• Title/Summary/Keyword: 오염저감

Search Result 1,427, Processing Time 0.026 seconds

Analysis on Socio-cultural Aspect of Willingness to Pay for Air Quality (PM10, PM2.5) Improvement in Seoul (서울지역 미세먼지 문제 개선을 위한 사회문화적 지불의사액 추정)

  • Kim, Jaewan;Jung, Taeyong;Lee, Taedong;Lee, Dong Kun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.2
    • /
    • pp.101-112
    • /
    • 2019
  • Over the last few years, air pollution ($PM_{10}$, $PM_{2.5}$) in the Seoul metropolitan area (SMA) has emerged as one of the most concerned and threatening environmental issues among the residents. It brings about various harmful effects on human health, as well as ecosystem and industrial activities. Governments and individuals pay various costs to mitigate the level of air pollutants. This study aims to empirically find the willingness to pays (WTP) among the parents from different socio-cultural groups - international and domestic groups to mitigate air pollution ($PM_{10}$, $PM_{2.5}$) in their residential area. Contingent Valuation Methods (CVM) is used with employing single-bounded dichotomous choice technique to elicit the respondent's WTP. Using tobit (censored regression) and probit models, the monthly mean WTP of the pooled sample for green electricity which contributes to improve air quality in the region was estimated as 3,993 KRW (3.58 USD). However, the mean WTP between the international group and domestic group through a sub-sample analysis shows broad distinction as 3,325KRW (2.98 USD) and 4,449 KRW (3.98 USD) respectively. This is because that socio-cultural characteristics of each group such as socio-economic status, personal experience, trust in institutions and worldview are differently associated with the WTP. Based on the results, the society needs to raise awareness of lay people to find a strong linkage between the current PM issue and green electricity. Also, it needs to improve trust in the government's pollution abatement policy to mobilize more assertive participation of the people from different socio-cultural background.

Disaster Risk Assessment using QRE Assessment Tool in Disaster Cases in Seoul Metropolitan (서울시 재난 사례 QRE 평가도구를 활용한 재난 위험도 평가)

  • Kim, Yong Moon;Lee, Tae Shik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.1
    • /
    • pp.11-21
    • /
    • 2019
  • This study assessed the risk of disaster by using QRE(Quick Risk Estimation - UNISDR Roll Model City of Basic Evaluation Tool) tools for three natural disasters and sixteen social disasters managed by the Seoul Metropolitan Government. The criteria for selecting 19 disaster types in Seoul are limited to disasters that occur frequently in the past and cause a lot of damage to people and property if they occur. We also considered disasters that are likely to occur in the future. According to the results of the QRE tools for disaster type in Seoul, the most dangerous type of disaster among the Seoul city disasters was "suicide accident" and "deterioration of air quality". Suicide risk is high and it is not easy to take measures against the economic and psychological problems of suicide. This corresponds to the Risk ratings(Likelihood ranking score & Severity rating) "M6". In contrast, disaster types with low risk during the disaster managed by the city of Seoul were analyzed as flooding, water leakage, and water pollution accidents. In the case of floods, there is a high likelihood of disaster such as localized heavy rains and typhoons. However, the city of Seoul has established a comprehensive plan to reduce floods and water every five years. This aspect is considered to be appropriate for disaster prevention preparedness and relatively low disaster risk was analyzed. This corresponds to the disaster Risk ratings(Likelihood ranking score & Severity rating) "VL1". Finally, the QRE tool provides the city's leaders and disaster managers with a quick reference to the risk of a disaster so that decisions can be made faster. In addition, the risk assessment using the QRE tool has helped many aspects such as systematic evaluation of resilience against the city's safety risks, basic data on future investment plans, and disaster response.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

Biopolymer Amended Soil Reduces the Damages of Zn Excess in Camlina sativa L. (토양 내 바이오폴리머 혼합에 의한 Camelina sativa L.의 Zn 과잉 스트레스 피해 경감 효과)

  • Shin, Jung-Ho;Kim, Hyun-Sung;Kim, Eunsuk;Ahn, Sung-Ju
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.262-273
    • /
    • 2020
  • Amending biopolymers such as β-glucan (BG) and Xanthan gum (XG) generally enhances soil strength by ionic and hydrogen bonds between soil particles. Thus, biopolymers have been studied as eco-friendly construction materials in levees. However, physiological responses of plants grown on soil amended with biopolymers are not fully understood. This study focuses on the effects of biopolymers on the growth of Camelina sativa L. (Camelina) under excess zinc (Zn) stress. The optimal concentrations of BG and XG were confirmed to have a 0.5% ratio in soil depending on the physiological parameters of Camelina under excess Zn stress. The Zn binding capacity of biopolymers was investigated using 1,5-diphenylthiocarbazone (DTZ). The reduction of Zn damage in Camelina was evaluated by analyzing the Zn content and expression of heavy metal ATPase (HMA) genes under excess Zn stress. Amendments of BG and XG improved Camelina growth under excess Zn stress. In DTZ staining and ICP-OES analysis, Camelina grown on BG and XG soil showed less Zn uptake than normal soil under excess Zn stress. The Zn-inducible CsHMA3 gene was not stimulated by either BG or XG amendment under excess Zn stress. Moreover, both BG and XG amendments in soil exhibit Zn-stress mitigation similar to that of Zn-tolerant CsHMA3 overexpres sed Camelina. These results indicate that biopolymer-amended soils may influence the prevention of Zn absorption in Camelina under excess Zn stress. Thus, BG and XG are proven to be suitable materials for levee construction and can protect plants from soil contamination by Zn.

A Study on Environmental Impact Assessment Guidelines for Marine Environments in Harbor Construction Projects (항만건설사업의 해양환경 환경영향평가 가이드라인 개발 연구)

  • Maeng, Junho;Kim, Taeyun;Lee, Haemi
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.3
    • /
    • pp.141-160
    • /
    • 2022
  • The harbor construction projects can lead to various marine environmental problems including habitat degradation and loss, marine water pollution, change of flow patterns, erosion, scour, sedimentation, and so on. The EIA is a measure to prevent various environmental problems in advance from examining and minimizing the environmental impacts before the proposed developments are implemented. In addition, institutions reviewing EIA reports have made efforts to conduct scientific and standardized EIA by applying EIA guidelines for each project. This study aims to create a EIA guideline focusing on the harbor construction projects. Based on the review comments of the harbor construction EIA reports for the past 13 years (2009-2021) and the EIA guidelines of different types of projects, we identified the marine environmental problems and provided the appropriate guideline. This guideline summarizes and presents the contents which must be reviewed in the baseline condition survey, impact assessment, mitigation, and post-environmental impact investigation in the fields of marine fauna and flora, marine physics, and marine water and sediment quality. In the case of a baseline condition survey of marine fauna and flora, a method for selecting survey points considering the characteristics of sea area and project was presented. When estimating the impact of marine fauna and flora, we presented methods for predicting the impact on them due to the spread of suspended sediments and the damage to benthic habitats due to dredging and reclamation. In consideration of the characteristics of the sea area, we divided the survey items of the marine physics into essential items and supplementary items. In predicting the impact of marine physics, various methods for major issues such as seawater circulation, suspended sediment and bottom sediment transport, water temperature and salinity diffusion, seawater exchange, wave transformation, harbor tranquility, and shoreline change were presented. The research results will contribute to protect the marine environment by inducing more systematic and scientific surveys, impact assessments, and mitigation in the EIA process.

Comparison of the Efficacy of Disinfectants to Control Caseous Lymphadenitis in Korean Black Goat Farms (흑염소의 건락성 림프절염 제어를 위한 소독제 효능 비교)

  • Cho, Hyeunwoo;Kim, Yeona;Jang, Beomsoon;Kim, Chan-Lan;Park, Kun Taek
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.317-322
    • /
    • 2022
  • Corynebacterium pseudotuberculosis is the causative agent of caseous lymphadenitis (CLA), a chronic contagious disease in small ruminants. The prevalence of CLA has been reported to be >50% in Korean black goats. CLA is difficult to control due to a lack of efficient vaccines and treatment methods. Effective disinfection of the farm environment may be an alternative strategy for reducing the spread of C. pseudotuberculosis. The objective of this study was to evaluate the efficacy of commercial disinfectants against CLA. The six commercial disinfectants, largely composed of sodium dichloroisocyanurate, sodium hypochlorite, potassium monopersulfate triple salt, quaternary ammonium, citric acid, and copper sulfate, were tested against five different genotypes of C. pseudotuberculosis isolated from goat farms in Korea. Efficacy tests were performed in accordance with the disinfectant efficacy test guidelines recommended by the Animal and Plant Quarantine Agency of Korea with slight modifications. All disinfectants except for copper sulfate exhibited >99.99% killing efficacy under hard water conditions following 30 min of incubation, which is the recommended standard treatment time according to guidelines. The minimum bactericidal treatment time was evaluated by employing treatments for durations of 1, 5, and 15 min. The most effective compounds under hard water conditions were sodium dichloroisocyanurate, potassium monopersulfate triple salt, and sodium hypochlorite, exhibiting >99.99% killing efficacy after 1 min of treatment. In the aqueous solution forms, citric acid and the quaternary ammonium compound were the most effective, but required at least 5 min to kill >99.99% of the bacteria. The current study characterizes the killing efficacy of six commercial disinfectant active compounds against C. pseudotuberculosis. Thus, this study provides essential information regarding the efficacy of the disinfectants used to control CLA in goat farms.

Characteristics of Flue Gas Using Direct Combustion of VOC and Ammonia (휘발성 유기 화합물 및 암모니아 직접 연소를 통한 배기가스 특성)

  • Kim, JongSu;Choi, SeukCheun;Jeong, SooHwa;Mock, ChinSung;Kim, DooBoem
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • The semiconductor process currently emits various by-products and unused gases. Emissions containing pollutants are generally classified into categories such as organic, acid, alkali, thermal, and cabinet exhaust. They are discharged after treatment in an atmospheric prevention facility suitable for each exhaust type. The main components of organic exhaust are volatile organic compounds (VOC), which is a generic term for oxygen-containing hydrocarbons, sulfur-containing hydrocarbons, and volatile hydrocarbons, while the main components of alkali exhaust include ammonia and tetramethylammonium hydroxide. The purpose of this study was to determine the combustion characteristics and analyze the NOX reduction rate by maintaining a direct combustion and temperature to process organic and alkaline exhaust gases simultaneously. Acetone, isopropyl alcohol (IPA), and propylene glycol methyl ether acetate (PGMEA) were used as VOCs and ammonia was used as an alkali exhaust material. Independent and VOC-ammonia mixture combustion tests were conducted for each material. The combustion tests for the VOCs confirmed that complete combustion occurred at an equivalence ratio of 1.4. In the ammonia combustion test, the NOX concentration decreased at a lower equivalence ratio. In the co-combustion of VOC and ammonia, NO was dominant in the NOX emission while NO2 was detected at approximately 10 ppm. Overall, the concentration of nitrogen oxide decreased due to the activation of the oxidation reaction as the reaction temperature increased. On the other hand, the concentration of carbon dioxide increased. Flameless combustion with an electric heat source achieved successful combustion of VOC and ammonia. This technology is expected to have advantages in cost and compactness compared to existing organic and alkaline treatment systems applied separately.