• Title/Summary/Keyword: 오염된 공기

Search Result 885, Processing Time 0.025 seconds

Evaluation of a Diffusive Sampler for the Measurement of Formaldehyde using Colorimetric Method (흡광광도법을 이용한 포름알데히드 확산측정기의 평가)

  • Yim, Bong-Been;Kim, Sun-Kyu;Jung, Eui-Suk;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.606-613
    • /
    • 2005
  • The badge-type diffusive sampler for the measurement of formaldehyde in indoor air using three types of colorimetric methods such as chromotrophic acid(CTA), 3-methyl-2-benzothiazolinone hydrazone(MBTH), and 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole(AHMT) method. The washing of the collection filter with several cleaning solution was effected with satisfactory results, regardless of the types of cleaning solutions. The concentrations of absorbance solution in each colorimetric method were experimentally determined by considering the sampling rates. The variation blank values in each colorimetric method was below 15%. As compared with CTA and AHMT methods, the reproducibility of MBTH method was excellent and was below 10% relative standard deviation. The collected formaldehyde mass and time-weighted concentration had a good correlation (correlation coefficient > 0.93). The limit of detection and limit of quantitation, and minimum sampling time were closely correlated to the sampling rates for the measurement of formaldehyde in each method.

Signal Processing for Stabilizing Output of Fine Dust Sensor (미세먼지 센서 출력의 안정화를 위한 신호처리)

  • Jung, Sang-Wook;Park, Jun-Hyeon;Kim, Ju-An;Kim, Jae-Wook;Cheon, Bong-Won;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.344-346
    • /
    • 2018
  • Air pollution has become a social issue. Particularly, interest in fine dust is increasing. Various kinds of sensors are being used to measure fine dust. The most commonly used infrared detection dust sensors operate by sensing the diffraction of light through an infrared receiver and sensing the light reflected by the dust in the air. However, this method has a drawback in which accurate data analysis is difficult due to deviation caused by the noise during measurement. In order to overcome such drawbacks, in this thesis, a low pass filter algorithm of FIR(Finite Impulse Response) filter was designed and implemented.

  • PDF

Unrecorded Fungal Species Isolated from Greenhouses Used for Shiitake Cultivation in Korea (표고버섯 재배사에서 분리한 국내 미기록 진균 보고)

  • Ahn, Geum Ran;Kwon, Hyuk Woo;Ko, Han Kyu;Kim, Seong Hwan
    • The Korean Journal of Mycology
    • /
    • v.44 no.1
    • /
    • pp.8-15
    • /
    • 2016
  • Fungal contamination is a detrimental factor affecting sawdust media-based shiitake cultivation in greenhouses. During fungal monitoring of greenhouses used for shiitake cultivation, eight fungal species were isolated and identified from indoor air and mushroom flies collected in the greenhouses. The current study reported five species as new in Korea, viz. Ascochyta hordei, Discosia artocreas, Mucor nidicola, Perenniporia medulla-panis, and Pseudozyma prolifica, and confirmed two species, Penicillium charlesii and Penicillium brevicompactum, which were previously recorded in Korea without molecular taxonomic validation. The morphological characteristics and phylogenetic relationships based on nucleotide sequences of the internal transcribed spacer rDNA region or calmodulin gene were described for all identified species.

TPH Removal of Oil-Contaminated Soil by Hot Air Sparging Process (고온 공기분사공정에 의한 유류오염대수층의 TPH 제거)

  • Lee, Jun-Ho;Park, Kap-Song
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.665-675
    • /
    • 2007
  • In-situ Air Sparging (IAS, AS) is a remediation technique in which organic contaminants are volatilized from saturated zone to unsaturated layer. This study focuses on the removal and interaction of Volatile Organic Compounds (VOCs) and $CO_2$, and Total Petroleum Hydrocarbon (TPH) in saturated and unsaturated, and air space zone on the unsaturated soil surface. Soil sparging temperature of hot air has risen to $34.9{\pm}2.7^{\circ}C$ from $23.0{\pm}1.9^{\circ}C$ for 36 days. At the diffusing point, fluid TPH concentrations were reduced to 78.7% of the initial concentration in saturated zone when hot air was sparged. The TPH concentrations were decreased to 66.1% for room temperature air sparging. The amount of VOCs for hot air sparging system, in air space, was approximately 26% larger than constant air sparging system. The amount of $CO_2$ was 4,555 mg (in unsaturated zone) and 4,419 mg (in air space) when hot air was sparged was 3,015 mg (in unsaturated zone) and 3,634 mg (in air space) for room air temperature in the $CO_2$ amount. The removals of VOCs and biodegradable $CO_2$ through the hot air sparging system (modified SVE) were more effective than the room temperature air sparging. The regression equation were $Y=976.4e^{-0.015{\cdot}X}$, $R^2=0.98$ (hot air sparging) and $Y=1055e^{-0.028{\cdot}X}$, $R^2=0.90$ (room temperaure air sparging). Estimated remediation time was approximately 500 days, if final saturated soil TPH concentration was set to 1.2 mg/L application of tail effect.

A Study on the Indoor Air Pollution in the Classrooms of Primary, Middle and High Schools in Seoul and Gyeonggi-Do (서울.경기지역 초.중.고등학교 교실의 실내공기오염에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Moon, Jeong-Suk;Kim, Sang-Uk
    • Journal of the Korean Society of School Health
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2003
  • This study was conducted to contribute to the basic data for decisions on environment policy improvement in health promotion for students in elementary, middle and high schools. This study was carried out to investigate the extent of indoor air pollution in elementary, middle and high schools in residential, traffic congestional and industrial areas. The concentrations of major indoor air pollutants(carbon monoxide, carbon dioxide, respiratory particulate, radon) and thermocircumstance (temperature, relative humidity, intensity of illumination) indices were observed from June to August 2000. As results of the survey, the mean values of thermocircumstance in school were $26.94{\pm}1.15^{\circ}C$ of temperature, $68.88{\pm}5.31%$ of humidity and $268.26{\pm}164.60$ Lux of intensity of illumination. The mean concentrations of carbon monoxide, carbon dioxide, respiratory particulate were $8.36{\pm}0.29\;ppm$, $547.66{\pm}175.58\;ppm$, $36.23{\pm}48.39\;{\mu}g/m3$, respectively. These values were lower than those of the indoor environmental standard on the first clause of Article 45 of public utilization service notified public hygiene of the Ministry of Health and Social Affairs. The mean concentration of radon was $20.07{\pm}17.95\;Bq/m3$. Which was below the U.S. EPA radon action level.

Environmental Sensor Monitoring System of Subway Stations Using USN (USN을 이용한 지하철 역사 대기환경 모니터링 시스템)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • The$PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, an USN monitoring system is implemented to display and record the data of $PM_{10}$, CO/$CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, 2.4GHz Zigbee, 424MHz wireless communication, and CDMA M2M method are applied and evaluated.

Childrens' Health Risk Assessment on Indoor Hazardous Air Pollutants of Preschool Facility (유아교육시설 내 실내공기유해오염물질에 대한 어린이 건강위해성평가)

  • Koh, Yeon-Jung;Kim, Shin-Do;Park, Suk-Young;Jang, Seong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.78-85
    • /
    • 2009
  • In this study, the hazard rate of the indoor environment of Children's Educational Facilities in Seoul was conducted, in order to determine how the indoor environments of these facilities, where infants and children spend the most time of their away from home day, can effect their health. The way of measurement and analysis were done according to the Indoor Air Quality Standard Method, and the Risk Assessment was accomplished with several significant ways - Hazard Identification, Exposure Assessment, Dose-response Assessment, Risk Characterization, which are deighed by National Research Council (NRC). On each exposure factors, documentary and questionary research such as Epidemiological study and Toxicological study were conducted. The result of the CTE (Central tendency exposure) of Formaldehyde and Benzene by Monte-Carlo simulation was $6.79{\times}10^{-6}$, $2.50{\times}10^{-7}$ which in the case of Formaldehyde exceeded the permitted standard ($10^{-6}$) of the US EPA. The RME(Reasonable maximum exposure) was $7.31{\times}10^{-5}$, $2.65{\times}10^{-6}$ which did not exceed $10^{-4}$, the maximum permitted standards in the US EPA.

Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter (겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염)

  • Kim, Jong Bum;Lee, Gwangjae;Ryu, Sung Hee;Lee, Jae Young;Woo, Sung-Ho;Lee, Seung-Bok;Kim, Kyung Hwan;Yun, Seong-Taek;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

Study on the Properties of Light-weight Concrete containing Bottom Ash as a part of Fine Aggregate (바텀애시를 잔골재로 사용한 경량콘크리트의 특성에 관한 연구)

  • Lee, Jin-Woo;Kwon, Hae-Won;Park, Hee-Gon;Kim, Yoo-Jin;Bae, Yeoun-Ki;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.701-704
    • /
    • 2008
  • Actuality, amount of electric power is rising together with business expansion. But the most power plant is consisted a thermal power. People have been burning fuel like a coal, and it bring the cinder concrete. Fly-ash is use to the high-degree in construction material, but in case of bottom-ash had been disused the whole quantity. Intermittently, the academic world laid his studies for bottom-ash. Thus, this study contents are a characteristic of be not harden concrete incorporating fine aggregate, a strength of harden concrete, elastic modulus and a unit mass. And there do for the sake to examine utility value of bottom-ash and improve of light weight concrete.

  • PDF

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.