved at deep hypothermia for 3 hours, and in group 4 (n=10), hearts were preserved at moderate hypothermia for 3 hours. After the completion of the preservation, the heart rate, left ventricular developed pressure, and coronary flow were measured at 15 minutes, 30 minutes, and 45 minutes after the initiation of reperfusion to assess the cardiac function. Biopsies were also done and mitochondrial scores were counted in two cases of each group for ultrastructural assessment. Result: The present study showed that the change of heart rate was not different between group 1 and group 2, and group 1 and group 3. The heart rate was significantly decreased at 15 minutes in group 4 compared to that of group 1 (p<0.05 by ANCOVA). The heart rate was recovered at 30 minutes and 45 minutes in group 4 with no significant difference compared to that of group 1. The decrease of LVDP was significant at 15 minutes, 30 minutes and 45 minutes in group 4 compared to that of group 1 (p < 0.001 by ANCOVA). Coronary flow was significantly decreased at 15 minutes, 30 minutes, and 45 minutes in group 4 compared to that of group 1 (p < 0.001 by ANCOVA). In ultrastructural assessment, the mean myocardial mitochondrial scores in group 1, group 2, group 3, and group 4 were 1.02$\pm$0.29, 1.52$\pm$0.26, 1.56$\pm$0.45, 2.22$\pm$0.44 respectively. Conclusion: The HTK solution provided excellent myocardial protection regardless of myocardial temperature for 2 hours. But, when ischemic time exceeded 2 hours, the myocardial hemodynamic function and ultrastructural changes were significantly deteriorated at moderate hypotherma (22∼ 24$^{\circ}C$). This indicates that it is recommended to decrease myocardial temperature when myocardial ischemic time exceeds 2 hours with single infusion of HTK solution as a cardioplegia.

Energy Loss of Hydrogen Atom due to Charge Exchange in Neutral Particle Energy Analyzer (중성입자 에너지 분석장치에서 전하교환용 탄소박막에 의한 수소원자의 에너지 손실특성)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.179-187
    • /
    • 1998
  • A neutral particle energy analyzer, which has the carbon stripping foil and the $90^{\circ}$ cylindrical electrostatic deflection plate, was designed and constructed for measuring of ion temperature in plasma. The energy calibration and energy resolution were studied in detail for a hydrogen ion at the $0.5{\sim}3.0\;keV$ energy using a duoplasmatron ion source. An energy of hydrogen ion to the deflection plate voltage at the peak ion count rate could be fitted by the expression $E_{o}(keV)$=3.83V(kV). The measured energy resolution, which was about 2 % at the energy of 3.0 keV and 9 % at the energy of 0.5keV, was better for the increased hydrogen ion energy. For the charge exchanged hydrogen atom due to the carbon stripping foil, the energy calibration, energy loss and resolution were measured to the $0.5{\sim}2.0{\mu}g/cm^{2}$ thickness of the carbon stripping foil. An energy of the charge exchanged hydrogen atom as a function of the deflection plate voltage and carbon foil thickness could be fitted by the expression $E_{o}(keV)=(0.53d+4.4){\cdot}V(kV)$. The energy loss was $0.23{\sim}0.89\;keV $ to the $0.5{\sim}2.0{\mu}g/cm^{2}$ carbon foil thickness and the $0.5{\sim}3.0\;keV$ energy of the incident neutral hydrogen atom, it could be fitted by the expression ${\Delta}E=(0.12d+0.27){\cdot}{E_{o}}^{1/2}(keV)$. The measured energy resolution for the neutral hydrogen atom, which was between 7 % and 35 % in this experiment region, was increased for the increasing neutral hydrogen atom energy and the decreasing carbon stripping foil thickness.

  • PDF

Oxide Films Formed on Hot-Dip Aluminized Steel by Plasma Electrolytic Oxidation and Their Films Growth Stages (플라즈마 전해 산화법에 의해 용융알루미늄도금 강판 상 형성한 산화층과 그 성장 과정)

  • Choe, In-Hye;Kim, Chang-Min;Park, Jun-Mu;Park, Jae-Hyeok;Hwang, Seong-Hwa;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.165-165
    • /
    • 2017
  • 지난 수 십 년 동안, 전 세계적으로 자원의 소비가 급격히 증가하게 되면서 최근 자원 고갈은 물론 환경오염이 커다란 이슈로 문제가 되고 있다. 이에 따라 재료 관련 분야에 있어서는 보다 효율적이고 친환경적인 방법으로 자원을 활용해야 된다는 필요성이 대두되었고 이와 같은 관점에서 목적하는 성분이 우수하고 환경 친화적인 표면처리 재료 개발연구가 활발하게 진행되고 있는 실정이다. 그 중 플라즈마 전해 산화(Plasma Electrolytic Oxidation, PEO)는 알루미늄, 마그네슘 등의 경금속의 경도를 향상시키고 높은 내마모성, 내식성을 갖게 하는 표면처리로써 그 관심이 증가하고 있다. 이 플라즈마 전해 산화는 일반적으로 공정비용 대비 효과적이고 환경 친화적이며 코팅 성능 면에서 우수하다고 알려져 있다. 이러한 고유한 특성으로 인해 플라즈마 전해 산화 코팅은 최근 몇 년 동안 기계, 자동차, 우주항공, 의학 및 전기 산업 등의 분야에서 그 적용이 점차 증가하고 있는 상황이다. 한편, 플라즈마 전해 산화 코팅을 하는 모재들의 경우 부동태 산화피막을 용이하게 형성할 수 있는 특성의 모재에 한정되고 있어서 그 응용확대에 한계가 있는 것이 사실이다. 따라서 본 연구에서는 플라즈마 전해 산화법을 사용하여 용융알루미늄도금 강판 상에 산화피막 형성을 시도하였다. 전원공급 장치의 양극은 전해질 속에 잠겨있는 작동전극에 연결하고 음극은 대전극 역할을 하는 스테인레스강 전해질 용기에 연결되었다. 전해질은 Sodium Aluminate 및 기타 첨가제를 함유한 것을 사용하였고 온도는 열교환기를 사용하여 $30^{\circ}C$ 이하로 유지되었다. 또한 여기서 전류밀도는 $5{\sim}10A/dm^2$, 실험 주파수는 700Hz, Duty cycle은 30 및 90%의 각 조건에서 공정처리 시간을 각각 30분 및 60분 동안 진행하였다. 이와 같은 조건에서 형성한 막들에 대해서는 주사형전자현미경(SEM)을 이용하여 코팅 막의 표면 및 단면의 모폴로지를 관찰하였음은 물론 EDS 및 XRD 측정을 통하여 원소조성분포 및 결정구조를 각각 분석하였다. 또한 이 코팅 막들에 대한 내식성은 5% 염수분무 환경 중 노출시험(Salt spray test), 3% NaCl 용액에서의 침지 시험 및 전기화학적 동전위 양극분극(Potentiodynamic Polarization) 시험을 진행하여 평가하였다. 이상의 실험결과에 의하면, 제작조건별 플라즈마 전해 산화 코팅 막의 모폴로지 및 결정구조가 상이하게 나타나는 것을 알 수 있었다. 코팅 막의 모폴로지 관찰 결과, 공정 시간에 비례하여 표면에 존재하는 원형 기공의 수는 감소하였으나 그 크기가 커지고 크레이터의 직경 또한 커진 것이 확인되었다. 이 기공은 마이크로 방전에 의해 형성된다고 알려져 있는데 공정 시간이 증가함에 따라 코팅 두께가 점차 증가하여 마이크로 방전의 빈도수가 줄어들고 그 강도는 증가하게 되어 기공 크기가 증가한 것으로 사료된다. 또한 공정시간이 긴 시편에서 표면에 크랙이 다수 존재하는 것으로 확인되었다. 이것은 방전에 의해 고온이 된 소재가 차가운 전해질과 만나게 되어 생긴 큰 온도구배로 인해 강한 열응력이 발생하여 균열을 초래한 것으로 보인다. 조성원소 분석 결과 원형 기공 주변의 크레이터 영역에는 알루미늄이 풍부하였으며 그 주변에 결절상을 갖는 구조에서는 전해질 성분의 원소가 포함되어 있는 것이 확인되었다. 이러한 코팅 막의 표면 특성은 내식성에 영향을 주게 된 원인으로 사료된다. 동전위 분극측정 결과에 의하면 플라즈마 전해 산화 공정 시간이 길어질수록 부식전류밀도가 증가하였다. 이것은 공정시간이 길어짐에 따라 강한 방전이 발생하여 기공의 크기가 증가하고 크랙이 발생하게 되면서 내식성이 저하된 것으로 판단된다. 종합적으로 재료특성 분석 및 내식성 평가를 분석한 결과, 플라즈마 전해 산화의 공정 시간이 너무 길게 되면 오히려 내식성은 저하되는 것이 확인되었다. 이상의 연구를 통하여 고내식 특성을 갖는 플라즈마 전해 산화 막의 유효성을 확인하였으며 용융알루미늄강판 상에 실시한 플라즈마 전해 산화 처리에 대한 기초적인 응용 지침을 제시할 수 있을 것으로 사료된다.

  • PDF

Effects of Biomass Gasification by Addition of Steam and Calcined Dolomite in Bubbling Fluidized Beds (기포유동층에서 수증기 및 소성된 백운석 첨가에 의한 바이오매스 가스화의 영향)

  • Jo, WooJin;Jeong, SooHwa;Park, SungJin;Choi, YoungTai;Lee, DongHyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.783-791
    • /
    • 2015
  • A fluidized-bed reactor with an inside diameter of 0.1 m and a height of 1.2 m was used to study the effect of steam and catalyst additions to air-blown biomass gasification on the production of producer gas. The equipment consisted of a fluidized bed reactor, a fuel supply system, a cyclone, a condenser, two receivers, steam generator and gas analyzer. Silica sand with a mean particle diameter of $380{\mu}m$ was used as a bed material and calcined dolomite ($356{\mu}m$), which is effective in tar reduction and producer gas purification, was used as the catalyst. Both of Korea wood pellet (KWP) and a pellet form of EFB (empty fruit bunch) which is the byproduct of Southeast Asia palm oil extraction were examined as biomass feeds. In all the experiments, the feeding rates were 50 g/min for EFB and 38 g/min for KWP, respectively at the reaction temperature of $800^{\circ}C$ and an ER (equivalence ratio) of 0.25. The mixing ratio (0~100 wt%) of catalyst was applied to the bed material. Air or an air-steam mixture was used as the injection gas. The SBR (steam to biomass ratio) was 0.3. The composition, tar content, and lower heating value of the generated producer gas were measured. The addition of calcined dolomite decreased tar content in the producer gas with maximum reduction of 67.3 wt%. The addition of calcined dolomite in the air gasification reduced lower heating value of the producer gas. However The addition of calcined dolomite in the air-steam gasification slightly increased its lower heating value.

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.

Weed and Pest Control by Means of Physical Treatments;Effect of infrared irradiation on loam for weed control (물리적인 방법을 이용한 잡초 및 병해충 방제 방법의 개발;적외선 조사에 의한 잡초방제를 위한 양토의 가열 효과)

  • Kang, Whoa-Seug;Yu, Chang-Yeon;Shin, Hyun-Dong;Kang, Wie-Soo;Oh, Jae-Heun
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.1
    • /
    • pp.91-104
    • /
    • 1996
  • The viability loss or death of weed seeds buried in soil can be induced by infrared irradiation which has good penetration in moist soil. By using this principle of pre-emergence soil-treatment, the study was carried out to obtain basic information needed to develop the effective weed control method for the production of less polluted agricultural products. An apparatus for irradiating infrared was constructed by using ceramic material with high emissivity. The LPG was used as fuel for producing infrared by heating ceramic material. The soil heated in this study was loam with four levels of moisture contents (0.6, 5.7, 10.7, 15.1 % wb). The temperature distribution was measured at various soil depths when soil with different moisture content was irradiated with infrared for three different times (30, 60, 90 sec). The soil depths with duration time of minimum 3 minutes over $80^{\circ}C$, temperature inducing viability loss of weed seeds, were investigated. When the moisture content of soil was 0.6 and 5.7 % wb, the soil depths which can induce viability loss of weed seeds was greatly increased with increasing irradiation time. However, any depths of soil tested in this study was not reached to the temperature of $80^{\circ}C$ when 30 seconds of irradiation time was applied on soil with moisture content of 10.7 or 15.1 % wb. Generally, the soil depth needed for viability loss of weed seeds was decreased with increasing moisture content of soil. Also, longer irradiation time was required to induce viability loss of weed seeds with increasing moisture content of soil.

  • PDF

Effects of heat treatment on the load-deflection properties of nickel-titanium wire (니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화)

  • Chang, Soo-Ho;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.349-359
    • /
    • 2006
  • Objective: Nickel-titanium alloy wire possesses excellent spring-back properties, shape memory and super-elasticity. In order to adapt this wire to clinical use, it is necessary to bend as well as to control its super-elastic force. The purpose of this study is to evaluate the effects of heat treatment on the load-deflection properties and transitional temperature range (TTR) of nickel-titanium wires. Methods: Nickel-titanium wires of different diameters ($0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ and $0.0215"\;{\times}\;0.028"$) were used. The samples were divided into 4 groups as follows: group 4, posterior segment of archwire (24 mm) without heat treatment; group 2, posterior segment of archwire (24 mm) with heat treatment only; group 3, anterior segment with bending and heat treatment; group 4, anterior segment with bending and 1 sec over heat treatment. Three point bending test was used to evaluate the change in load-deflection curve and obtained DSC (different scanning calorimetry) to check changes in $A_f$ temperature. Results: In the three point bending test, nickel-titanium wires with heat treatment only had higher load-deflection curve and loading and unloading plateau than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment had lower Af temperature than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment and bending had higher load-deflection curve than nickel- titanium wires with heat treatment and nickel-titanium wires without heat treatment. Nickel-titanium with heat treatment of over 1 sec and bending had the highest load-deflection curve. Nickel-titanium wires with heat treatment and bending had lower Af temperature, Nickel-titanium wires with heat treatment of over Af sec and bending had the lowest Af temperature. Conclusion: From the results of this study, it can be stated that heat treatment for bending of Nickel-titanium wires does not deprive the superelastic property but can cause increased force magnitude due to a higher load-deflection curve.

Studies on the Pasteurization Conditions of Takju (탁주의 저온 살균조건에 관한 연구)

  • Lee, Cherl-Ho;Tae, Won-Taek;Kim, Gie-Myung;Lee, Hyun-Duck
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.44-51
    • /
    • 1991
  • The thermal resistance of the important microorganisms in takju. Korean traditional turbid alcoholic beverage, was measured and optimun heating time and temperature to achieve the commercial pasteurization of these microorganisms were examined. Most of the vegetative bacterial cells in takju were destroyed by heating at over $60^{\circ}C$, except for the spore forming organisms, which did not actively grow in takju after pasteurization. The important microorganisms for the quality deterioration of pasteurized takju were then appeared to be yeast and molds, and their thermal resistances were measured. The thermal resistances of these microorganisms changed greatly depending upon the heating method. The D values of yeast in takju were 3.5 min at $65^{\circ}C$ and 0.46 min at $80^{\circ}C$ in cap-tube, and 7.1 sec at $65^{\circ}C$ and 2.3 sec at $80^{\circ}C$ in a continuous coil heat exchanger. Those of molds were 2.7 min at 65℃ and 0.25 min at $80^{\circ}C$ in cap-tube, and 3 sec at $65^{\circ}C$ and <1 sec at $80^{\circ}C$ in the coil heat exchanger. The acidity and pH did not change at $30^{\circ}C$ for two weeks after pasteurization by heating in the coil heat exchanger at $65^{\circ}C$ for 17 sec, but the viscosity increased slightly by the heat treatment. Significant differences in sensory quality, especially the formation of burnt smell and bitterness by heating takju for 12D of yeast at $70,\;80\;and\;85^{\circ}C$, respectively, were observed and this resulted in the significant reduction in overall likeness of pasteurized takju. However, when the heating temperature was fixed to $80^{\circ}C$, the overall likeness of pasteurized takju did not affected significantly by the heating time ranging from 8D to 12D of yeast. It was concluded that the optimum pasteurization condition of takju in a continuous heat exchanger was heating at $80^{circ}C$ for 23sec(10D of yeast).

  • PDF

Improvement of Radiosynthesis Yield of [11C]acetate ([11C]아세트산의 방사화학적 수율 증가를 위한 연구)

  • Park, Jun Young;Son, Jeongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.74-78
    • /
    • 2018
  • Purpose $[^{11}C]$acetate has been proved useful in detecting the myocardial oxygen metabolism and various malignancies including prostate cancer, hepatocellular carcinoma, renal cell carcinoma and brain tumors. The purpose of study was to improve the radiosynthesis yield of $[^{11}C]$acetate on a automated radiosynthesis module. Materials and Methods $[^{11}C]$acetate was prepared by carboxylation of grignard reagent, methylmagnesium chloride, with $[^{11}C]$$CO_2$ gas, followed by hydrolysis with 1 mM acetic acid and purification using solid phase extraction cartridges. The effect of the reaction temperature ($0^{\circ}C$, $10^{\circ}C$, $-55^{\circ}C$) and cyclotron beam time (10 min, 15 min, 20 min, 25 min) on the radiosynthesis yield were investigated in the $[^{11}C]$acetate labeling reaction. Results The maximum radiosynthesis yield was obtained at $-10^{\circ}C$ of reaction temperature. The radioactivities of $[^{11}C]$acetate acquired at $-10^{\circ}C$ reaction temperature was 2.4 times higher than those of $[^{11}C]$acetate acquired at $-55^{\circ}C$. Radiosynthesis yield of $[^{11}C]$acetate increased with increasing cyclotron beam time. Conclusion This study shows that radiosynthesis yield of $[^{11}C]$acetate highly dependent on reaction temperature. The best radiosynthesis yield was obtained in reaction of grignard reagent with $[^{11}C]$$CO_2$ at $-10^{\circ}C$. This radiolabeling conditions will be ideal for routine clinical application.

Stress Variation Characteristics of Temporary Fixed Steel Rod in FCM Bridge Construction Method (FCM 교량 가설 공법에서 임시 고정 강봉의 응력 변화 특성 )

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.21-29
    • /
    • 2023
  • In this study, the stress characteristics of temporary fixed steel rods were analyzed in the "temporary fixing system using internal prestressing tension", which is mainly applied to the construction of superstructures by FCM. It was difficult to confirm the changes in initial tensile force in this system because the steel rod was internally connected to the pier and the PSC BOX. Therefore, measurement was performed before and after the completion of each segment using an FBG sensor to measure the change in the micro length of the steel rod. The results of the analysis showed that 75% to 90% of the maximum vertical contraction of the steel rod that occurred until the completion of the cantilever segment occurred in the fixing ~ 1segment, and the maximum loss of initial prestressing force was 39%. Such excessive loss of tension force to 1 segment means that tension is needed to improve the precision of construction during the fixation, and re-tension is needed to secure stability for conduction of cantilever segments after the completion of 1segment. In the 2 ~ last segment, the stress of the steel rod decreased gradually, and in the summer, the decrease in stress tended to partially recover due to the increase in the length of the steel rod corresponding to the increase in the vertical volume of PSC BOX. The dominant factor in the stress change in 2~ last segment in this phenomenon is judged to be the change in the length of the steel rod according to the temperature. Unlike the change in length, the relaxation was 1.2-2.7%, which was mostly offset by the opposite stress corresponding to the temperature stress. Therefore, a plan was proposed to improve the internal stress, such as adjusting the fixation time.