• Title/Summary/Keyword: 오리피스형

Search Result 98, Processing Time 0.021 seconds

A Study on Discharge Characteristics from the Nozzle Orifice Attached to a Modularized Fire Extinguishing Gas-agent Container Under Horizontal Position (용기 일체형 가스소화 방식의 오리피스 방사 특성에 관한 연구)

  • 김윤증;윤명오;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.59-69
    • /
    • 2002
  • The conventional fire extinguishing gas-agent system has a configuration in which the gas-agent comes out of a cylindrical container having vertically settled shape. However, in this study a horizontally installed container of a piping shape having a cylinder of the same shape with a cylinder valve and a discharge nozzle was used, and the relationship between orifice size of nozzle and discharge rate of gas-agent was investigated through various experiments including the measurement of discharge rate under different ambient-temperature conditions. In such experiments, HCFC Blend A was used without super-pressurization by nitrogen. From this research, it was observed that statutory discharge duration of 10 seconds can be met if the relatively large size of the valve and the nozzle orifice were properly selected.

Investigation for Spray Characteristics of Dual Swirl Injector (이중 스월 인젝터의 분무특성에 관한 연구)

  • Park Hee Ho;Jeong Chung Yon;Kim Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.1
    • /
    • pp.17-26
    • /
    • 2005
  • Both numerical analysis and cold tests for the swirl coaxial type injector were performed to obtain the influence of spray angle, velocity ratio and liquid film thickness for pressure drop and recess. The basic experimental and numerical data obtained in this study can be applicable to the performance design of swirl coaxial type injector. Spray angle was not affected by the applied test pressure drop, but spray angle was affected by tangential velocity ratio and shape factors. Feasibility of numerical analysis for the liquid film thickness and spray angle was confirmed, and the change of liquid film thickness by tangential velocity ratio affected more seriously than pressure drop, and liquid film thickness was decreased with increasing tangential velocity ratio.

Numerical Analysis for the Pressure and Flow Fields past a Two-Staged Conical Orifice (이단 원추형 오리피스를 지나는 압력장과 유동장에 관한 수치적 연구)

  • Kim, Yeon-Su;Kim, Yu-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.278-287
    • /
    • 2002
  • The objective of the paper was to calculate the pressure drop and to investigate the recirculation region of the conical orifices used in Kwang-yang Iron & Steel Company. The flow field with water used as a working fluid was the turbulent flow for Reynolds number of 2$\times$10$^4$. The effective parameters fur the pressure drop and the recirculation region were the conical orifice\`s inclined angle ($\theta$) against the wall, the interval(S) between orifices, the relative angle of rotation($\alpha$) of the orifices, the shape of the orifice's hole(circle, rectangle, triangle) having the same area, the number(N) of the orifice's holes having the same mass flow rate, and the thickness(t) of the orifices. It was fecund that the shape of the orifice's hole, the number of the orifice's holes and the thickness of the orifice affected the total pressure drop a lot and that the conical orifice's inclined angle against the wall, the relative angle of rotation of the orifices, the number of the orifice's holes and the thickness of the orifices affected the center location of the recirculation region. The PISO algorithm with FLUENT code was employed to analyze the flow field.

Optimization of flow performance by designing orifice shape of outdoor unit of air-conditioner (에어컨 실외기 냉각팬 시스템의 오리피스 형상 설계를 통한 유량 성능 최적화)

  • Ryu, Seo-Yoon;Kim, Sanghyeon;Cheong, Cheolung;Kim, Jong-Uk;Park, Byeong Il;Park, Se Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.371-377
    • /
    • 2017
  • The performance of an air conditioner is closely related to the cooling performance of a split-type outdoor unit so that, in most of the relevant preceding studies, the independent performance of an axial fan in an outdoor unit has been studied. However, there is a lack of research on the effects of other components in an outdoor units was rarely investigated. Therefore, in this paper, the effects of the fan orifice among other parts on the flow performance of the outdoor unit was numerically investigated. A virtual fan tester consisting of 18 million grids was developed for highly resolved flow simulation. The unsteady RANS (Reynolds-averaged Navier-Stokes) equations are numerically solved by using finite-volume CFD (Computational Fluid Dynamics) techniques. In order to verify the validity of the numerical methods, the predicted P-Q curve of the cooling fan in a full outdoor unit is compared with the measured one. Optimization of orifice shape was carried out for maximum flow performance of the outdoor unit using the validated numerical method.

Pressure Drop in a Helical Square Duct (나선형 사각덕트 내의 압력강하)

  • Ryu, Seung-Yeob;Yoon, Juh-Yeon;Lee, Doo-Jeong
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.398-403
    • /
    • 2001
  • Pressure drop at a helical square duct orifice is numerically evaluated. The orifice is installed at the entrance of a once-through steam generator tube to suppress flow instabilities. The calculated results are compared with the available experimental correlations, and showed good agreement. Effects of curvature ratio and characteristics of the secondary flow with Reynolds number are reported. Through the numerical simulations, pressure drop mechanisms were well understood inside the compact and complicated orifice geometry.

  • PDF

Development of Management Model for Efficient Reservoir Operation System (효율적 저수지 운영시스템 구축모형의 개발)

  • Jang, Su-Hyung;Yoon, Jae-Young;Ahn, Jae-Hyun;Kim, Won-Seock;Yoon, Yong-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1460-1465
    • /
    • 2005
  • 본 연구에서는 장수형 등(2005)이 제시한 실시간 저수지 유입량 예측모형과 통합하여 하나의 시스템을 구축한 후 하류 하도의 홍수통수능력과 현재 저수지 수위에서 방류 가능량을 고려하여 수문에서의 조절 방류 방안을 제시하였다. 또한, 현재시간 이후로 유입되는 홍수량을 감안하여 강우가 종료되어서도 이수용량이 확보되도록 하였다. 연구는 예당저수지에 적용하였으며, 방류량 계산시 최대 방류가능량은 저수위와 수문의 개도고에 따라 오리피스와 완전월류 흐름을 구분하여 계산하였으며 방류기준은 하류 하도의 통수능력, 강우종료 후 이수용량 확보 등을 감안하여 결정하였다. 연구의 적용결과, 본 연구에서 개발된 저수지 운영시스템을 적용한 결과 강우종료 후에도 이수용량 확보가 가능하였으며, 하류하도의 피해을 최대한 주지 않는 범위 내에서 저수지의 수문조작이 가능하여 예당지의 홍수조절능력을 극대화할 수 있는 방안을 제시하였다.

  • PDF

A Dynamic Characteristics of the Tube Flow with the Variations of the Axially-Positioned Super-Circled Orifice Shape (유동방향의 초원형 오리피스 형상 변화가 관유동에 미치는 동특성 연구)

  • Kim, Youn J.;Lee, Sang-Sub
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.52-57
    • /
    • 1997
  • Dynamic characteristics of compressible flow fields in super-circled constricted tube have been studied numerically. By applying MacCormack's explicit scheme, time marching method with predictor/corrector step, Euler equation is solved to find characteristics of fluid flow in a constricted tube where a two-dimensional inviscid compressible flow is assumed. The effects of tube diameter and aspect ratios on the pressure variations are discussed extensively. The results of the developed numerical schemes are compared with those of commercial FLUENT code, and show a good agreement.

  • PDF

A Study on the Lubrication Characteristics of a Compensator System for Swash Plate Type Axial Piston Pump (사판식 액시얼 피스톤 펌프 가변용량 시스템의 윤활특성에 관한 연구)

  • Kim, Sin;Song, Ju-Hyun;Jung, Jae-Yeon;Lee, Du-Hyung
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1994.06b
    • /
    • pp.54-58
    • /
    • 1994
  • 본 연구에서는 가변용량형 사판식 액시얼 피스톤 펌프의 가변용량 시스템에 있어서 actuator piston의 가공정도와 실린더사이의 간극의 변화에 따른 응답성 및 누설용량에 끼치는 영향을 살펴보았다. 가변용량형 사판식 액시얼 피스톤 펌프는 사판의 각도를 조절함으로써 유량을 조절하게 된다. 사판의 각도조절은 actuator piston에 의해 행해지며, 가변용량부의 어느 설정압력에 도달하면, 이 actuator piston이 사판을 밀어 사판의 각도를 변화 시키게 된다. 지배방정식으로는 spool과 사판의 운동방정식과 각 chamber의 누설 유량이 있다. 이들 방정식을 \ulcorner으로써 각 부분의 운동을 해석할 수 있게 된다. 여기에서 해석이 어려운 부분은 각 계수들의 결정이며 simulation을 할 때는 이로한 계수들을 이론적으로 결정을 하게 되고, 실험을 통해 검증하도록 한다. 즉, 각 운동뷰의 감쇠계수와 각 오리피스를 통한 유량계수, 그리고 감쇠계수 등은 실험을 통해 검토한다. 실험을 통한 측정에서는 각 chamber의 압력은 각 chamber에 연결된 압력센서 3개에 의해 행해지며, 사판의 각도는 angle 센서에 의해 측정하게 된다. 그리고 actuator piston과 블럭 사이의 간극을 조절하여 누설계수를 변화시키며, 그 영향을 살펴보았다.

  • PDF

Preliminary Combustion Tests in Bi-Swirl Coaxial Injectors Using Gaseous Methane/Gaseous Oxygen Propellants (기체메탄/기체산소 추진제를 이용한 동축 와류형 분사기에서의 예비 연소실험)

  • Hwang, Donghyun;Bak, Sujin;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.70-80
    • /
    • 2019
  • Combustion tests using six bi-swirl coaxial injectors with different shapes and recess lengths were performed in a model combustion chamber capable of flame visualization. By utilizing gaseous methane and gaseous oxygen instead of actual propellants, the effects of injector design and experimental conditions on the flame structure and combustion stability were analyzed. It was found that not only the experimental conditions but also the injector geometry such as the recess length and orifice diameter had a considerable influence on the combustion stability. In addition, it was confirmed that the heat release pattern changed with the occurrence of combustion instability.

Unsteady Flow Model Including a Dam Operation Rule for Flood Control as Internal Boundary Condition (홍수시 댐 운영방안을 내부 경계조건으로 포함하는 부정류 계산모형)

  • Yu, Myoung-Kwan;Jun, Kyung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.12
    • /
    • pp.1043-1054
    • /
    • 2004
  • An unsteady flow model for channel network including various internal boundaries if developed. It is a multiply-connected network model based on the Preissmann's four-point scheme and the Newton-Raphson method, where looped double-sweep algorithm is used. The model is capable of simulating flow through hydraulic structures such as dams and submerged weirs. It can also simulate automatic reservoir operation method (Auto ROM) for flood control, that is to maintain a target water level, by incorporating the strategy to the unsteady flow model as internal boundary condition. The model is applied to the Han River system that includes the downstream reaches of Choongju dam and Hwacheon dam as well as the downstream reach of the Paldang dam. Roughness coefficient for the downstream reach of Choongju dam is estimated. Automatic ROM is presumed for the Paldang, Chungpyung, Euiam, and Choonchun dams. The model is tested using historical flood records, and the flood control strategy is successfully simulated.