• Title/Summary/Keyword: 옥외

Search Result 723, Processing Time 0.029 seconds

Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings (가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가)

  • Cho, H.G.;Kim, I.S.;Ahn, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

Field Test Facilities for Composite Long Rod Insulator (고분자(高分子) 장간애자용(長幹碍子用) 옥외(屋外)시험장(試驗場) 구축(構築))

  • Hahn, Key-Man;Kim, Dong-Wook;Kwon, Hyuk-Sam;Yoo, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1499-1501
    • /
    • 1994
  • This paper studies on the outdoor field test facilities which are established for weather-resist and mechanical-resist property teat of composite insulator. We have established measuring and data acquisition system for various test conditions -leakage current, temperature, humidity, wind direction, wind velocity and rainfall. The merry-go-round test and salt fog test have been studied in order to evaluate non tracking property of rubber material. Especially we have checked the relationship between hydrophobicity and outdoor exposure degree by contact angle measurement.

  • PDF

Assesment of Chemical Resistance of Geomembranes by UV Exposure (지오멤브레인의 옥외노출시험에 의한 화학저항성 평가)

  • Jeon, Han-Yong;Jung, Gu;Choi, Jun-Dong;Park, Jin-Hyuk;Cho, Sung-Ho
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.424-427
    • /
    • 2001
  • 최근에 지오멤브레인, 지오텍스타일 등의 토목합성재료들이 각종 토목공사에 다양한 용도로 사용되고 있고, 그 사용량이 증가함에 따라 이들 재료들의 각종 성능에 대한 평가가 요구되고 있다. 특히 다양한 원료로 제조된 섬유 고분자 재료들을 적용시킨 현장 시스템의 경우 주변환경에 대한 장기 안정성이 요구되며, 주변환경에 대한 안정성은 제조에 이용되는 고분자의 화학조성에 기인한다. (중략)

  • PDF

Development of Outdoor 50W-LED Module using Heat-pipe and Stack-fin (히트파이프 및 스택핀을 이용한 50W급 옥외용 LED 모듈개발)

  • Hong, Seok-Gi;Jeong, Hee-Suk;Ryeom, Jeong-duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.15-21
    • /
    • 2015
  • We proposed 50W-LED modules of using Heat-pipe and Stack-fin and produced LED modules was evaluated heat dissipation characteristics with comparison of the conventional die-casting type. It verified the application of products by applying it to 150W-LED road luminaires through simulation. The LED module was measures aimed design temperature of the Stack-fin and showed 26% upward heat dissipation effect than a conventional die-casting type. The luminous efficacy of 150W-LED road luminaires using this LED module reached over 112lm/W, and the simulation results showed average of horizontal luminance, overall luminance uniformity($U_O$) and lane luminance uniformity($U_I$) that is suitable for five-lane road with the KS standards.

Outdoor Testing and Degradation of EVA and POE Encapsulated Photovoltaic Modules (옥외 관측을 통한 EVA, POE PV모듈의 열화 연구)

  • Kim, Jeha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.847-852
    • /
    • 2016
  • Using both EVA and POE encapsulants, we fabricated polycrystalline Si PV modules and performed a set of reliability tests of PID, DH, TC, and Complex prior to outdoor installation. The power output with temperatures and insolation as well as I-V characteristics had been monitored under outdoor environments for 18 months. In the entire period, the total power of 3,576 kWh from POE PV modules was observed larger than 3,449 kWh from EVA PV modules by 3.5%. All the PV modules showed a 5.6~9.2% drop in the conversion efficiency. As for the solar power generation, the PV modules performed through PID, TC test revealed distinct difference in between EVA and POE for which the POE PV module produced more power by +11.4% and +6.6%, respectively, as measured in the 18th month. In addition, POE was proved to protect better the solar cells under PID influence.

A Study on Standards of Transformer Noise Level for Outdoor Substation (옥외 변전소 변압기의 소음레벨 기준에 대한 연구)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Kwak, Ju-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2213-2219
    • /
    • 2008
  • Customer complaints on noise from the power transformer have been increased because of their concerns on environment. In order to solve fundamental noise problem of the transformer, KEPCO and domestic transformer manufacturers are developing 55 dBA class low noise transformers. To check accordance of the noise abatement law, we study relation between transformer noise level and substation border noise level. We present 'noise level of the substation border' under operating conditions and transformer noise level change. We also present an appropriate noise level of the transformer that satisfy the noise abatement law for outdoor substations.

Development Process on IoT Platform for Faults Detection of Outdoor LED Lighting Installation (옥외 LED 조명설비의 고장검출 IoT 플랫폼 개발을 위한 프로세스)

  • Park, Kun-Young;Kwak, Dong-Kurl;Jung, Min-Sang;Park, Dong-Hun
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.273-274
    • /
    • 2018
  • Recently, many countries around the world are investing heavily in green industries based on green IT technology. The key industry in the green industry is LED. If we replace traditional lighting, we can save a lot of socioeconomic costs. Because it is energy efficient. However, the research and development on maintenance and management are still insignificant about LED lighting. Therefore, after the failure, the post-treatment is delayed and often occurs. In order to solve these problems, it is planned to detect the failure of the LED lighting and to establish a monitoring system that can monitor the situation in real time on the computer or mobile phone of the remote manager using the latest IoT network technology.

  • PDF

A Study on the variations of tracking resistance of outdoor Epoxy composites due to moisture absorption aging (흡습열화에 따른 옥외용 에폭시 복합체의 내트래킹성 변화에 관한 연구)

  • 김탁용;이덕진;가출현;김명호;박창옥;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.526-528
    • /
    • 1999
  • Epoxy resin has been used as matrix resin of advanced composites owing to ideally suitable properties and inherent physical and chemical properties for electrical and electronic insulation In this paper, in order to evaluate the performance of epoxy composites for out door insulation, variations of tracking resistance were investigated on the moisture absorption aging condition. Also, IPN methods were introduced in order to improve performance for out door use. As a result, it was confirmed that tracking resistance were degraded with boilling time. But, it was confirmed that specimen of IPN structure and KC-335 have the better tracking resistance properties than SIN structure by moisture absorption aging

  • PDF

The Diagnosis of Polymeric Insulation Materials for Outdoor in the Salt Fog (Salt fog 내에서 옥외용 고분자 절연물의 절연진단)

  • Moon, J.S.;Kim, J.H.;Lee, J.H.;Song, W.C.;Cho, H.G.;Yoo, Y.S.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1569-1571
    • /
    • 2000
  • The ageing process was checked by leakage current monitoring in Salt Fog Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the cumulative number of peak pulses. The acquired data were stored to the disc periodically. And, surface conductivity was measured to investigate loss of hydrophobicity. The results suggest that surface conductivity and leakage current are well corresponding to initial loss of hydrophobicity.

  • PDF

A Study on Solid Electron Display Effect availability Computer Display (컴퓨터 디스플레이를 이용한 입체 전광판 효과에 관한 연구)

  • Joo, Heon-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.01a
    • /
    • pp.233-234
    • /
    • 2016
  • 본 논문에서는 컴퓨터 디스플레이를 이용한 입체 전광판 효과에 대해서 나타낸다. 기존 전광판은 하드웨어로 LED를 이용하여 실내 및 옥외 설치되어 광고 및 홍보 효과를 나타내고 있다. 본 연구에서는 LED 전광판의 한계라고 할 수 있는 점광원으로서의 확산광의 효과가 미약한 것을 소프트웨어를 이용하여 해결하고, 설치비용 및 광고 내용 수정 등 설치 이후에 변경이 손쉽지 않는 것들을 소프트웨어를 이용하여 컴퓨터 디스플레이 함으로써 다양한 컬러, 다양한 텍스트, 다양한 동영상을 손쉽게 제작하고, 홍보 할 수 있다. 따라서 실내 LED 효과에 비해서 컴퓨터 디스플레이를 이용한 입체 전광판의 제작 및 내용 변경에 유지 관리가 매우 효과적임을 나타낸다.

  • PDF