• 제목/요약/키워드: 오염(contamination)

검색결과 2,354건 처리시간 0.025초

A Study on the 3-D Airflow and Dynamic Cross Contamination in the Photolithography Process Cleanroom (광식각공정이 있는 클린룸에서의 3차원 기류 및 동적교차오염에 관한 연구)

  • Noh, Kwang-Chul;Oh, Myung-Do;Lee, Seung-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제28권5호
    • /
    • pp.560-568
    • /
    • 2004
  • We performed the numerical study on the characteristics of the 3-D airflow and dynamic cross contamination in the photolithography process cleanroom. The nonunifurmity, the deflection angle and the global cross contamination were used for analyzing the characteristics and performances of cleanroom. From the numerical results, we knew that the airflow characteristics of the cleanrooms are largely affected by the porosity of panel and the adjustment of dampers and the global cross contamination varies with the location of source and the passage of time through the concentration ratio.

A Numerical Study on the Characteristics of Airflow and Cross Contamination in the Photolithography Process Cleanroom (광식각공정 클린룸에서의 기류 및 교차오염에 대한 수치적 연구)

  • Noh, Kwang-Chul;Lee, Seung-Chul;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.151-156
    • /
    • 2003
  • We performed the numerical study on the characteristics of the airflow and cross contamination in the photolithography process cleanroom. The nonuniformity, the deflection angle and the global cross contamination were used for analyzing the characteristics and performances of cleanroom. We knew that the airflow characteristics of the cleanrooms are largely affected by the porosity of panel and the adjustment of dampers. And the numerical result showed that the global cross contamination varies with the location of source and the passage of time.

  • PDF

Management Criteria of Underground Strage Tank for Prevention of Soil Contamination (토양오염방지를 위한 지하저장탱크의 관리 방안 연구)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • 제18권
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

Evaluation of Heavy Metal Contamination in Streams within Samsanjeil and Sambong Cu Mining Area (삼산제일.삼봉 동광산 주변 수계의 중금속 오염도 평가)

  • Kim, Soon-Oh;Jung, Young-Il;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.171-187
    • /
    • 2006
  • The status of heavy metal contamination was investigated using chemical analyses of stream waters and sediments obtained from Samsanjeil and Sambong Cu mining area in Goseong-gun, Gyeongsangnam-do. In addition, the degree and the environmental risk of heavy metal contamination in stream sediments was assessed through pollution index (Pl) and danger index (DI) based on total digestion by aqua regia and fractionation of heavy metal contaminants by sequential extraction, respectively. Not only the degree of heavy metal contamination was significantly higher in Samsanjeil area than in Sambong area, but its environmental risk was also revealed much more serious in Samsanjeil area than in Sambong area. The differences in status and level of contamination and environmental risk between both two mining areas may be attributed to existence of contamination source and geology. Acid mine drainage is continuously discharged and flows into the stream in Samsanjeil mining area, and it makes the heavy metal contamination in the stream more deteriorated than in Sambong mining area in which acid mine drainage is not produced. In addition, the geology of Samsanjeil mining area is mainly comprised of andesitic rocks including a small amount of calcite and having lower pH buffering capacity fer acid mine drainage, and it is likely that the heavy metal contamination cannot be naturally attenuated in streams. On the contrary, the main geology of Sambong mining area consists of pyroclastic sedimentary Goseong formation containing a high content of carbonates, particularly calcite, and it seems that these carbonates of high pH buffering capacity prevent the heavy metal contamination from proceeding downstream in stream within that area.

Analysis of Jet Fuel for the Judgment of Soil Polluter (토양오염 원인자 판단을 위한 항공유 분석)

  • Lim, Young-Kwan;Jeong, Choong-Sub;Han, Kwan-Wook;Jang, Young-Ju
    • Applied Chemistry for Engineering
    • /
    • 제25권1호
    • /
    • pp.27-33
    • /
    • 2014
  • The significance of soil environment is gradually increased due to the soil and underwater contamination caused by petroleum leak accidents. It requires a high cost and long period for the purification of soil compared with other environmental matrix such as water and air. For this reason, it has been embroiled in a legal conflict to find the pollution source and charge of cleanup. In this study, we analyzed the physical properties and typical additives of jet fuel to search a method that can distinguish kerosene and jet fuel contamination. In particular, the chemical marker in kerosene was visualized by the developer and the additives in jet fuel, such as antioxidant and metal deactivator were detected by GC-MS. This study could be used to judge petroleum source at soil contaminant accident sites.

A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter (전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.37-42
    • /
    • 2009
  • Whole body counters (WBCs) are used to monitor radiation workers for internal contamination of radionuclides at domestic nuclear power plants (NPPs). A WBC is a scintillation detector using sodium iodide (NaI) and provides the identification of inhaled radionuclide and the measurement of its internal radioactivity in a short time. However, it is often possible to estimate external contamination as internal contamination due to radionuclides attached to the skin of radiation workers and this leads to an excessively conservative estimation of radioactive contamination. In this study, several experiments using a WBC and the Korean humanoid phantom were performed to suggest the more systematic method of discrimination between external and internal contamination. Furthermore, a WBC geometry experiment was conducted to suggest the optimal WBC geometry in consideration of deposited areas inside the body for dominant radionuclides at NPPs. The procedure of measurement and estimation of internal radioactivity for radiation workers at NPPs was improved on the basis of experimental results. Thus, it is expected to prevent from estimating internal exposure dose conservatively owing to the application of accurate whole body counting program to NPPs.

Prevention of Microbial Contamination Through Monitoring of the Harvesting, Sorting, and Distribution Stages of Fresh Hot Pepper (신선 고추의 수확, 선별 및 유통 단계에서의 미생물 모니터링 및 미생물 오염 저감화 방법 모색)

  • Kim, Sol-A;Lee, Jeong-Eun;Park, Hyun-Jin;Lee, Sang-Dae;Moon, Hyo-Yeong;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • 제35권1호
    • /
    • pp.60-67
    • /
    • 2020
  • This study determined the microbial contamination levels of hot pepper at harvest, sorting, and distribution stages to suggest a way of reducing the microbial contamination of hot peppers by changing work gloves used throughout these processes. According to the monitoring results, the contamination levels of total aerobic bacteria (TAB) were found in the following order: soil (5.3±0.9 log CFU/g), hot pepper (4.2±0.9 log CFU/g), gloves (4.2±0.6 log CFU/g), baskets (4.1±0.7 log CFU/ g), clippers (3.9±0.6 log CFU/ g) and water (3.2±1.1 log CFU/g) at harvest stage. The contamination level of coliforms were found in the following order: soil (2.2±0.9 log CFU/g), hot pepper (2.2±0.3 log CFU/g), gloves (2.1±0.6 log CFU/g), clippers (2.0±0.21 log CFU/ g) and baskets (1.9±1.1 log CFU/ g) at harvest stage. TAB on hot pepper at the harvest stage was reduced from 4.2±0.9 log CFU/g to cold storage 3.8±0.2 log CFU/g and room temperature storage 2.6±0.3 log CFU/g, respectively. By the replacement of work gloves and lower distribution temperature, TAB levels of the peppers were significantly reduced compared to those without replacement and distributed at room temperature. In addition, the utilization of plasma was effective on reducing microbial contamination of hot pepper. These results demonstrated that appropriate replacement of gloves at the harvest stages, using plasma in the distribution stage, and refrigerated distribution conditions, which are simple and easy to practice in the field, are effective to reduce microbial contamination on hot peppers.

다목적실용위성 2호 입자오염해석

  • Han, Dong-In
    • Aerospace Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.80-88
    • /
    • 2003
  • The present analysis quantifies the particulate contamination of KOMPSAT-2 satellite until in orbit life. Assumptions are defined about integration and test conditions and durations, then a budget is drawn. As KOMPSAT-2 activities are carried out in good cleanliness conditions, the particulate contamination budgets for satellite and instrument surfaces at BOL is fair. To summarise, in the baseline launch conditions (class 10,000) the contribution of satellite AIT and launch activities adds 500 PPM to MSC and STA apertures (telescope mirrors ; front lens ; baffle), 20,000 PPM to MSC and STA outer surfaces, 14 000 PPM to plate-form horizontal surfaces, 1400 PPM to plate-form vertical surfaces, 1000 PPM to plate-form radiators and less than 300 PPM to solar arra.

  • PDF

Heavy Metal Concentrations in Soils and Crops in the Poongwon Mine Area (풍원광산 지역의 토양 및 농작물 중금속 오염)

  • Kim, Jakwan
    • Journal of the Korean GEO-environmental Society
    • /
    • 제11권2호
    • /
    • pp.5-11
    • /
    • 2010
  • Abandoned mines release acid mine drainage and cause the contamination of soil and crops around the mine area. The objective of current study is to evaluate effect of mine on the soil and crop contamination. Soils, water, and crops were collected and analyzed, and the heavy metal data were classified into types of the soil, types of crops, and distance from the minehead. Surface soils of the mine area were highly contaminated with heavy metals, especially with zinc and lead. Tailings and cultivated paddy soils were also highly contaminated. Heavy metal concentrations upon distance from minehead decrease steadily as the distance from the minehead increase. The correlation between heavy metals was extracted from soils and the content in the rice samples showed a positive relation for arsenic and cadmium but not a meaningful relation for other metals.