• Title/Summary/Keyword: 온도분포특성

Search Result 1,447, Processing Time 0.033 seconds

Computational Analysis of Air Flows Inside Korean Traditional House (친환경 전통건축의 내부기류 전산해석)

  • Kim, Jay-Won;Aan, Eun-Yeong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.3
    • /
    • pp.380-387
    • /
    • 2012
  • The present investigation is to examine the thermal behaviors of air flows inside Korean traditional house made of the construction materials transmitted. The methodology is numerical predictions of air flows depend on the temperature distribution inside the indoor spaces. The transient computational simulations are performed along with the different house types, weather condition, and operating time. Thermal properties of building units have been obtained by the parallel measurements and utilized in the numerical works. Consequently, the details of flows and temperature of air in the houses illustrate the thermal design of the traditional Korean house satisfy the requirements of human living.

Indoor Air Temperature Distribution in a Floor Heating Space with PCM Panels (잠열저장패널이용 바닥난방공간의 실내온도분포에 관한 연구)

  • Cho, Soo;Sohn, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.59-71
    • /
    • 1992
  • The purposes of the present study are to investigate the characteristics of heat storage and emission of the PCM($CalCl_2{\cdot}6H_2O$) panel, and to analyze the distribution of indoor air temperature in a floor heating space with PCM panels for the heating system. Two identical unit test cells sized $1.8m^W{\times}1.8m^L{\times}1.8m^H$ were built and installed with specially designed aluminium Ondol-panels. It held 1.2kg of calcium chloride hexahydrate(CCH). It was found that PCM panels could reduce the indoor air temperature fluctuations and maintain the phase changing temperature for considerably long duration, $2{\sim}3$ times longer in heating hour over no-CCH one. When the elapsed time was 6 hours, the average temperature difference between PCM panel and Ondol panel was $7.7^{\circ}C$.

  • PDF

Distribution of Grown-in Defects in the Fast-pulled Czochralski-silicon Single Crystals (고속 인상 초크랄스키 실리콘 단결정에서 성장 결함 분포)

  • 박봉모;서경호;오현정;이홍우;유학도
    • Korean Journal of Crystallography
    • /
    • v.14 no.2
    • /
    • pp.84-92
    • /
    • 2003
  • The fast pulling is easy to modify the distribution of grown-in defects toward fine size, which can be readily removed by additional treatment. In this experiment, The fast pulled crystals with high pulling late over 1.0 mm/min were grown and their grown-in defect distributions were investigated. In our recent developments in the growth of Cz-Si, it could be found that the cooling rate in a specific temperature range and the uniformity of temperature gradient at solid/liquid interface are more important for the formation of grown-in defect than the pulling rate itself. We analyzed these cooling rates and temperature gradients for the various fast pulled crystals and compared them to the observed formation behavior of the grown-in defects. The effective factor (Ω) for the void defect formation was introduced and it could explain the radial distribution of void defects in the fast-pulled crystals effectively.

A Physioclimatic Study on the Thermal Sensation in Korea (한국의 열감분포에 관한 생리 기후학적 연구 - 신유효온도를 중심으로 -)

  • 강철성
    • Journal of the Korean Geographical Society
    • /
    • v.32 no.2
    • /
    • pp.129-140
    • /
    • 1997
  • The purpose of this paper is to analyze thermal sensation which is measured bv human physioclimatic reactions in Korea. Human physiological reactions to temperature and relative humidity are analyzed to produce a nomogram from which average human reactions to the climatic factors can be deduced. Thermal - indices for each regular stations in both South (1961-1990) and North Korea(1973-1994) are calculated based on monthly meteorological data. A generalized annual physioclimatic maps for each Annual Cumulative Thermal Index for the 52 stations are constructed to show how men tend to feel in various areas. Resuts of this study can be applied for evaluation of thermal environment in our daily activities, and for searching relevant sports training-sites.

  • PDF

Multi-dimensional Fire Behaviors in an Under-ventilated Compartment Fire (환기부족 구획화재에서 다차원 화재거동)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.37-42
    • /
    • 2010
  • 실제 규모 ISO 9705 표준 화재실에서 과환기(over-ventilated) 및 환기부족(under-ventilated) 화재에 대한 열 및 화학적 특성에 관한 실험이 수행되었다. 또한 FDS(Fire Dynamic Simulator)를 이용하여 수치적 예측성능에 대한 평가와 환기부족화재에서 건물 내부의 다차원 화재현상에 대한 해석이 이루어졌다. 과환기 및 환기부족화재의 특성은 연소효율, 총괄 당량비 뿐만 아니라 고온 상층부의 온도분포, 연소 생성물의 농도에 의해 명확하게 구분되었다. 실험결과와의 비교를 통해 과환기 및 환기부족화재에서 FDS는 공간내부의 온도, 열유속 및 다양한 화학종의 분포를 정량적으로 잘 예측함을 확인하였다. 과환기화재와 비교할 때, 환기부족화재에서 내부유동은 반대방향의 다차원 재순환 유동구조를 갖고 있음을 발견하였다. 동시에 공간내부의 $O_2$ 및 CO의 분포 역시 다차원 구조를 갖기 때문에 기존화재연구에서 측정되는 고온 상층부의 열 및 화학적 특성은 환기부족화재를 이해하는데 많은 한계가 있음을 확인하였다.

  • PDF

Estimating Spatio-Temporal Distribution of Climate Factors in Andong Dam Basin (안동댐 유역 기상인자의 시공간분포 추정)

  • Lim, Chul Hee;Moon, Joo Yeon;Lim, Yoon Jin;Kim, Sea Jin;Lee, Woo Kyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.4
    • /
    • pp.57-65
    • /
    • 2015
  • This study investigates characteristics of time series spatial distribution on climate factors in Andong Dam basin by estimating precise spatio-temporal distribution of hydro-meteorological information. A spatio-temporal distribution by estimating Semi-Variogram based on spatial autocorrelation was examined using the data from ASOS and 7 hydro-meteorological observatories in Andong Dam basin of upper Nakdonggang River, which were installed and observed by NIMR(National Institute of Meterological Research). Also, temperature and humidity as climate variables were analyzed and it was recognized that there is a variability in watershed area by time and months. Regardless of season, an equal spatial distribution of temperature at 14 o'clock and humidity at 10 o'clock was identified, and nonequal distribution was noticed for both variables at 18 o'clock. From monthly spatial analysis, the most unequal distribution of temperature was seen in January, and the most equal distribution was detected in September. The most unequal distribution of humidity was identified in May, and the most equal distribution was seen in January. Unlike in forest, seasonal spatial distribution characteristics were less apparent;but temperature and humidity had respective characteristics in hydro-meteorology.

여름철 낙뢰 발생 시 강수 및 위성의 휘도온도 특성

  • Lee, Yun-Jeong;Seo, Myeong-Seok;O, Seok-Geun
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.38-39
    • /
    • 2010
  • 낙뢰란 뇌운 속에서 분리 축적 된 음 (-)과 양 (+)의 전하 사이 또는 뇌운 속의 전하와 지면에 유도되는 전하 사이에서 발생하는 불꽃 방전을 말한다. 뇌운 안에는 이 불꽃 방전을 반복하기에 충분한 전하의 분리가 계속 일어나고 있는데, 그 결과 양전하 (+)는 구름의 상부에 넓게 분산되어 분포하고, 음전하 (-)는 주로 구름 하부에 분포한다. 이 때 음전하가 대지로 방전되어 발생하는 낙뢰를 부극성 (-)낙뢰, 양전하가 대지로 방전되어 발생하는 낙뢰를 정극성 (+)낙뢰라 한다. 낙뢰의 약 80%는 구름 내부 또는 구름 대 구름 사이에서 발생하고, 약 20%만이 구름과 지면 사이에서 발생하는데, 이러한 구름-지면 낙뢰 (Cloud-to-ground lightning)는 가장 위험하고 그 피해도 크다. 우리나라는 동아시아 몬순 기후의 영향으로 여름철에 대기가 불안정하여 낙뢰가 집중적으로 발생하며, 복잡한 지형과 해양의 영향으로 낙뢰현상의 공간적 변동도 크게 나타난다. 이러한 낙뢰는 최근으로 올수록 강도가 증가하고 있어 그 피해의 증가가 우려되기 때문에 낙뢰 발생 특성에 대한 연구가 필요하다. 본 연구에서는 낙뢰자료와 강수자료, 그리고 시 공간 분해능이 뛰어난 MTSAT-1R (Multi-functional Transport SATellite - 1 Replacement) 정지궤도 위성의 휘도온도를 이용하여 낙뢰 발생 시 강수 및 위성 휘도온도의 특성을 분석하고자 한다. 이러한 연구는 대류활동에 대한 정보 제공 뿐 아니라, 낙뢰 예측성 향상 및 재해 경감에도 활용될 수 있을 것이다. 본 연구에서는 2001년 기상청에 도입되어 운영 중인 신 낙뢰관측 시스템 (Total Lightning Detection System, TLDS)에서 관측된 낙뢰자료와 MTSAT-1R 위성에서 관측된 휘도온도 자료, 그리고 자동기상관측장비 (Automatic Weather System, AWS)에서 관측된 강수자료를 사용하였으며, 세 자료의 출처는 모두 기상청이다. 분석 기간은 2006년부터 2007년까지이며 우리나라에서 낙뢰발생 빈도가 여름철에 집중되어 나타나는 것을 고려하여 여름철 (6~8월) 낙뢰에 대해서만 분석하였다. 또한 낙뢰 발생 사례에 대하여 관측 효율이 90% 이상으로 알려진 위도 $33{\sim}39^{\circ}N$, 경도 $124{\sim}130^{\circ}E$ 영역에서 낙뢰발생시 강수 및 위성 휘도온도의 특성을 분석하였다. 사례는 낙뢰 발생 횟수가 많은 날을 중심으로 먼저 적외영상과 낙뢰영상을 정성적으로 분석한 후 뇌우의 지속시간이 긴 9개 사례를 선정하였다. MTSAT-1R 위성과 낙뢰자료 및 강수자료는 관측주기와 공간규모가 서로 다르기 때문에 세 자료를 함께 사용하기 위해서는 시 공간을 일치시키는 과정이 필요하다. 본 연구에서는 위성자료 관측시간(00분, 33분)과 AWS 지점 위 경도를 시 공간 일치를 위한 기준으로 사용하였다.

  • PDF

Thermal distribution change in polyvinyl alcohol gel caused by focused ultrasound (폴리비닐알코올 젤의 집속초음파에 의한 온도분포 변화)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.576-584
    • /
    • 2020
  • In order to obtain basic information for using polyvinyl alcohol (PVA) gel as a tissue mimicking phantom for temperature visualization, the temperature change characteristics due to the focused ultrasound were examined for different concentration of PVA. To obtain the basic acoustic characteristics, the speed of sound, the attenuation coefficient, and the density depending on the PVA concentration were measured, and the thermodynamic characteristics, such as thermal conductivity and heat capacity, were measured. The range of temperature rising in the vicinity of the focal point due to the focused ultrasound was observed using a thermochromic film that changes color at 30 degree or more, and the discolored area was obtained by image processing of the recorded image. As the concentration of PVA increases in the given range of 2 wt% ~ 16 wt%, the area that rises above 30 degree inside the gel increases linearly. It is confirmed that the discolored area increases as the power applied to the focused ultrasonic transducer increases. These results showed good agreement with the simulation results using the finite element method.

Study on the Cooling Characteristics of Distribution Transformer by Using Vegetable Oil (식물성 절연유를 적용한 배전급 유입 변압기의 냉각 특성 연구)

  • Hong, Dong-Jin;Kim, Chul-Sook;Kim, Joong-Kyoung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1139-1140
    • /
    • 2011
  • 식물성 절연유는 기존에 사용되던 광유와 비교하여 우수한 생분해성 및 뛰어난 난연 특성을 가지고 있다. 반면에 광유 대비 높은 점도로 인하여 냉각 효과가 떨어지기 때문에 효과적인 사용을 위해서는 변압기 내부 온도 상승에 따른 특성 검토가 필요하다. 본 연구에서는 배전급 유입변압기에 대하여 광유와 식물성 절연유의 내부 온도 분포 특성 비교를 위한 시제품을 제작하여 실제 내부 온도를 측정하고 3차원 해석을 통하여 광유와 절연유의 열적 특성을 비교하였다.

  • PDF

핵연료봉 주위의 난류 유동장 특성에 대한 연구 현황과 검토

  • 이계복;장호철;권혁성;이상근
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.292-299
    • /
    • 1993
  • 원자로 노심내 핵 연료봉의 정확한 온도 분포를 구하기 위해서는 핵 연료봉 주위의 난류 유동장에 대한 해석이 필요하다. 난류 유동장의 특성을 파악하기 위해 실험적 연구와 해석적 방법에 의한 연구가 함께 수행되고 있다. 본 기고문은 현재까지 보고된 난류 유동장의 특성을 알아보고 해석적 방법의 연구 동향과 문제점을 분석하여 이 분야에 대한 연구 활동에 도움이 되고자 한다.

  • PDF