• Title/Summary/Keyword: 온도균일도

Search Result 1,193, Processing Time 0.029 seconds

Effects of Pre-sowing Treatments of Tobacco Seed on Germination and Seedling Uniformity (담배종자의 파종 전처리가 발아 및 묘의 균일성에 미치는 영향)

  • 민태기
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.6
    • /
    • pp.507-512
    • /
    • 1993
  • Pre-sowing treatments of tobacco seeds (cv. NC82) were evaluated as a means of improving the speed of emergence, early seedling growth and uniformity of the seedlings. Seeds were treated through the use of polyethylene glycol 6000(PEG), solid matrix priming(SMP), chilling and dark-preincubati(DPI). Under the laboratory condition of 15$^{\circ}C$, all the treated seeds germinated more rapid and the time to 50% germination(T50) reduced than control. Among the treatments, SMP was the best to reduce the T50 for germination. All the treatments did not affect the final germination percentage, while the chilling showed of little benefit for germination and T50. Under the greenhouse condition, seedling from SMP emerged earlier and more uniformity and also greater mean fresh and dry weight showed than other treatments. The advantage of T50 from SMP was affected more in temperature than in water content of Agro-Lig during the treatment.

  • PDF

Evolution of Hydrothermal Fluids at Daehwa Mo-W Deposit (대화 Mo-W 열수 맥상 광상의 유체 진화 특성)

  • Jo, Jin Hee;Choi, Sang Hoon
    • Economic and Environmental Geology
    • /
    • v.46 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • The Daehwa Mo-W deposit is located within the Gyeonggi massif. Quartz and calcite vein mineralization occurred in the Precambrian gneiss and Jurassic granites. Three main types (Type I: liquid-rich $H_2O$ type, Type II: vapor-rich $H_2O$ type, Type III: $CO_2-H_2O$ type) of fluid inclusions were observed and are classified herein based on their phase relations at room temperature. Within ore shoots, type III fluid inclusions have been classified into four subtypes (type IIIa, IIIb, IIIc and IIId) based on their volume percent of aqueous and carbonaceous ($CO_2$) phase at room temperatures combined with their total homogenization behavior and homogenization behavior of $CO_2$ phase. Homogenization temperatures of primary type I fluid inclusions in the quartz range from $374^{\circ}C$ to $161^{\circ}C$ with salinities between 13.6 and 0.5 equiv. wt.% NaCl. Homogenization temperatures of primary type III fluid inclusions in quartz of main generation, are in the range of $303^{\circ}C$ to $251^{\circ}C$. Clathrate melting temperatures of the type III fluid inclusions were 7.3 to $9.5^{\circ}C$, corresponding to salinities of 5.2 to 1.0 equiv. wt. % NaCl. Melting and homogenization temperatures of $CO_2$ phase of type III fluid inclusions were -57.4 to $-56.6^{\circ}C$ and 29.0 to $30.8^{\circ}C$, respectively. Fluid inclusion data indicate a complex geochemical evolution of hydrothermal fluids. The Daehwa early hydrothermal system is characterized by $H_2O-CO_2$-NaCl fluid at about $400^{\circ}C$. The main mineralization occurred by $CO_2$ immiscibility at temperatures of about 300 to $250^{\circ}C$. At the late base-metal mineralization aqueous fluid formed by mixing with cooler and less saline meteoric groundwater.

A study on the design of air conditioning system in the mushroom cultivation greenhouse (버섯재배사의 공조시스템 설계에 대한 연구)

  • Ryu, Kyung-Jin;Son, Jae-Hwan;Han, Chang-Woo;Nah, Kyu-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.743-750
    • /
    • 2017
  • It is important to ensure a uniform temperature distribution in greenhouses for the mushroom cultivation. The air temperature of the mushroom cultivation greenhouse is made uniform by supplying a constant air temperature with the underground air. The mushroom cultivation array in a greenhouse in seven columns and four rows can make smooth air flows between the rows and prevent air differences between the top and bottom. The buoyancy effect in the entering air of 0.5m/s based on following density difference depending on initial internal temperature needs to be considered. The locations of the Fan Coil Unit (FCU) and fan were defined through flow analysis in a greenhouse to distribute the optimal uniform temperature. In this study, the air conditioning system of a greenhouse with a sandwich heat insulting panel shape which is composed of a FCU and fan was designed by flow analysis. A relatively uniform temperature distribution can be formed because the circulation path of air becomes longer in the different locations of the FCU (inlet) and fan (outlet) through the internal temperature and flow analysis. The cultivation and quality uniformity of the mushrooms could be promoted through these environmental improvements.

Effects of pH and temperature on deposition behavior of black trivalent chromium deposition (흑색 3가크롬도금의 전착거동에 미치는 pH 와 온도의 영향)

  • Kim, Ji-Hyeon;Lee, Gyu-Hwan;U, Chang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.141-141
    • /
    • 2009
  • 흑색 3가크롬용액을 최적의 전착조건을 찾기 위해서 pH와 온도의 변화에 따란 Hull-cell test, 두께측정, 분극실험을 실시하였다. 온도가 올라갈수록, pH가 낮을수록 도금층의 두께가 두꺼워졌으나, 온도 $40^{\circ}C$, pH 3.4-3.8일때 균일한 도금층을 얻을 수 있었다.

  • PDF

Development of Ceramic Pepper Dryer (세라믹 고추 건조기 개발)

  • Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.178-180
    • /
    • 2008
  • 세라믹 건조기를 개발하기 위하여 탄화규소가 주원료로한 세라믹 발열판을 제작하여 건조기 내부에 설치하여 실험하였다. 발열판 장착위치에 따른 실험결과 위치는 큰 변수가 되지 않았고, 발열판 자체 온도 분포를 측정한 결과 시간이 흐름에 따라 온도 분포는 약간의 차이가 있기는 하지만 대체적으로 균일한 분포를 나타내었다.

  • PDF

Analysis of A Straight Fin with Temperature-Dependent Thermal Conductivity (균일한 단면을 가진 직선 핀에 대하여)

  • Kim Kwan Ho
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.2
    • /
    • pp.87-90
    • /
    • 1977
  • 핀(fin) 재료의 열전도계수는 온도에 따라 직선적으로 변한다고 가정하여 일차적, 정상상태의 해석을 하였다. 정밀해는 타원적분의 함수로 표시된다. 핀(fin) 효율은 핀끝의 온도의 함수로 주어졌다. 계산을 용이하게 하기 위하여 perturbation해도 구하였다.

  • PDF

Effects of Light Quality, Temperature or Vermiculite Depth on Germination for the Veronica L. (광질, 온도 및 복토 깊이가 꼬리풀 (Veronica L.) 종자의 발아에 미치는 영향)

  • Cheon Young Song;Ja Young Moon;Jung Won Sung;Byeong Seon Park;Jae Ik Nam;Jeong Min Kim
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.1
    • /
    • pp.36-47
    • /
    • 2023
  • This study was conducted to develop a mass production for a commercial use by germination of 4 kinds of Veronica glabrifolia Kitag., V. pusanensis Y.N.Lee, V. glabrifolia Kitag. × V. Spicata 'Alba' and V. spicata 'Ulster Blue Dwarf × V. longifolia. Veronica L. Effects of dipping time to a disinfecting fluid, light quality, temperature or vermiculite depth on the germination of Veronica L. were examined. Germination percentage in a disinfecting fluid for 120 minutes dipping was the 75.1% for V. pusanensis Y.N.Lee, and was some higher in 60 minutes dipping for all the species, but there was no significant difference according to the dipping time. The germination of the light quality was the best in complex light (red light + blue light) as the germination 92.8%, uniformity 2.3 in Veronica glabrifolia Kitag., or the germination 85.9%, uniformity 3.5 in V. pusanensis Y.N.Lee. And the germination percentage of red light was ranged from 79.1% to 95,5%, the blue light was 83.1% to 100% in the all species. However the germination in the dark condition significantly lowered as a 40.0% to 56.3% or uniformity from 5.2 to 6.5. Like this, the germination of blue light was better compare to the red light. The germination rate according to temperature was higher at 25℃ day/20℃ night ranged from 92.1% to 100%, or at 20℃ day/15℃ night as a 85.5% to 98.9% in the all species, compare to constant temperature 25℃ as a 80.9% in V. pusanensis Y.N.Lee. The germination rate of vermiculite depth was higher in 1 to 2mm ranged from 83.4% to 100%, however when the vermiculite was covered with 4mm, the germination rate significantly decreased from 45.2% to 72.1% and the hypocotyl length became longer above 3cm than that of others.

Performance Improvement of Hot-Air Dryer Through Optimum Round-Hole Plate (최적의 타공판을 통한 열풍건조로 성능향상 연구)

  • Seo, Eung Soo;Kim, Yongsik;Hwang, Joong Kook;Chai, Young Suck;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.947-954
    • /
    • 2015
  • The homogeneous coating of a flexible film that is applied to dye-sensitized solar cells is related to the performance and durability of the product. The applied coating is obtained from the uniform temperature distribution and the mass flow rate in the nozzle of the hot air dryer. In this study, we determine the uniform temperature distribution and mass flow rate of each nozzle by performing numerical simulations to understand how various factors affect the performance of the hot air dryer. The numerical model is composed of the momentum equation for flow motion and the energy equation for temperature. In addition, we compare the numerical results to the experimental results to validate the model. Based on the results, the round-hole plate inside the hot air dryer significantly affects the uniform temperature and the mass flow rate.

Responsivity and Noise Evaluation of Infrared Thermal Imaging Camera (적외선열화상카메라의 응답 및 노이즈 특성 평가)

  • Kim, Dong-Ik;Kim, Ghiseok;Kim, Geon-Hee;Chang, Ki Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.342-348
    • /
    • 2013
  • In this paper, the evaluation method for the responsivity and noise characteristics of an infrared thermal imaging camera was presented. Signal transfer function and noise equivalent temperature difference of the infrared thermal imaging camera were obtained by using a differential mode blackbody that is able to control the temperature difference ${\Delta}$T between an infrared target and its background. And we verified the suitability of our evaluation method through comparison between the found noise equivalent temperature difference and the specification of the camera. In addition, the difference of 0.01 K of the two noise equivalent temperature differences calculated from with and without nonuniformity correction suggests that the nonuniformity correction is essential process for the evaluation of the infrared thermal imaging camera.

Thermal Distribution in a Phantom Using 8MHz RF Capacitive Type Hyperthermia (8 MHz 고주파 유전형 가열장치로 가열한 모형에서의 열분포)

  • Lee Jong Young;Park Kyung Ran;Kim Kye Jun;Sung Ki Joon
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.171-176
    • /
    • 1991
  • To evaluate the temperature distribution according to the size of the electorde and the thickness of the phantom using 8MHz radiofrequency capacitive heating device, various sized electrodes and phantoms were used in combination. The radii of the electrodes are 10, 15, 20, 25, and 30 cm and the thickness of cylindrical phantoms with diameter 30 cm were 10, 15, 20, 25, 30, and 35 cm. When the thickness of the phantom was 25 cm or 30 cm, homogenous heating was achieved by using the electrode which diameter was equal to or greater than the thickness of the phantom. When the thickness of the phantom was 20 cm or less. homogenous heating was not achieved by using the electrode which diameter was equal to the thickness of the phantom, but achieved by the larger diameter of the electorode. When the sizes of paired electrodes were not equal, the smaller electrode side was preferentially heated.

  • PDF