• Title/Summary/Keyword: 온도변화폭

Search Result 553, Processing Time 0.025 seconds

A compensation method for a temperature-dependent gain tilt in L-band EDFA using a voltage-controlled attenuator (L-band EDFA 에서의 온도에 따른 이득 변화와 가변 감쇄기를 이용한 온도 보상)

  • 이원경;정희상;주무정
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.12-16
    • /
    • 2003
  • This paper presents a compensation method for a temperature-dependent gain tilt in L-band erbium-doped fiber amplifier using a voltage-controlled attenuator. The gain tilts in the L-band of 1570-1605 nm due to a temperature change have negative slopes, whereas they have positive slopes for the increasing optical input powers in a saturation region. The proposed method utilizes these opposite gain variations to compensate for the gain tilt over a wide range of temperature. While applying forty channels with a channel spacing of 100 GHz in the L-band and changing the ambient temperature from 0 to $50^{\circ}C$, the compensation method maintained the gain deviation within 1 dB.

C-V 측정을 통한 다이오드 소자의 온도 특성 분석

  • Choe, Pyeong-Ho;Kim, Sang-Seop;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.284-284
    • /
    • 2012
  • 본 연구에서는 다이오드 소자의 온도 증가에 따른 C-V 특성을 분석하였다. 180 kHz 주파수 조건에서 온도는 300 K에서 450 K까지 50 K 간격으로 가변하였다. 측정 결과 reverse bias 영역에서는 커패시턴스의 온도 의존성이 없었으나, forward bias 영역에서는 온도가 증가함에 따라 동일 전압에서의 커패시턴스가 증가하였다. 이로부터 온도가 증가 할수록 소자가 반전(inversion) 상태에서 축적(accumulation) 상태로 빨리 전환함을 확인하였으며, 1/C2-V 그래프로부터 온도 증가에 따른 전위장벽(Built-in potential, Vbi) 감소를 확인하였다. 전위장벽은 0.63 V에서 0.31 V로 온도 상승에 따라 약 0.1 V씩 감소하였다. 이는 energy band diagram에서 p-type 영역과 n-type 영역의 energy band 차가 감소해 공핍층 영역의 폭이 좁아짐을 의미한다. 공핍층의 두께 감소로 다이오드 전류의 급격한 증가뿐 아니라 위에서 언급한 바와 같은 C-V 특성을 보였다. 이번 연구에서는 기존의 보편화 된 I-V 측정을 통한 다이오드 소자 분석과는 달리 온도 변화에 따른 C-V 분석을 통해 소자 내부의 전위 장벽 및 공핍층 폭 감소에 따른 소자 특성 변화를 분석하였다.

  • PDF

Behavior and Design of Terminal Joint Width between Post-Tensioned Concrete Pavement and Jointed Concrete Pavement under Temperature Changes (온도변화에 따른 PTCP와 JCP 접속부 줄눈 폭 변화와 설계 방안)

  • Kim, Dong-Ho;Lee, Bong-Hak;Kim, Seong-Min;Park, Seong-Tae
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.223-228
    • /
    • 2011
  • The initial joint width design of the terminal joint between post-tensioned concrete pavement (PTCP) and jointed concrete pavement (JCP) was studied in this research. The joint width between PTCP and JCP directly affects noise and ride quality. If the initial joint width is very large, noise increases and ride quality decreases. If the initial joint width is very small, on the other hand, under high temperatures, PTCP slabs can blow up, or failures near the joint can occur due to excessive compressive stresses. The terminal joint width behavior between PTCP and JCP near Jumunjin at Donghae expressway under temperature changes was measured in August and November 2010 and the data was analyzed. From this study, the design methodology of the optimal initial terminal joint width was proposed.

Joint Width Design for Post-Tensioned Concrete Pavement (포스트텐션 콘크리트 포장의 줄눈 폭 설계)

  • Kim, Dong-Ho;Kil, Yong-Su;Kim, Jin-Woung;Yun, Kyeong-Ku
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.147-154
    • /
    • 2010
  • In post-tensioned concrete pavement(PTCP), one of the most important design variables is the initial joint width, in addition to the tensioning spacing. The joint width between PTCP slabs directly affects noise and ride quality. If the joint width is too wide, noise increases and ride quality decreases. If the initial joint width is too narrow, on the other hand, under high temperature, PTCP slabs can blow up, or failures near the joint can occur due to excessive compressive stresses. This study was conducted to determine the optimal initial joint width of PTCP and to investigate the joint width behavior under temperature changes. The experiments were performed using one-year-old PTCP slabs. The concrete temperatures were measured using the temperature measurement sensors installed at various depths. The joint widths were measured using vernier-calipers at different times of a day and the relationship between the joint width and temperature was analyzed. From this study, the design methodology to determine the optimal initial joint width of PTCP could be proposed.

The study on the physiological response and comfort in wearing sportswear in Raniy environments (강우환경 하에서의 스포츠웨어 착용시 인체생리반응 및 쾌적감)

  • 권오경;김진아
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.194-199
    • /
    • 2001
  • 쾌적한 스포츠웨어는 기능성에 있어서 자연환경의 변화조건과 인체의 운동 및 활동에 맞추어 열절달 및 수분전달 등을 적절히 조절할 수 있어야 한다. 이에 본 연구에서는 일반환경조건 및 강우환경조건하에서의 형상기억 투습방수직물 소재의 스포츠웨어 착용에 따른 인체생리반응 및 쾌적감을 규명하기 위하여 스포츠웨어를 제작하여, 인공기후실에서 환경조건변화에 따른 온열생리학적 특성 및 주관적 감각을 측정, 그 특성을 비교, 고찰하였다. 평균피부온은 강우환경조건에서 온도가 낮게, 변동폭이 많게 나타났다. 변화경향을 운동부하를 기점으로 온도의 상승이 나타났고, 운동 2단계에 가장 높은 온도를 나타냈으며, 이후 감소하였다. 직장온은 일반환경조건에 비해 강우환경조건에서 온도의 미세한 상승을 보였다. 의복내 기후는 두 조건 모두에서 가슴부위보다 등부위의 온·습도의 변동폭이 크게 나타났고, 강우환경조건에서의 의복내 온도를 제외하고는 모두 등부위의 온·습도가 높게 나타났다. 최고 혈압은 운동의 강도에 따라 비례하여 상승하고, 최저 혈압에는 큰 영향없이 나타났으며, 변화경향은 의복내 온도의 경향과 역으로 나타났다. 평균혈압은 일반환경조건에서 6.9mmHg 높게 나타났다. 심박수는 일반환경조건에서 4.4beats/min 높게 나타났다. 강우환경조건의 주관적 감각의 평가에서, 신체에 직접 가해지는 빗물 등으로 인해 불쾌감이 증가하였고, 운동 후에는 일반환경조건과 달리 냉감이 증가하였으며, 습윤감은 최고치에 달하였다.

  • PDF

Quality Changes as affected by Storage Temperature and PP Film Packaging on 'Sirocco' Paprika on Hydroponic (수경재배한 파프리카 '시로코' 저장온도별 PP필름 개별포장 따른 수확 후 특성 변화)

  • Jung-Soo Lee
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.59-65
    • /
    • 2023
  • The aim of this study was to examine the effect of packaging on the quality maintenance of paprika (Capsicum annuum L. cv. Sirocco) stored at three different temperatures. Paprika was either unpacked (control) or packed with individual PP (propylene) film and stored at 10℃ and 20℃ for 30 days. Quality characteristics such as weight loss and appearance were examined. Paprika packed with PP film at 10℃ showed fewer quality changes compared to unpacked paprika stored at the other temperatures. Commercial properties tended to decrease rapidly during storage at 20℃ with unpacked paprika. The degree of fresh weight loss was significantly lower in packed paprika at 10℃ compared to unpacked paprika stored at other temperatures. It was found that general appearance, soluble solids content, and hardness were complexly affected by storage temperature and PP film packaging. A storage temperature of 10℃ was effective in maintaining freshness, and paprika packed in PP film maintained greater freshness than unpacked paprika. Our results showed that packaging is necessary to preserve the freshness and improve the marketability of paprika in the domestic market.

Histologic Effects of a Contact Diode Laser on Intraoral Soft Tissue (접촉식 다이오드레이저조사가 구강연조직에 미치는 조직학적 영향)

  • White, Joel M.;Shin, Keum-Back;Thompson, Rick;Myers, Terry D.
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 1998
  • 본 연구는 두 가지 관점, 즉 다이오드레이저를 구강연조직에 접촉식으로 조사하여 조직을 절제할 경우 첫째 심부조직에서의 온도 상승 정도에 대한 분석 평가, 둘째 절제에 따른 조직의 열적 응고에 대한 조직학적 분석 평가를 위해 시도되었다. 연구를 위해 도축된 소의 혀 배면으로부터 5.0mm깊이에 T형 열전대(type T thermocouple)를 설치하고 조사조건에 따른 레이저절제 도주의 온도변화를 측정하고, 또한 해당조사부위의 조직을 대상으로 통법에 의한 H-E염색 후 조직학적 측면에서 열적 응고상을 검색하여 Nd:YAG레이저의 경우에서와 비교하였다. 즉 파장815nm의 다이오드레이저를 0-10W의 출력, 50Hz와 연속파의 주파수조건에서 접촉식으로 조사하였으며, 또한 파장1064nm의 Nd:YAG레이저를 0-10W의 출력, 50Hz와 100Hz의 주파수 조건에서 접촉식으로 조사하였다. 레이저의 접촉조사시 레이저광섬유 첨단부에서 10(10gm의 일정한 압력과 25mm/sec의 이동속도로 조직을 절제하였다. 레이저가 접촉조사된 조직부위를 통법에 의해 조직학적으로 H-E염색을 시행하였으며, 계측현미경을 이용하여 10배율 아래에서 조직절제의 폭과 깊이, 측방 및 하방 쪽으로 열적 응고의 폭을 계측하였다. 계측치에 대한 통계학적 처리결과 조직절제의 폭과 측방쪽으로 열적응고의 폭은 다이오드레이저에와 Nd:YAG레이저에서 같은 정도를 나타냈다. 조직절제의 깊이는 Nd:YAG레이저에서에 비해 다이오드레이저에서 더 깊었다. 하방쪽으로의 열적응고의 폭은 Nd:YAG레이저를 10Hz의 조건에서 조사한 경우에서 가장 넓었으며, 다이오드레이저를 50Hz와 연속파의 조건에서 조사한 경우에서 가장 좁았다. 레이저절제 도중 심부조직에서의 온도변화는 다이오드 레이저에서와 Nd:YAG레이저에서 모두 출력이 증가함에 따라 상승되었으며, 다이오드레이저에서 보다 Nd:YAG레이저에서 더 높이 상승되었다. 결론적으로 본 연구에서 시도된 조사조건 범위 이내에서는 구강연조직 절제시 다이오드레이저가 펄스형 광섬유 전달식 Nd:YAG레이저 보다 심부조직에서의 낮은 온도상승과 하방쪽으로의 좁은 열적 응고의 폭을 보이면서 우수한 조직절제효과를 나타냈다.

  • PDF

Quality Changes of Hydroponically Grown 'New Raon Red' Paprika Packaged in Corrugated Box as Affected by Storage Temperature (수경재배한 미니 파프리카 '뉴라온레드' 저장온도 별 골판지박스 포장에서 수확후 특성 변화)

  • Chul Geon An;Jung-Soo Lee
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.35-41
    • /
    • 2023
  • The purpose of this study was to examine the effect of each storage temperature condition of 5, 10, 15 and 20℃ to maintain the freshness of mini paprika (Capsicum annuum cv. New Raon Red) in corrugated box. Changes in general appearance, fresh weight loss, firmness, SSC (solid sugar content), and Hue angle were investigated. Furthermore, storage at temperatures ranging from 5℃ to 15℃ for 14 days resulted in maintaining freshness for 35 days. Paprika stored at 20℃ showed significantly higher loss of fresh weight and firmness than that of other storage temperatures. Furthermore, paprika stored at 5℃ and 10℃ showed a lesser decrease in hue angle than that at 15℃ and 20℃. However, the SSC of mini paprika was not significantly affected by storage temperature. These results suggest that corrugated box packaging in combination with low storage temperatures (5~10℃) could be effective in prolonging the shelf life of mini paprika. Therefore, the results represented that the low temperature storage in combination with cardboard box treatment could be effective in prolonging the shelf life of fresh paprika.

Time-resolved Photoluminescence Study of Seven-stacked InAs/InAlGaAs Quantum Dots

  • O, Jae-Won;Gwon, Se-Ra;Ryu, Mi-Lee;Jo, Byeong-Gu;Kim, Jin-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.265-265
    • /
    • 2011
  • 자발형성법으로 InP (001) 기판에 성장한 InAs/InAlGaAs 양자점(QDs: quantum dots)의 광학적 특성을 PL (photoluminescence)와 TRPL (time-resolved PL)을 이용하여 분석하였다. InAs QDs 시료는 single layer InAs QDs (QD1)과 7-stacked InAs QDs (QD2)를 사용하였다. 두 시료 모두 저온 (10 K)에서 1,320 nm에서 PL 피크가 나타나고, 온도가 증가함에 따라 PL 피크는 적색편이 (red-shift)를 보였다. 양자점의 온도를 10 K에서 300 K까지 증가하였을 때 QD1은 178 nm 적색편이 하였으며, PL 스펙트럼 폭은 온도가 증가함에 따라 증가하였다. 그러나 QD2는 264 nm 적색편이를 보였으며 PL 스펙트럼의 폭은 QD1 시료와 반대로 온도가 증가함에 따라 감소하였다. QD2의 아주 넓은 PL 스펙트럼 폭과 매우 큰 적색편이는 InAs 양자점 크기의 변화가 QD1에 비해 훨씬 크기 때문이다. QD2의 경우 InAs 층수(layer number)가 증가함에 따라 InAs QD의 크기가 점차 증가하므로 QD 크기의 변화가 single layer인 QD1 시료보다 훨씬 크다. QD1의 PL 소멸은 파장이 증가함에 따라 점차 느려지다가 PL 피크 근처에서 가장 느린 소멸 곡선을 보이고, 파장이 더 증가하였을 때 PL 소멸은 점차 빠르게 소멸하였다. 그러나 QD2의 PL 소멸곡선은 파장이 증가함에 따라 점차 빠르게 소멸하였다. 이것은 QD2는 양자점 크기의 변화가 매우 크기 때문에 (lateral size=18~29 nm, height=2.8~5.9 nm) 방출파장이 증가함에 따라 양자점 사이의 파동함수의 겹침이 증가하여 캐리어의 이완이 증가하기 때문으로 설명된다. 온도에 따른 TRPL 결과는 두 시료 모두 10 K에서 150 K 까지는 소멸시간이 증가하였고, 150 K 이후부터는 소멸시간이 감소하였다. 온도가 증가함에 따라 소멸시간이 증가하는 것은 양자점에서 장벽과 WL (wetting layer)로 운반자(carrier)의 이동, 양자점들 사이에 열에 의해 유도된 운반자의 재분배 등으로 인한 발광 재결합으로 설명할 수 있다. 150 K 이상에서 소멸시간이 감소하는 것은 열적효과에 의한 비발광 재결합 과정에 의한 운반자의 소멸이 증가하기 때문이다. 온도에 따른 TRPL 결과는 두 시료 모두 150 K까지는 발광재결합이 우세하고, 150 K 이상에서 비발광재겹합이 우세하게 나타났다.

  • PDF

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF