• Title/Summary/Keyword: 온도계수(temperature coefficient)

Search Result 878, Processing Time 0.03 seconds

Investigation of the Relationship Between Wall Thermal Conductivity and Inner Room Temperature in Compartment Fires (구획화재에서 벽면의 열전도 계수와 내부 온도의 상관관계 분석)

  • You, Woo Jun;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.17-23
    • /
    • 2018
  • In this study, the relations of the wall thermal conductivity and surface temperature in a compartment fire are investigated using Buckingham Pi theorem. The dimensionless parameters of the previous study are analyzed in order to correlate the dimensionless groups of the heat release rate, the thermal conductivity, the volume of compartment and the convective heat transfer coefficient. In addition the reduced scale of compartment, which has 1/6 size of ISO 9705 Room Corner Tester, is manufactured and the oxygen concentration and the maximum temperature in the space are measured for the gasoline pool fire ($10cm{\times}10cm$, $15cm{\times}15cm$ and $20cm{\times}20cm$). Finally, the criterion of the wall temperature increase are suggested in accordance with the thermal conductivity and the convective heat transfer coefficient. In addition, the dimensionless empirical equation using Buckingham Pi theorem considering the heat release rate are presented suggested. The results of this study will be useful especially for the fire phenomenon investigation of the wall thermal conductivity coefficient and shape in the compartment space.

Modeling for Temperature Dependent Effective ionization Coefficient of Si $p^+n$ Junction Diodes (Si $p^+n$ 접합 다이오드의 온도를 고려한 유효 이온화 계수 모델링)

  • Chung Yong Sung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.9-14
    • /
    • 2004
  • In this paper, temperature dependence of effective ionization coefficient in Si is formulated as a single polynomial function of temperature, which allows analytical expressions for breakdown voltage of Si $p^+n$ junction as a function of temperature. The analytical breakdown voltages agree well with the simulation as well as the experimental ones reported within $3\%$ in error for the doping concentrations in the range of $10^{14}cm^{-3}{\~} 10^{17}cm^{-3}$ at 100K, 300K and 500K.

Estimation of Heat Transfer Coefficient at the Upper Layer of Cryogenic Propellant (극저온 추진제 상층부에서의 열전달계수 예측)

  • Kwon, Oh-Sung;Kim, Byung-Hun;Kil, Gyoung-Sub;Ko, Young-Sung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.82-89
    • /
    • 2012
  • The temperature of cryogenic propellant in the propellant tank increases during flight due to heat input from surroundings. The propellant which temperature rises up over the required condition of turbo-pump remains as unusable propellant at the end of flight. In this paper the estimation method of the heat transfer coefficient at the upper layer of cryogenic propellant was presented. The heat transfer mode at the propellant upper layer was considered as conduction. Temperature distributions near propellant surface obtained from heat transfer coefficient were compared with test data to show the possibility of this method.

Estimation of Heat Transfer Coefficient at the Upper Layer of Cryogenic Propellant (극저온 추진제 상층부에서의 열전달계수 예측)

  • Kwon, Oh-Sung;Kim, Byung-Hun;Kil, Gyoung-Sub;Ko, Young-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.709-716
    • /
    • 2011
  • The temperature of cryogenic propellant in the propellant tank increases during flight due to heat input from surroundings. The propellant which temperature rises up over the required condition of turbo-pump remains as unusable propellant at the end of flight. In this paper the estimation method of the heat transfer coefficient at the upper layer of cryogenic propellant was presented. The heat transfer mode at the propellant upper layer was considered as conduction. Temperature distributions near propellant surface obtained from heat transfer coefficient were compared with test data to show the possibility of this method.

  • PDF

Relationship Between Coefficient of Thermal Expansion and Glass Transition Temperature in Phosphate Glasses (인산염유리의 선팽창계수와 유리전이온도의 관계)

  • 전재삼;차명룡;정병해;김형순
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1127-1131
    • /
    • 2003
  • Phosphate glasses known for low melting temperature glasses in electrical parts has been recently used in wide area with modification of thermal properties using alkali oxides. It is our purpose to find a correlation between thermal expansion coefficient, glass transition temperature and melting temperature through investigating thermal properties in P$_2$O$\sub$5/-SnO-ZnO-SiO$_2$/B$_2$O$_3$. As a result, the product of thermal expansion coefficient and the glass transition temperature in the glasses is found to be a constant value would be a unique value for knowing one of thermal properties.

Experimental Study on the Determination of Heat Transfer Coefficient for the KURT (KURT 내 열전달계수 결정에 관한 실험적 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.507-516
    • /
    • 2009
  • In cases of high-level radioactive waste repositories, heat load is apparent by radioactive waste decay. The safety of a waste repository would be influenced by changing circumstances caused by heat transfer through rock. Thus, a ventilation system is necessary to secure the waste repository. The first priority for building an appropriate ventilation system is completing a computer simulation research with thermal rock properties and a heat transfer coefficient. In this study, the heat transfer coefficient in KURT was calculated using the measurement of inner circumstance factors that include dry bulb and wet bulb temperature, rock surface temperature, and barometric pressure. The heater that is 2 m in length and 5 kw in capacity heats the inside of rock in the research module by $90^{\circ}C$. As a result of determining the heat transfer coefficient in the heating section, the changes of heat transfer coefficient were found to be a maximum of 7.9%. The average heat transfer coefficient is approximately 4.533 w/$m^2{\cdot}K$.

A Design of Output Voltage Compensation Circuits for Bipolar Integrated Pressure Sensor (바이폴라 공정을 이용한 압력센서용 출력전압 보상회로의 설계)

  • Lee, Bo-Na;Kim, Kun-Nyun;Park, Hyo-Derk
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.300-305
    • /
    • 1998
  • In this paper, integrated pressure sensor with calibration of offset voltage and full scale output and temperature compensation of offset voltage and full scale output were designed. The signal conditioning circuitry are designed that calibrate the offset voltage and full scale output to desired values and minimize the temperature drift of offset voltage and full scale output. Designed circuits are simulated using SPICE in a bipolar technology. The ion implanted resistor of different temperature coefficient were used to trimming the desired values. As a results, offset voltage was calibrated to 0.133V and the temperature drift of offset voltage was reduced to $42\;ppm/^{\circ}C$. Also, the full scale output was calibrated to 4.65V and the temperature coefficient of full scale output was reduced to $40ppm/^{\circ}C$ after temperature compensation.

  • PDF

Determination of Convection Heat Transfer Coefficient Considering Curing Condition, Ambient Temperature and Boiling Effect (양생조건·외기온도·비등효과를 고려한 콘크리트 외기대류계수의 결정)

  • Choi Myoung-Sung;Kim Yun-Yong;Woo Sang-Kyun;Kim Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.551-558
    • /
    • 2005
  • The setting and hardening of concrete is accompanied with nonlinear temperature distribution caused by development of hydration heat of cement. Especially at early ages, this nonlinear distribution has a large influence on the crack evolution. As a result, in order to predict the exact temperature history in concrete structures it is required to examine thermal properties of concrete. In this study, the convection heat transfer coefficient which presents thermal transfer between surface of concrete and air, was experimentally investigated with variables such as velocity of wind, curing condition and ambient temperature. At initial stage, the convection heat transfer coefficient is overestimated by the evaporation quantity. So it is essential to modify the thermal equilibrium considered with the boiling effect. From experimental results, the convection heat transfer coefficient was calculated using equations of thermal equilibrium. Finally, the prediction model for equivalent convection heat transfer coefficient including effects of velocity of wind, curing condition, ambient temperature and boiling effects was theoretically proposed. The convection heat transfer coefficient in the proposed model increases with velocity of wind, and its dependance on wind velocity is varied with curing condition. This tendency is due to a combined heat transfer system of conduction through form and convection to air. From comparison with experimental results, the convection heat transfer coefficient by this model was well agreed with those by experimental results.

Effect of Temperature Variations on Heat Transfer Coefficient in Crossflow over a Circular Cylinder (온도변화가 실린더 주위 열전달계수에 미치는 영향에 관한 실험적 연구)

  • Kauh, S.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.137-145
    • /
    • 1992
  • coefficient precisely, experiments were carried out in three categories which contain the regime of (1) constant wire temperature (2) constant fluid temperature (3) constant temperature difference between wire and fluid. Measurements were made with electrically heated circular tungsten wire placed normal to air stream at the exit of jet. Heat transfer coefficient was increased with wire temperature increasing and decreased by fluid temperaure increasing and was not changed with varying both temperature if their difference were kept constant.

  • PDF

Measurement of Thermal Expansion Coefficient of Rock using Strain Gauge (스트레인 게이지를 이용한 암석의 열팽창계수 측정)

  • Park, Chan;Kim, Hyung-Mok;Synn, Joong-Ho;Park, Yeon-Jun;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.17 no.6
    • /
    • pp.475-483
    • /
    • 2007
  • With increasing demand for LNG as energy resources and need for $CO_2$ sequestration as greenhouse gas, more storage facilities are required in Korea. Due to the recent acute safety concerns and land shortage, storage facilities tend to be located underground. In design and construction of underground storage for low and high temperature materials, besides their mechanical characteristics, the thermal characteristics of rock under temperature variation should be understood. In this study, laboratory experiments for the measurement of the thermal expansion coefficient of rock were performed using strain gauge in consideration of the particle size of mineral and experiment temperature range. Experiment results show that thermal expansion coefficient decreased as the temperature decreases. In addition, linear thermal expansion coefficient was developed for typical Korean rocks such as granite. The results of this study can be utilized for the evaluation of thermal propagation in rock mass and the thermo-mechanical stability of underground facilities.