• Title/Summary/Keyword: 오일유량계

Search Result 10, Processing Time 0.017 seconds

Development of Oil Flowmeter and Preliminary Evaluation for Establishing National Leak Standard (국가 리크표준기용 오일유량계 개발 및 예비 평가)

  • Hong, S.S.;Song, H.W.;Choi, I.M.;Park, Y.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.295-300
    • /
    • 2012
  • We preliminarily evaluated the performance of a flowmeter by the measurement of the pressure of a ionization gauge and the produced throughput (Q) using a vacuum system and pistons with the radius of 10 mm and 20 mm. The throughput range with the later piston was from $1{\times}10^{-1}Pa{\cdot}L/s$ to $1.2Pa{\cdot}L/s$ and that with the former piston was from $5.3{\times}10^{-1}Pa{\cdot}L/s$ to $1.05Pa{\cdot}L/s$. In these ranges, both pistons showed good repeatability and linearity. The developed oil flowmeter as the leak standard will be used in the calibration of standard leak.

Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement (다회선 초음파 유량계를 이용한 거래용 오일유량 측정)

  • Hwang, Shang-Yoon;Lee, Ho-June;Park, Ki-Hwan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF

Quality Properties of Conger Eel (Conger myriaster) Oils Extracted by Supercritical Carbon Dioxide and Conventional Methods (초임계 이산화탄소 및 유기용매를 이용하여 추출된 붕장어(Conger myriaster) 오일의 품질특성)

  • Park, Jin-Seok;Cho, Yeon-Jin;Jeong, Yu-Rin;Chun, Byung-Soo
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.275-282
    • /
    • 2019
  • In this study, the extraction of Conger myriaster oil by using supercritical carbon dioxide (SC-CO2) and organic solvent was investigated. The extraction conditions conducted for SC-CO2 varied for pressure (25, 30 MPa) and temperature (45, 55 ℃), while the SC-CO2 flow rate was kept constant during the experiment (27 g min-1) and hexane was used as a conventional organic solvent. The extraction yield indicated that the best extraction condition would be SC-CO2 at 55 ℃ and 30 MPa, resulting in the highest yield of 37.73 ± 0.14%. The oils were characterized for their fatty acid (FAs) composition using gas chromatography, while it was revealed that the major FAs were mystric acid, palmitoleic acid, oleic acid, electroosapentaenoic acid (EPA), and docosahexaenoic acid (DHA). The oxidation stability of the extracted C. myriaster oil was evaluated by measuring the acid value, peroxide value, and free fatty acid. The best oxidative stability was obtained from SC-CO2 extracted oil at 30 MPa and 55 ℃. There was a significant difference in the color properties of the SC-CO2 and hexane extracted oils, with the SC-CO2 extracted oil showing better chromaticity than the oil extracted using hexane. Extracting oils from C. myriaster with SC-CO2 could bring better economic benefits than using organic solvents. When supercritical carbon dioxide was used, there was no post-treatment process; thus, it was confirmed that this is a more environmentally friendly oil extraction method.

Fatty Acid Composition and Oxidative Properties of Anchovy Oil Extracted by Supercritical Carbon Dioxide (초임계 이산화탄소를 이용하여 추출된 멸치 오일의 지방산 조성 및 산화 특성)

  • Lee, Seung-Mi;Yun, Jun-Ho;Chun, Byung-Soo
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.266-272
    • /
    • 2011
  • Anchovy oil was extracted using supercritical carbon dioxide ($SCO_2$) and organic solvents. Extraction was carried out at temperature range from 40 to $60^{\circ}C$, and pressure range from 15 to 25 MPa. The flow rate of $CO_2$ (22 $gmin^{-1}$) was constant entire the extraction period of 1.5 h. The fatty acid composition of anchovy oil was analyzed by gas chromatography (GC). The main fatty acids of anchovy oil were myristic acid, palmitic acid, stearic acid, palmitoleic acid, EPA (eicosapentaenoic acid), and DHA (docosahexaenoic acid). In addition, the oil obtained by $SCO_2$ extraction contained a higher percentage of polyunsaturated fatty acids especially EPA and DHA comparing to the organic solvent extracted oil. The oxidative stability of oils extracted from Anchovy by $SCO_2$ extraction was compared to those extracted by organic solvents. Results showed that the storage periods of oils obtained by $SCO_2$ extraction were longer than those of organic solvents extraction.

Oil-Air Lubrication Characteristics of a High Speed Spindle System for Machine Tools(I) Effect of Oil Supply Rate, Rotational Spindle Speed and Spindle System Structure (공작기계용 고속주축계의 오일에어윤활특성에 관한 연구 (I) 공급유량, 주축회전수 및 주축계 구조의 영향)

  • 김석일;최대봉;박경호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.351-358
    • /
    • 1993
  • Recently a high speed spindle system for machine tools has attracted considerable attention to reduce the machining time, to improve the machining accuracy, to perform the machining of light metals and hard materials and to unite the cutting and grinding processes. In this study, a high speed spindle system is developed by applying the oil-air lubrication method, angular contact ball bearings, injection nozzles with dual orifices and so on. And a lubrication experiment for evaluating the performance of the spindle system is carried out. Especially, in order to establish the lubrication conditions related to the development of a high speed spindle system, the effects of oil supply rate, rotational spindle speed and so on are studied and discussed on the bearing temperature rise, bearing temperature distribution and frictional torque. And the effect of spindle system structure on the bearing temperature distribution is investigated.

The Effects of Oil on Refrigerant Flow through Capillary Tubes (냉동기유가 모세관내의 냉매유량에 미치는 영향)

  • 홍기수;황일남;민만기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.791-801
    • /
    • 2000
  • An experimental study was conducted to analyze the effects of oil on refrigerant flow through adiabatic capillary tubes, and to develop a model for mass flow rates of refrigerant/oil mixture at various capillary tubes and flow conditions. Mass flow rates and the profiles of the pressures and temperatures along the capillary tubes was obtained with the oil concentration of R-22/SUNISO 4GS oil mixture at various test conditions. The flow trends as a function of geometry and flow conditions for pure refrigerant and refrigerant/oil mixture were similar in adiabatic capillary tubes. Mass flow rate of the refrigerant/oil mixture was less than that of pure refrigerant at the same test conditions.

  • PDF

Numerical Simulation of Oil Supply System of Reciprocating Compressor for Household Refrigerators (냉장고용 왕복동 압축기 급유 시스템의 수치해석)

  • Kim, H.J.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2005
  • For a reciprocating compressor of household refrigerators, a direct analogy between the pipe flow network and the electric circuit network has been utilized to set up a mathematical model for oil supply system. Individual lubrication elements of the oil supply system, such as propeller- installed oil cap, oil galleries, radial oil feeding holes, spiral oil grooves, and various sliding surfaces have been analogized by equivalent electric elements, and these have been combined together to form an electric circuit corresponding to the whole oil supply system. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction of the numerical simulation.

  • PDF

Performance Analysis of the Lubricating Oil Feed Pump by the Anslysis of the Flow Network (유로망 해석에 의한 윤활유 공급펌프 성능 해석)

  • Kil, Doo-Song;Lee, Young-Ho
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.62-67
    • /
    • 2002
  • In this paper, the cause of the discrepancy of the inlet and outlet flow of the lubricating oil feed pump was analyzed by the flow measurement and the analysis of the flow network. At first, we thought that the flow difference was induced by a leak in the middle of the flow network. But, through the flow measurement using ultrasonic flow meter and the performance analysis of the pump, we knew that the cause of the flow difference was due to a drop in efficiency of the pump according to the pressure drop of the outlet. Also, we knew that the shape of the piping had no effect on the efficiency of the pump.

  • PDF

Numerical Study on Hydraulic Fluid Flows Within Axial Piston Pumps (액셜 피스톤 펌프내 유압유 유동에 대한 수치해석적 연구)

  • Jeong, Jong-Hyun;Kim, Jong-Ki;Suh, Yong Kweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.129-136
    • /
    • 2010
  • Axial piston pumps have been widely used as power sources for hydraulic systems, but studies on the fluid flow within the pump have been usually performed using 1-D analysis because of the difficulties in considering the fluid compressibility, high-speed revolution, variation of the flow rate, and complicated geometry. The goal of this study was to understand the hydraulic fluid flow within axial piston pumps by using the 3-D numerical method and the process of generating discharge pressure ripples. To improve the convergence and robustness of the simulation model, a grid system was constructed with hexahedron-type grids around the valve plate. Furthermore, we employed an empirical formula to describe the relationship between the oil density and pressure. The CFD (computational fluid dynamics) results compared well with the experimental data.

Runoff Characteristics and Relationship between Non-point Source Pollutants from Road (국도에서 발생하는 비점오염물질 유출특성 및 상관성)

  • Son, Hyun-Geun;Lee, So-Young;Lee, Eun-Ju;Kim, Lee-Hyung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.59-64
    • /
    • 2008
  • The urban is possessing of various landuses such as commercial, industrial, residential and official areas. All of these landuses is including the paved areas that are roads and parking lots. The NPS (nonpoint sources) pollutants are generally originated from pavement areas in urban by human activities. Especially the roads are stormwater intensive landuses because of high vehicle activities and high imperviousness. The main NPS pollutants from roads are particulates and metals from vehicles and pavements. The Korea MOE (Ministry of Environment) is developing the NPS control program to reduce the NPS pollutants from the basins. However, it is not easy to control the NPS because it has high uncertainty by characteristics of rainfalls and watersheds. Therefore, this research was conducted on characterizing the runoff and providing mean EMC from roads. The monitoring were performed for total 16 rainfall events from a road in Youngin City since 2006. The results show that the TSS is highly correlated with other pollutant parameters. The statistical regression models using TSS EMC have been developed to easily determine the EMC of other pollutant parameters.