• 제목/요약/키워드: 오염(contamination)

검색결과 2,354건 처리시간 0.026초

Groundwater Contamination at the Seokdae Waste Landfill Area of Pusan City (부산 석대 폐기물 매립장 일대의 지하수 오염)

  • 정상용
    • Journal of the Korean Society of Groundwater Environment
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 1995
  • Wastes produce groundwater contamination, offensive odor, and hazardous gases. This study investigates the contamination of groundwater at the Seokdae waste landfill area and seeks the desirable ways to minimize the groundwater contamination. Groundwater levels, water chemistry and aquifer characteristics of wells were examined around the Seokdae waste landfill. The water chemistry of the Dong stream, the groundwater distribution and flow were also studied. The results of this research show that the estimated quantity of the percolation from the landfill base to the ground is 520 ㎥/day and the extent of groundwater contamination is about 1-1.5 km from the center of the waste landfill. The groundwater contains heavy metals and other toxic elements. The conservation and management of the groundwater of the waste landfill need several monitoring wells to check the quantity and quality of groundwater, pumping wells to extract the contaminated groundwater, and slurry walls to protect the movement of contaminated groundwater.

  • PDF

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제21권6호
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

SHEAR BOND STRENGTH OF SELF-ETCHING PRIMER SYSTEMS TO CONTAMINATED DENTIN IN PRIMARY TEETH (오염된 유치 상아질에 대한 자가 부식 프라이머의 결합강도에 관한 연구)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eup
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제29권1호
    • /
    • pp.107-114
    • /
    • 2002
  • The purpose of this study was to determine and compare the shear bond strength of two self-etching primer systems to primary teeth contaminated with saliva and blood. Clearfil SE Bond and AQ Bond were evaluated. One hundred specimens were made by seventy-five deciduous teeth(fifty anterior and twenty-five posterior teeth) and divided randomly into ten groups. Small flat dentinal surfaces were prepared by grinding the buccal, lingual and labial areas. Specific surface treatments were applied to each group: (1) a self-etching primer application(control group), (2) saliva contamination followed by primer(Group I), (3) primer curing followed by saliva contamination (Group II), (4) blood contamination followed by primer(Group III), (5) primer curing followed by blood contamination(Group IV). After bonding of composite resin(Z100, 3M, USA) to contaminated sample surfaces and thermocycling(1,000 cycles), shear bond strengths were measured using Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results were as follows; 1. Group I showed lower shear bond strength than control group but no statistically significant difference was found(P>0.05). 2. Group II and blood contamination group(Group III & IV) showed significantly lower shear bond strength than control group(P<0.01). 3. The shear bond strength of Clearfil SE Bond was significantly higher than that of AQ Bond(P<0.05).

  • PDF

Survey on Fusarium Mycotoxin Contamination in Oat, Sorghum, Adlay, and Proso Millet during the Harvest Season in Korea (귀리, 수수, 율무, 기장의 수확기에 발생하는 Fusarium 곰팡이독소 오염도 조사)

  • Lee, Mi Jeong;Wee, Chi-Do;Ham, Hyenheui;Choi, Jung-Hye;Baek, Ji Sun;Lim, Soo Bin;Lee, Theresa;Kim, Jeom-Soon;Jang, Ja Yeong
    • Journal of Food Hygiene and Safety
    • /
    • 제35권1호
    • /
    • pp.13-22
    • /
    • 2020
  • A total of 244 cereal samples (oat, sorghum, adlay, and proso millet) were collected from fields to examine the contamination of Fusarium mycotoxins in cereals during harvest season in 2017 and 2018. The contamination levels of deoxynivalenol (DON), nivalenol (NIV), and zearalenone (ZEA) were analyzed individually by using the immunoaffinity column clean-up method with ultra performance liquid chromatography, and fumonisins (FUM) were analyzed by using the QuEChERS method with liquid chromatography-mass spectrometry. Highest level of NIV contamination (120.0-3277.0 mg/kg) was observed in oat samples among the analyzed cereals. In the adlay samples, DON contamination was the highest (maximum level 730.0 ㎍/kg). The proso millet samples had a high frequency of detection of NIV and ZEA (61.5% and 57.9%, respectively), but the levels were low (average detection level of NIV, 75.6 ㎍/kg, for ZEA, 21.5 ㎍/kg). Among the cereal samples, sorghum had the highest contamination frequency of DON, ZEA, and FUM, and the co-occurrence of Fusarium mycotoxin was 70.0%, which was higher than the average of 29.9%. In order to safely manage Fusarium mycotoxin levels in cereals, continuous research on the development of contamination prevention technologies together with monitoring of mycotoxin contamination is needed.

Factors affecting the contamination of bag urine culture in febrile children under two years (2세 미만의 열성 환아에서 소변 주머니를 이용한 소변 배양 검사의 오염률에 영향을 미치는 인자)

  • Choi, Wook Hyun;Lim, In Seok
    • Clinical and Experimental Pediatrics
    • /
    • 제52권3호
    • /
    • pp.346-350
    • /
    • 2009
  • Purpose : Since children under two years with suspected urinary tract infections (UTIs) cannot control urination, urine cultures in such children are usually performed via urine bags. This method is noninvasive but has a high contamination rate. We studied the contamination rate of bag urine culture in diagnosing UTI in infants under two years and the factors responsible for contamination. Methods : We examined patients under 2 years in whom urine culture through the urine bag method yielded over 105 colonies of a single pathogen. We defined UTI by referring to the guidelines of The Korean Society of Pediatric Nephrology, 2005. We examined the factors responsible for contamination according to sex, duration of urine collection, and whether diarrhea took place with contamination rate. Results : We examined 717 patients (412 males and 305 females). The contamination rate of one bag urine culture was 37.9%. Gender was not related to the contamination rate (P>0.05). Duration of urine collection showed an association with the contamination rate. The longer the duration of collecting urine, the higher was the contamination rate. Duration of urine collection was divided into three groups: first group, <2 hours; second group, 24 hours; and third group, ${\geq}4$ hours. Contamination rates were 30.0%, 42.2%, and 43.7% for the first, second, and third groups, respectively, with statistical significance (P=0.001). Diarrhea at admission had no impact on the contamination rate (P>0.05). Conclusion : The contamination rate of urine culture in the examined patients was 37.9%. Gender and diarrhea symptoms were not responsible for contamination. In infants with a suspected UTI, urine should be collected within 2 hours through the urine bag method. If urine collection takes >2 hours, the urine bag should be resterilized and reattached to the patient.

Experimental Evaluation on Occurrence Possibility of Pollutants from Aggregates (순환골재의 오염물질 발생 가능성에 관한 실험적 평가)

  • Park, Jeong-Ho;Seong, Jin-Uk;Park, Je-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제1권1호
    • /
    • pp.1-7
    • /
    • 2013
  • This study was on leaching test(KSLT, TCLP) of the aggregate for the products(RA-1) and for the site(RA-2) to evaluate the characteristics of contaminants and the possibility of contamination arising from the aggregate. On the basis pH, conductivity and heavy metal contents in the aggregate, RA-1 indicated higher than RA-2. As a result of the leaching test, the pollutants were eluted from the aggregate increased as the particle size of the aggregate was smaller. The pH in the aggregate had a strong alkali by a pH value of 9.0~12.3, the conductivity was higher in less than 10mm RA-1 due to the leaching of dissolved inorganic ions. The heavy metals satisfied the leaching standards of KSLT and less 10% was eluted from the aggregate. As a result of evaluating water pollution possibility of the aggregate, the pH displayed in items with a very high possibility of contamination, conductivity and turbidity did in item with a low possibility of contamination and on the other hand the heavy metals did in item with a very low possibility of contamination.

Contamination structure and process on SUS 316 under UHV, HV and air (초고진공, 고진공, 대기압에서 SUS 316의 오염 구조와 오염 과정 연구)

  • 서지근;이규장;신용현;홍승수;정광화
    • Journal of the Korean Vacuum Society
    • /
    • 제6권1호
    • /
    • pp.1-8
    • /
    • 1997
  • The contamination structure and process on SUS 316 under various exposure conditions were investigated using x-ray photoelectron spectroscopy. The metal-oxide, metal-H-oxides, CO, COH, and $C_xH_y$ are the main components of contaminants on the SUS surface. The compositional profiles of the contaminants are shown to be $C_xH_y$/CO(COH)/metal-oxide on SUS. The contamination proceeds in two steps. The oxidation of the metallic constituents followed by adsorption of hydrocarbons. Under UHV conditions the contamination is mainly due to the oxidation, and, as the exposure time increases, the oxidation continues. In HV or higher pressure, most of the oxides are formed almost immediately after exposure and as the exposure time increases the contamination of hydrocarbons continues to grow. For the SUS sample exposed to atmosphere, the metal oxide is distributed deep inside the surface with an exponentially decreasing concentration, and its thickness is nearly in the order of photoelectron mean free path. It is also seen that the Fe oxide is segregated over Cr oxide in the highly oxidized samples.

  • PDF

A Study on the Prediction of Groundwater Contamination using the GIS in Hwanam 2 Sector, Gyeonggi Province, Korea (GIS를 이용한 경기도 화남2지구의 지하수오염 예측에 관한 연구)

  • Son, Ho-Ung
    • The Journal of Engineering Research
    • /
    • 제5권1호
    • /
    • pp.89-107
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and landuse, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Whanam 2 Area, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Composite contamination map was achieved as a final result by comparing modified DRASTIC potential and the amount of generation load of several contaminant sources logically. The result could suggest the predictability of the area of contamination potential on the respects of hydrogeological aspect and water quality.

  • PDF

Improving Soil Environment Policy to Build New Greenfield at Brownfield Redevelopment Projects (기훼손(오염)지역에서의 재개발사업 사례를 통해서 본 토양환경개선방안)

  • Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • 제13권6호
    • /
    • pp.103-107
    • /
    • 2008
  • In this work, soil environment policy which should be taken into account at brownfield redevelopment projects was deduced from investigation on their environmental impact assessment statements. Soil contamination sources such as small-scale factories were found at a few large-scale brownfield projects, so contaminated soils did often exist at these sites. Especially, military facilities within the sites caused severe soil contamination problems. Therefore, soil environment policy was presented in detail to solve soil contamination problem at brownfield redevelopment projects. Furthermore, land-use planning focusing on greening (soil and vegetation) should be pursued at brownfield redevelopment projects in order to maximize environmental benefits of greenspace.