• Title/Summary/Keyword: 온도구배

Search Result 369, Processing Time 0.026 seconds

Variation of time-dependent convection beat transfer coefficients in beat transfer analysis at various initial beating rates of tunnel fire scenarios (요소제거모델을 활용한 열전달해석에서 터널 화재이력곡선의 초기가열구배에 따른 대류열전달계수의 변화)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Jun-Hwan;Ahn, Sung-Yol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.223-237
    • /
    • 2010
  • The initial heating rate is well known as one of the most influencing factors on the occurrence of spalling and the loss of strength in concrete after fire initiation. In this study, a series of fire tests were carried out at different initial heating rates to find out its effects on the deterioration of tunnel structural members. Heat transfer analyses combined with an element elimination model were also carried out to verify its applicability in the same conditions as the fire tests. Moreover, the convection heat transfer coefficients compatible with fire test results were derived from parametric studies. In this course, their time-dependent variations were also analyzed at different initial heating rates. Finally, a numerical formula to estimate the heat transfer coefficients at the various initial heating rates was proposed by the interpolation of the results of numerical analyses.

An Experimental Study on the Temperature Difference between the Top and Bottom Flange in Steel Girder without Concrete Slab (콘크리트 슬래브가 없는 강재주형에서 상하연 온도차에 대한 실측연구)

  • Shin, Dong-Wook;Kim, Kyoung-Nam;Jung, Kyoung-Sup;Lee, Seong-Haeng
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.99-106
    • /
    • 2014
  • In order to study the reasonable design thermal loads, the steel box girder bridge specimen which have no concrete slab was manufactured with the real size dimension. The temperature data were measured for 5 month at the 18 thermo gauges which were attached according to height. The temperature differences between the top and bottom flange in steel box girder specimen were calculated and the temperature gradient models were proposed by the probabilistic method. This proposed model showed a correlation of approximately 97% when compared with the similar model of Euro Code. Thus, the temperature gradient models which were suggested in this study may be used as the basis data in calculating the design load temperature.

Study of Different Radial Temperature Gradient Effect on Taylor-Couette Flow Instability (온도구배가 Taylor-Couette유동의 불안정성에 주는 영향에 관한 연구)

  • Cha, Jae-Eun;Liu, Dong;Tu, Xin Cheng;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.35-40
    • /
    • 2010
  • We have investigated different radial temperature gradient effect on the stability of Taylor-Couette flow. The radius ratio and aspect ratio of the model was 0.825 and 48, respectively. Two heating exchangers were used for generating different temperature gradient along the radial direction. The change of flow regime in the Taylor-Couette flow was studied by increasing the Reynolds number. The results showed that: as Gr is increased in helical vortex flow regime, the vortices with the same direction of convection flow increased in size, and the vortex moving velocity also increased. It is also shown that the presence of temperature gradient obviously increased the flow instability when the Richardson number is larger than 0.0045.

Experimental Study of the Axial Slit Wall and Radial Temperature Gradient Effect on Taylor-Couette Flow (Taylor-Couette 유동에서 축방향 홈과 반경방향 온도구배의 영향에 대한 실험적 연구)

  • Lee, Sang-Hyuk;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.2
    • /
    • pp.33-38
    • /
    • 2008
  • The effect of the radial temperature gradient and the presence of slits in the wall of outer of two cylinders involved in creating a Taylor-Couette flow was investigated by measuring the velocity field inside the gap. The slits were azimuthally located along the inner wall of the outer cylinder and the number of slits used in this study was 18. The radius ratio and aspect ratio of the models were 0.825 and 48, respectively. The heating film wrapped around the inner cylinder was used for generating the constant heat flux and we ensured the constant temperature condition at the outer space of the outer cylinder. The velocity fields were measured by using the PIV(particle image velocimetry) method. The refractive index matching method was applied to remove image distortion. The results were compared with plain wall configuration of Taylor-Couette flow. From the results, the presence of slits in the wall of outer cylinder and temperature gradient increased the flow instability.

An experimental study on the heat transfer and turbulent flow of round jet impinging the plate with temperature gradient (온도구배를 갖는 평판에 대한 원형 충돌제트의 열전달 및 난류유동에 관한 실험적 연구)

  • 한충호;이계복;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.855-860
    • /
    • 1999
  • An experimental study of jet impingement on the surface with linear temperature gradient is conducted with the presentation of the turbulent characteristics and the heat transfer rates measured when this jet impinges normally to a flat plate. The jet Reynolds number ranges from 30,000 to 90,000, the temperature gradient of the plate is 2~$4.2^{\circ}C$/cm and the dimensionless nozzle to plate distance(H/D) is from 6 to 10. The results show that the peak of heat transfer rate occurs at the stagnation point, and the heat transfer rate decreases as the radial distance from the stagnation point increases. A remarkable feature of the heat transfer rate is the existence of the second peak. This is due to the turbulent development of the wall jet. Maximum heat transfer rate occurs when the axial distance from the nozzle to nozzle diameter(H/D) is 8. The heat transfer rate can be correlated as a power function of Prandtl number, Reynolds number and the dimensionless nozzle to plate distance(H/D). It has been found that the heat transfer rate increases with increasing turbulent intensity.

  • PDF

A Study on the Temperature Analysis of Casting Mould by Boundary Element Method (경계요소법을 이용한 주철제 주형의 온도해석에 관한 연구)

  • 민수홍;조의일;김옥삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.485-496
    • /
    • 1992
  • 본 연구에서는 제철, 제강공정에서 많이 사용하고 있는 C22FR1.4형의 주형을 상사적으로 축소시킨 주철제(GC25) 주형에 순알루미늄(순도99%)의 주물을 용입하여 응고 및 냉각 과정의 주물 및 주철제 주형에 미치는 열의 영향에 관하여 2차원 비정상 열전도 문제를 경계요소법으로 해석하고 실험을 통하여 검증하였다.

Growth response to Light, Moisture and Nutrients for the Conservation Measures of Bupleurum latissimum(Apiaceae, endangered species) under Future Climate Environment(Elevated CO2 Concentration and Temperature) (기후변화환경 하에서 멸종위기식물 섬시호(산형과)의 보전방안 마련을 위한 광, 수분, 영양소에 대한 반응 연구)

  • Ahn, Kyeong-Ho;You, Young-Han;Cho, Kyu-Tae
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.5
    • /
    • pp.803-809
    • /
    • 2016
  • In order to elucidate the ecological responses of B. latissimum under global warming situation and prepare the conservation measures, we cultivated the plant within control(ambient $CO_2+$ambient temperature) and treatment(elevated $CO_2+$elevated temperature) from 2010 to 2011. Rising $CO_2$ concentration was treated with 2 times and temperature increased with $2.0^{\circ}C$ above than control. As a result, Growth response has received more the effect of $CO_2+$Temperature rising than light, moisture, nutrients, and it was grow well in $CO_2+$temperature rise sphere when many nutrients, and it was grow well in $CO_2+$temperature rise sphere when many nutrients. No. of leaves were many number in the treated group compared to the control at a low light gradient and high nutrient gradient, leaf width was narrow in the treatment compared to the control in the middle gradient of light and nutrients. Shoot length, petiole length, lamina length was no difference between control and $CO_2+$temperature rise sphere. Based on the results of this study, in order to preserve the B. latissimum in future climate, we should be supply of nutrients(containing ${NH_4}^+$, $NO_3$, $P_2O_5$, $K_2O$, etc.) in the habitat of the B. latissimum, and must ensure that the habitat of B. latissimum is not destroyed. Also, We should be find similar area with habitat of the B. latissimum, restoring, expanding.

The Genes Expression Patterns Induced by High Temperature in Licorice (Glycyrrhiza uralensis F.) (온도상승에 따른 감초(Glycyrrhiza uralensis Fisch.)의 유전자 발현 양상)

  • Hyeju Seong;Woosuk Jung
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.12a
    • /
    • pp.56-56
    • /
    • 2020
  • 감초는 다년생 콩과(Leguminocae) 식물로 국내에서 시중가격이 높은 만주감초가 일부 재배되고 있다. 우리나라에서 감초 재배법이 불완전한 상황에서 한반도의 기후변화에 의한 온도 상승은 약용작물의 생산 및 품질에 많은 영향을 미칠 것으로 예상되므로 본 연구에서는 재배환경 중 온도 조건만 조절할 수 있는 온도구배터널(temperature gradient tunnel system)을 이용하여 4개의 T1(외기온도+0.5~1.3℃), T2(+1.3~2.2℃), T3(+2.2~3.2℃), T4(+3.2~4.0℃) 처리로 온도구배 하여 4년생 만주감초(Glycyrrhiza uralensis F.)를 재배하였다. 지하부가 오래된 모주와 신초1의 경우 저온(T1)과 중간구간(T2, T3)에서 초장과 총화수가 우세하였고, 번식이 가장 늦은 신초2의 경우 중간구간(T2, T3)에서의 생육 및 개화반응이 뚜렷했다. 각 온도처리구마다 3개의 감초 개체를 선발하여 모주의 정단으로부터 5개의 성엽을 채취하였다. Reverse transcription quantitative PCR (RT-qPCR)은 AccuPower® GreenStarTM RT-qPCR Master Mix (Bioneer, Korea)를 이용하여 진행되었다. Primer 디자인은 NCBI Primer-blast 프로그램을 사용해 제작하였고 ABI StepOne real time system (Applied Biosystem)의 melting curve analysis에서 one-peak test를 통해 gene specific primer임을 확인하였다. 각 온도처리구의 감초 잎에서 RNA를 추출하였고, RT-qPCR을 통해 감초의 유전자 발현양상을 비교, 분석하였다. Phytochrome interacting factor 4 (PIF4)는 식물 호르몬을 유발하는 전사조절을 조정함으로써 고온 신호전달에 핵심적인 역할을 수행한다. 활성화된 Phytochrome B(PhyB)는 PIF4의 활성을 억제한다고 알려졌다. Eukaryotic initiation factors(eIFs)는 mRNA 번역 개시인자로 유전자 발현과 특정 단백질 생산을 조절하는 역할을 한다. 본 결과는 온도조건에서 반응하는 생리적 변화를 전사체 수준에서 조사 분석하여 생리해석의 기초자료로 활용, 국내 감초 재배를 위한 환경조건 구명 및 적지 선정 기초자료로서 활용을 기대한다.

  • PDF

The Growth of $CaF_2$ Single Crystal by Tammann Method (탐만법에 의한 $CaF_2$ 단결정 육성)

  • 장영남;채수천;문희수
    • Korean Journal of Crystallography
    • /
    • v.10 no.1
    • /
    • pp.20-27
    • /
    • 1999
  • CaF2 단결정을 흑연도가니를 사용하여 He 분위기 하에서 탄만법으로 성장시켰다. 수화방지를 위해 PbF2를 출발물질에 도포하였다. 열구배에 따른 계면의 움직임인 성장속도는 배플판에 의해 성공적으로 조절되었다. 결정성장의 최적조건은 온도구배가 37℃/cm, 냉각속도가 10℃/hr 및 2.5tw% PbF2를 사용한 경우로, 성장속도는 약 3.2 mm/hr이었으며, 위로 볼록한 고액계면을 갖는 단결정이 성장되었다. IR분석 결과, 1500∼4000 cm-1(6.7∼2.5 ㎛)영역에서 약 96%의 투과도를 보였다. 결함밀도를 측정하기 위해, 성장축에 수직 및 수평으로 절단한 면을 농축 H2SO4에서 약 30분간 에칭하여 간섭현미경으로 관찰한 결과, 각각 3.4×104/cm2였다. 이러한 결과는 수화에 따른 성장된 단결정의 투명도의 경향과 일치하였다. 결정에 대한 XRD분석 결과 우선성장 방향은 <311>이었다.

  • PDF

A Study for Characteristics of Stack Plume Dispersion under Various (다양한 대기풍속 및 대기온도 구배 조건에서의 공장 배출 가스의 확산 특성에 관한 연구)

  • Park, Il-Seouk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.773-780
    • /
    • 2010
  • The dispersion of plume which is emitted from a chimney is governed by a lot of factors: wind, local terrain, turbulence intensity of atmosphere, and temperature, etc. In this study, we numerically investigate the plume dispersions for various altitudinal temperature gradients and wind speeds. The normal atmosphere has the temperature decrease of $0.6^{\circ}C/100m$, however, actually the real atmosphere has the various altitudinal temperature profiles according to the meteorological factors. A previous study focused on this atmospheric temperature gradient which induces a large scale vertical flow motion in the atmosphere thus makes a peculiar plume dispersion characteristics. In this paper, the effects of the atmospheric temperature gradient as well as the wind speed are investigated concurrently. The results for the developing processes in the atmosphere and the affluent's concentrations at the ambient and ground level are compared under the various altitudinal temperature gradients and wind speeds.